Analysis of X-ray signs to confirm the successful puncture in shoulder MR arthrography with low dose of contrast agent / 中华放射学杂志
Chinese Journal of Radiology ; (12): 568-572, 2020.
Article de Zh | WPRIM | ID: wpr-868315
Bibliothèque responsable: WPRO
ABSTRACT
Objective:To explore the value of X-ray signs with applying low dose of contrast agent to confirm successful puncture in direct shoulder MR arthrography.Methods:In total 669 patients who underwent shoulder MR arthrography in Peking University Third Hospital from January 2016 to August 2018 were retrospectively analyzed. All patients received the anterior approach puncture in shoulder arthrography. X-ray films were taken after 1-2 ml contrast agent was injected. Six X-ray signs of contrast agent distribution were recorded. MR arthrography findings were used to confirm whether the puncture was success. Kappa analysis was used to verify the consistency between each 2 signs. The accuracy rate of each X-ray sign to confirm the successful puncture was calculated. X-ray signs were paired to define the best diagnostic index of successful puncture.Results:Successful puncture was performed in arthrographies for all 669 cases .The displaying rates of six signs were as follows. Contrast agent distribution at overlapping humeral head away from the needle was 66.8% (447/669), in axillary recess was 64.7% (433/669), in glenohumeral space was 93.9% (628/669), in subscapular bursa was 69.8% (467/669), in sheath of long head tendon of biceps brachii (LHBT) was 1.9% (13/669), between LHBT and supraspinatus tendon was 17.2% (115/669). Consistency of each 2 signs was poor (Kappa<0.2), in which the poorest consistency was found between contrast agent overlapping humeral head away from the needle and contrast agent in glenohumeral space (Kappa=-0.115). With combining the above 2 signs, the accuracy rate for defining successful puncture was 100% (669/669).Conclusion:In direct shoulder arthrography by anterior approach, X-ray signs with low dose of contrast agent can be regard as the method to confirm successful puncture. The accuracy rate of the signs of contrast agent distribution at overlapping humeral head away from the needle or in glenohumeral space to define a successful puncture is 100%.
Texte intégral: 1 Indice: WPRIM Type d'étude: Diagnostic_studies langue: Zh Texte intégral: Chinese Journal of Radiology Année: 2020 Type: Article
Texte intégral: 1 Indice: WPRIM Type d'étude: Diagnostic_studies langue: Zh Texte intégral: Chinese Journal of Radiology Année: 2020 Type: Article