Validación externa y reproducibilidad del cuestionario PUMA para el diagnóstico de EPOC en una población latinoamericana: validación externa del cuestionario PUMA / External validation and reproducibility of the PUMA questionnaire for the diagnosis of COPD in a Latin American population: external validation of the PUMA questionnaire
Rev. chil. enferm. respir
; Rev. chil. enferm. respir;38(1): 11-19, mar. 2022. ilus, tab
Article
em Es
| LILACS
| ID: biblio-1388167
Biblioteca responsável:
CL1.1
RESUMEN
Resumen El uso de escalas de predicción clínica puede incrementar la detección temprana de enfermedad pulmonar obstructiva crónica (EPOC). Su rendimiento en población latinoamericana ha sido pobremente estudiado. Nuestro objetivo fue determinar la validez y reproducibilidad del cuestionario PUMA, como herramienta de tamización en atención primaria en población colombiana, mediante un estudio tipo corte transversal; donde se establecieron las características operativas del cuestionario, área bajo la curva de características operativas del receptor (ACOR) y el mejor punto de corte para esta población. 1.980 sujetos fueron incluidos en el análisis. La prevalencia de EPOC correspondió a 18,9%. La capacidad discriminatoria del cuestionario fue de 0,69 (IC95% 0,66-0,72), para un punto de corte óptimo mayor de 5, con una sensibilidad del 60%, especificidad 66% y un valor predictivo negativo de 88%. La escala PUMA para tamizaje de pacientes en riesgo de EPOC tiene una capacidad discriminatoria moderada y una excelente reproducibilidad en la población estudiada.
ABSTRACT
The use of clinical prediction scales may increase the early detection of chronic obstructive pulmonary disease (COPD). The performance characteristics of these scales in the Latin American population is poorly studied. We aimed to evaluate validity and reproducibility of PUMA questionnaire as a screening tool in primary care in a Colombian population. A cross-sectional study was performed. Operational characteristics of the questionnaire, the area under the received operator curve (AUROC), and the best cut-off point of the score were calculated. 1,980 individuals were included in this analysis. Prevalence of COPD was 18.9%. AUROC of the questionary was 0.69 (CI95% 0.66-0.72), with an optimal cut-off point greater than 5 (sensitivity 60%, specificity 66%); predictive negative value was 88%. PUMA's scale for the screening of patients at risk of COPD has a moderate accuracy and an excellent reproducibility in the studied population.
Palavras-chave
Texto completo:
1
Índice:
LILACS
Assunto principal:
Atenção Primária à Saúde
/
Inquéritos e Questionários
/
Doença Pulmonar Obstrutiva Crônica
Tipo de estudo:
Diagnostic_studies
/
Observational_studies
/
Prevalence_studies
/
Prognostic_studies
/
Risk_factors_studies
/
Screening_studies
Limite:
Adult
/
Aged
/
Female
/
Humans
/
Male
País/Região como assunto:
America do sul
/
Colombia
Idioma:
Es
Revista:
Rev. chil. enferm. respir
Assunto da revista:
PNEUMOLOGIA
Ano de publicação:
2022
Tipo de documento:
Article