Your browser doesn't support javascript.
loading
Influence of Cavity Dimensions on Microleakage of Two Bulk-Fill Composite Resins
Naghili, Armaghan; Yousefi, Navid; Zajkani, Elham; Ghasemi, Amir; Torabzadeh, Hassan.
Afiliação
  • Naghili, Armaghan; s.af
  • Yousefi, Navid; s.af
  • Zajkani, Elham; s.af
  • Ghasemi, Amir; s.af
  • Torabzadeh, Hassan; s.af
Pesqui. bras. odontopediatria clín. integr ; 19(1): 4628, 01 Fevereiro 2019. tab
Article em En | LILACS, BBO | ID: biblio-998246
Biblioteca responsável: BR1264.1
ABSTRACT

Objective:

To evaluate the effect of cavity dimensions on the amount of microleakage in two different types of bulk-fill composite resins. Material and

Methods:

Forty class II cavities were prepared in the mesial and distal surfaces of human molars without any carious lesions. The samples were divided into 4 groups (n=10) Group 1 cavities with 3 mm of buccolingual width (known as the smaller cavity), filled with Tetric N-Ceram Bulk Fill composite resin; Group 2 cavities with 6 mm of buccolingual width (larger cavity), filled with Tetric N-Ceram Bulk Fill composite resin; Group 3 cavities with 3 mm of buccolingual width, filled with X-Tra Base composite resin; and Group 4 cavities with 6 mm of buccolingual width, filled with X-Tra Base composite. After the specimens were thermocycled for 500 cycles at 5/55°C, they were immersed in 1% methylene blue for 24 hours, and then cut into sections mesiodistally in the longitudinal axis of each tooth. Then, the samples were scored regarding the amount of dye penetration in two occlusal and gingival areas under a stereomicroscope (x32). Data was submitted to Kruskal- Wallis and Mann-Whitney tests.

Results:

The highest degrees of microleakage in larger cavities filled with X-Tra Base among the four groups. There was a significant statistic difference (p=0.012) between large and small cavities filled with X-Tra Base (Groups 3 and 4); however, there was no significant difference between the two cavity sizes of Tetric N-Ceram Bulk-filled groups.

Conclusion:

Microleakage of composite resins depends on the dimension of the cavity and the type of composite resin used.
Assuntos
Palavras-chave

Texto completo: 1 Índice: LILACS Assunto principal: Resinas Compostas / Preparo da Cavidade Dentária / Infiltração Dentária Tipo de estudo: Evaluation_studies País/Região como assunto: Asia Idioma: En Revista: Pesqui. bras. odontopediatria clín. integr Assunto da revista: ODONTOLOGIA Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Índice: LILACS Assunto principal: Resinas Compostas / Preparo da Cavidade Dentária / Infiltração Dentária Tipo de estudo: Evaluation_studies País/Região como assunto: Asia Idioma: En Revista: Pesqui. bras. odontopediatria clín. integr Assunto da revista: ODONTOLOGIA Ano de publicação: 2019 Tipo de documento: Article