Fraturas da extremidade distal da tíbia tratadas pela haste intramedular e placa em ponte: comparação do tempo de exposição à radiação nos dois métodos / Fractures of distal third extremity of the tibia treated with intramedullary nail and bridge plate: comparison of radiation exposure time in the two methods
Rev. bras. ortop
; 45(2): 132-135, 2010. tab
Article
em Pt
| LILACS
| ID: lil-547909
Biblioteca responsável:
BR26.1
RESUMO
OBJETIVO:
Comparar o tempo de exposição à radiação nos pacientes com fratura do terço distal da tíbia tratados com haste intramedular e placa em ponte.MÉTODOS:
Em 33 fraturas foram utilizadas hastes intramedulares e em 41, placas em ponte. No grupo haste, segundo a classificação AO, 14 pacientes apresentavam fraturas do tipo A, 15 do tipo B e quatro, do tipo C. Doze pacientes sofreram fraturas fechadas e 21, expostas. No grupo placa, 10 pacientes apresentavam fraturas do tipo A, 22 do tipo B e nove do tipo C. Vinte e sete pacientes sofreram fraturas fechadas e 14 expostas.RESULTADOS:
Observou-se que existe diferença significativa no tempo de exposição à radiação entre pacientes tratados com haste e placa (p = 0,0001). O grupo tratado com haste apresentou tempo de exposição à radiação significativamente maior que o grupo com placa. Quando comparado o tipo de fratura (A, B e C), observou-se que não existe diferença significativa no tempo de exposição à radiação quando utilizada a técnica de haste (p = 0,19) e placa (p = 0,80).CONCLUSÃO:
Fraturas do terço distal da tíbia tratadas com haste intramedular apresentam um tempo de exposição à radiação significativamente maior do que as fraturas tratadas com placa em ponte, independente do tipo de fratura.ABSTRACT
OBJECTIVE:
To compare the exposure time to radiation in patients with distal third fractures of the tibia treated with intramedullary nail and bridge plate.METHODS:
In 33 fractures intramedullary nails were used, and in 41 fractures plates were used. In the intramedullary nail group, according to the AO classification, 14 patients had type A fractures, 15 patients had type B fractures and four had type C fractures. Twelve patients had closed fractures and 21 had open fractures. In the plate group, 10 patients had type A fractures, 22 patients had type B fractures and nine had type C fractures. 27 patients had closed fractures and 14 had open fractures.RESULTS:
A significant difference was observed in exposure time to radiation between the patients treated with the intramedullary nail and the plate (p = 0.0001). The group treated with the intramedullary nail had a significantly higher exposure time to the radiation than the group treated with the plate. Comparing the type of fracture (A, B and C), it was observed that there is no considerable difference in exposure time to radiation between the intramedullary nail technique (p = 0.19) and the plate technique (p = 0.80).CONCLUSION:
Fractures of distal third of the tibia treated with intramedullary nail show considerably higher exposure time to radiation than fractures treated with the bridge plate, independent of fracture type.Palavras-chave
Texto completo:
1
Índice:
LILACS
Assunto principal:
Fraturas da Tíbia
/
Estudos de Casos e Controles
/
Fixação Intramedular de Fraturas
Tipo de estudo:
Observational_studies
Limite:
Adolescent
/
Adult
/
Female
/
Humans
/
Male
Idioma:
Pt
Revista:
Rev. bras. ortop
/
Rev. bras. ortop. (Online)
/
Revista brasileira de ortopedia (Impresso)
Assunto da revista:
ORTOPEDIA
Ano de publicação:
2010
Tipo de documento:
Article