Inter-laboratory comparison result analysis of noise measurement in simulated workplace in three years / 中国职业医学
China Occupational Medicine
; (6): 310-314, 2020.
Article
de Zh
| WPRIM
| ID: wpr-881901
Bibliothèque responsable:
WPRO
ABSTRACT
OBJECTIVE: To analyze the influence of noise measuring skills by continuous inter-laboratory comparison among occupational hygiene technical service organizations. METHODS: The results of 68, 55 and 50 occupational hygiene technical service organizations(reference organizations) participating in the inter-laboratory comparison of workplace noise measurement in 2014, 2017 and 2018 respectively were collected. The measurement operation and the calculation of equivalent sound level were evaluated according to the GBZ/T 189.8-2007 Measurement of Physical Agents in Workplace--Part 8: Noise.The measured results were analyzed by z score evaluation method. RESULTS: The results of noise measurement field operation of the reference organizations in the year 2014, 2017 and 2018 show that the accuracy rates of instrument setting was 89.7%, 98.2% and 100.0%, the accuracy rates of measuring position were 52.9%, 81.8% and 94.0%, the accuracy rates of sound level meter holding were 54.4%, 80.0% and 92.0%, the accuracy rates of microphone pointing were 98.5%, 98.2% and 94.0%, and the accuracy rates of noise type recognition were 83.8%, 92.7% and 84.0%, respectively. Among them, the accuracy of instrument setting, measurement position and sound level meter holding showed an increasing trend year by year(P<0.01). The pass rates of measurement results were 91.2%, 94.5% and 88.0% in 2014, 2017 and 2018 respectively. The pass rates of equivalent sound level calculation were 73.5%, 92.7% and 88.0%. The pass rates of comprehensive evaluation were 70.6%, 89.1% and 80.0% respectively. Among them, the pass rates of equivalent sound level calculation and comprehensive evaluation in 2017 were higher than that in 2014(P<0.017). There was no significant difference in the three-year comprehensive assessment total pass rate between private organizations and non-private organizations(84.0 % vs 75.5%, P>0.05). There was no significant difference in the total pass rate of three-year comprehensive evaluation between non-Pearl-River-Delta organizations and Pearl-River-Delta organizations(70.3% vs 81.6%, P>0.05). CONCLUSION: Continuous inter-laboratory comparison in occupational hygiene technical service organizations is beneficial to improve on-site noise measure capability.
Texte intégral:
1
Indice:
WPRIM
langue:
Zh
Texte intégral:
China Occupational Medicine
Année:
2020
Type:
Article