Your browser doesn't support javascript.
loading
Multi-channel embolotherapy for type Ⅱ endoleak originating from lumbar arteries after endovascular abdominal aortic aneurysm repair / 中华普通外科杂志
Article de Zh | WPRIM | ID: wpr-933623
Bibliothèque responsable: WPRO
ABSTRACT
Objective:To evaluate multi-channel transcatheter embolotherapy for type Ⅱ endoleak originating from lumbar arteries after endovascular abdominal aortic aneurysm repair (EVAR).Methods:Data of 8 cases of type Ⅱ endoleak after EVAR from Oct 2017 to Nov 2020 at the Department of Vascular and Endovascular Surgery, Henan Provincial People's Hospital were retrospectively analyzed.Results:All patients who suffered from type Ⅱ endoleak that originated from lumbar arteries after EVAR were successfully treated with coils and mixture of Compant medical glue and iodipin through multi-channel. The technical success rate was 100%, the operative time was 80-150 min. Right lower limb dyskinesia occurred in 1 patient after operation, the symptom disappeared by anticoagulation and trophic neurotherapy for 2 months. Type Ⅱ endoleak didn't recur in all patients, and no mortality during the 4-38(14.1) months follow-up period.Conclusion:Multi-channel transcatheter embolotherapy has definite effects for the treatment of type Ⅱ endoleak from lumbar arteries after EVAR, with high technical feasibility, few perioperative complications, low mortality among other advantages. The results of short and medium term are satisfactory.
Mots clés
Texte intégral: 1 Indice: WPRIM langue: Zh Texte intégral: Chinese Journal of General Surgery Année: 2022 Type: Article