Your browser doesn't support javascript.
loading
Comparison of Plasma Components between Frozen Plasma and Fresh Frozen Plasma / 中国实验血液学杂志
Article Dans Zh | WPRIM | ID: wpr-880122
Responsable en Bibliothèque : WPRO
ABSTRACT
OBJECTIVE@#To compare the plasma components of frozen plasma (FP) and fresh frozen plasma (FFP).@*METHODS@#Twenty samples of FP and 20 samples of FFP from Beijing Red Cross Blood Center were randomly selected. Immediately after plasma melting, 12 plasma components including coagulation factor, fibrinolytic system and anticoagulation protein were detected, including activated partial thromboplastin time (APTT), prothrombin time (PT), coagulation factor Ⅷ (FⅧ) activity, coagulation factor Ⅴ (FⅤ) activity, fibrinogen(FIB) level, ADAMTS-13 activity, von Willebrand factor(vWF) activity, D-dimer (D-dimer, DD), fibrin degradation products (FDP), antithrombin (AT), protein C (PC), and protein S (PS). All these coagulation components between the two types of plasma were compared and analyzed.@*RESULTS@#Compared with FFP, APTT in FP was significantly prolonged(t=3.428, P0.05).@*CONCLUSION@#FP can substitute FFP in the treatment of some diseases, although it is lack of some coagulation factors and anticoagulation protein.
Sujets)
Texte intégral: 1 Indice: WPRIM Sujet Principal: Plasma sanguin / Coagulation sanguine / Tests de coagulation sanguine / Facteurs de la coagulation sanguine / Pékin Limites du sujet: Humans Pays comme sujet: Asia langue: Zh Texte intégral: Journal of Experimental Hematology Année: 2021 Type: Article
Texte intégral: 1 Indice: WPRIM Sujet Principal: Plasma sanguin / Coagulation sanguine / Tests de coagulation sanguine / Facteurs de la coagulation sanguine / Pékin Limites du sujet: Humans Pays comme sujet: Asia langue: Zh Texte intégral: Journal of Experimental Hematology Année: 2021 Type: Article