Your browser doesn't support javascript.
loading
Influencia de la interpolación sobre la calidad de imágenes de microscopía celular / Influence of Interpolation on the Quality of Cell Microscopy Images
Coca Rodriguez, Arianny; Lorenzo Ginori, Juan Valentín.
  • Coca Rodriguez, Arianny; Centro Universitario Municipal de Placetas. Universidad Central Marta Abreu. Villa Clara. CU
  • Lorenzo Ginori, Juan Valentín; Centro de Investigaciones de la Informática. Facultad de Matemática, Física y Computación. Universidad Central Marta Abreu. Villa Clara. CU
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1408520
RESUMEN
El presente trabajo tiene el propósito de analizar, para el caso particular de imágenes de microscopía celular de eritrocitos de sangre humana, en qué medida puede influir en la calidad de la imagen la aplicación de métodos de interpolación para mejorar la resolución de esta y con qué métodos se podrían obtener resultados satisfactorios. Se aplicaron para su comparación tres métodos de interpolación a las imágenes a color seleccionadas splines cúbicos, bicúbico y bilineal y se evaluó la eficiencia computacional de estos. Se utilizaron dos factores de reducción de la resolución (2 y 4) por filas y columnas de la imagen digital. Las medidas utilizadas para valorar la calidad de las imágenes interpoladas fueron la relación señal-ruido y el error medio cuadrático, cuyos valores fueron procesados estadísticamente mediante las pruebas de Friedman y de Wilcoxon, esta última como test post-hoc. Los resultados permiten recomendar el método bicúbico de interpolación como el más favorable para este tipo de imágenes ya que fue el de mejor comportamiento entre los utilizados(AU)
ABSTRACT
The present work has the purpose of analyzing, for the particular case of cell microscopy images of erythrocytes from human blood, to what extent the application of interpolation methods to improve the image resolution can influence the image quality and with which methods satisfactory results might be obtained. Three interpolation methods were applied for their comparison to the selected color images cubic splines, bicubic and bilinear and their computational efficiency was also evaluated. Two resolution reduction factors (2 and 4) were used for rows and columns of the digital image. The measures used to assess the quality of the interpolated images were the signal-to-noise ratio and the mean square error, whose values were statistically processed using the Friedman and Wilcoxon tests, the latter as a post-hoc test. The results make it possible to recommend the bicubic interpolation method as the most favorable for this type of images since it was the one with the best performance among those used(AU)
Assuntos

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Aplicações da Informática Médica / Microscopia Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. cuba. inform. méd Assunto da revista: Informática Médica / Serviços de Saúde Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Cuba Instituição/País de afiliação: Centro Universitario Municipal de Placetas/CU / Centro de Investigaciones de la Informática/CU

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: LILACS (Américas) Assunto principal: Aplicações da Informática Médica / Microscopia Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. cuba. inform. méd Assunto da revista: Informática Médica / Serviços de Saúde Ano de publicação: 2021 Tipo de documento: Artigo País de afiliação: Cuba Instituição/País de afiliação: Centro Universitario Municipal de Placetas/CU / Centro de Investigaciones de la Informática/CU