Large-sized iatrogenic colonic perforation during diagnostic colonoscopy
Gastrointestinal Intervention
; : 94-97, 2018.
Article
de En
| WPRIM
| ID: wpr-739767
Bibliothèque responsable:
WPRO
ABSTRACT
SUMMARY OF EVENT: A 2 cm-sized colonic perforation occurred during diagnostic colonoscopy. Endoscopic closure was performed immediately using detachable snare and conservative management with intravenous antibiotics was followed for several days. However, abdominal computed tomography showed huge abscess and its connection to the sigmoid colon. The patient underwent segmental colectomy, which revealed the incomplete closure of perforated lesion with severe serosal fibrotic change. TEACHING POINT: Endoscopic treatment of large-sized colonic perforations should be undertaken with caution since the possibility of incomplete closure is high. For large-sized colonic perforations, early surgical treatment should be preferentially considered over endoscopic treatment.
Mots clés
Texte intégral:
1
Indice:
WPRIM
Sujet Principal:
Côlon sigmoïde
/
Coloscopie
/
Colectomie
/
Côlon
/
Abcès
/
Protéines SNARE
/
Antibactériens
Type d'étude:
Diagnostic_studies
Limites du sujet:
Humans
langue:
En
Texte intégral:
Gastrointestinal Intervention
Année:
2018
Type: