Modified Duhamel procedure for Hirschsprung's disease: an analysis of 24 cases
JSP-Journal of Surgery Pakistan International. 2002; 7 (3): 2-5
em En | IMEMR | ID: emr-59917
Biblioteca responsável: EMRO
ABSTRACT
A Prospective analytic study of 24 case of Hirschsprung's disease [H.D] was conduct over a period of two years first January 2000 to December 2001 in the Department of Paediatric Surgery, Mayo Hospital, Lahore, to evaluate the outcome of the patients after modified Duhamel pull through procedure. The results showed that Modified Duhamel procedure with the help of Mechanical stapling device had minimum complications with no mortality and were consistent with other studies showing that Modified Duhamel procedure is quite safe for Hirschsprung's Disease
Assuntos
Buscar no Google
Índice: IMEMR Assunto principal: Procedimentos Cirúrgicos Operatórios / Grampeamento Cirúrgico Limite: Female / Humans / Male Idioma: En Revista: J. Surg. Pak. Int. Ano de publicação: 2002