Efeito de cerâmicas odontológicas na passagem da luz emitida por aparelhos fotoativadores / Effect of dental ceramics on the transmittance of light emitted by curing units
Rev. Assoc. Paul. Cir. Dent
; 67(4): 287-291, out.-dez. 2013. ilus, tab
Article
em Pt
| LILACS, BBO
| ID: lil-707535
Biblioteca responsável:
BR97.1
RESUMO
Este estudo avaliou a influência de dois tipos de cerâmicas odontológicas (óxido de zircônio e dissilicato de lítio) na transmitância da luz emitida por diferentes aparelhos fotoativadores. Discos com 1 mm de espessura e 10 mm de diâmetro foram preparados a partir dos materiais restauradores indiretos IPS e.Max Zircad (lvoclar Vivadent) e IPS e.Max (lvoclar Vivadent). Sobre os materiais protéticos foi aplicada a cerâmica à base de nanofluorapatita (IPS e.Max Ceram, Ivociar vivadent), com 1 mm de espessura. Cinco diferentes aparelhos fotoativadores foram testados Arc Light 11 (AirTechniques), ColtoLux LED (Colténe Whaledent), Elipar Free Light 2 (3M ESPE), Astralis 10 (lvoclar Vivadent) e Ultralume 5 (Ultradent), sendo esse último utilizado no modo normal, apenas com luz azul ou luz violeta. A irradiância através dos diferentes materiais restauradores foi mensurada com um espectroradiômetro (DAS 2100, Labsphere) associado a um software especifico (Spectra Suite, Ocean Optics). Os dados foram submetidos à analise de variância de 2 fatores e teste de T ukey (ps;O,05). A luz emitida pelo aparelho arco de plasma (Arc Light 11) mostrou maior passagem através dos materiais indiretos estudados, enquanto a luz violeta emitida pelo aparelho Ultralume 5 foi a mais bloqueada entre os aparelhos. A zircônia permitiu maior passagem de luz quando comparada ao dissilicato de lítio. Os materiais restauradores indiretos estudados apresentaram comportamentos distintos com relação à passagem de luz. O tipo de aparelho fotoativador influenciou a irradiância através dos diferentes materiais restauradores.
ABSTRACT
This study evaluated the influence of different types of restorative indirect materiais (zirconium oxide and lithium disilicate) in transmittance of light emitted by different types of curing units. Discs with 1 mm thickness and 10 mm dia meter were prepared from the indirect restorative materiais IPS e.max ZirCAD (Ivoclar Vivadent) and IPS e.max (Ivoclar Vivadent). A nanofluorapatite ceramic (IPS e.max, Ivoclar Vivadent) was applied over theindirect materiais with 1 mm thickness. Five different light curing units were tested Arc Light II (Air Technologies), ColtoLux LED (Colténe Whaledent), Elipar Free Light 2 (3M ESPE), Astralis 10 (Ivoclar Vivadent) and Ultralume 5 (Ultradent), which was used in regular mode, only light blue and only violet. The Irradiance through different restorative materiais was measured using a spectroradiometer (DAS 2100, Labsphere) associated with a specific software (Spectra Suite, Ocean Optics). Data were analyzed by two-way analysis of variance and Tukey test (ps;O,05). The plasma are curing unit (Arc Light 11) showed the highest irradiance values through different restorative materiais, while the light source Ultralume 5, violet mode, showed the lowest irradiance values through different restorative materiais. The zirconia allowed higher light intensity passed through it when compared to lithium disilicate. The indirect restorative materiais tested showed distinct properties regarding the transmittance of light. Type of curing unit significantly influenced the Irradiance through different restorative materiais.
Buscar no Google
Índice:
LILACS
Assunto principal:
Materiais Dentários
/
Polimerização
/
Luz
Idioma:
Pt
Revista:
Rev. Assoc. Paul. Cir. Dent
Assunto da revista:
ODONTOLOGIA
Ano de publicação:
2013
Tipo de documento:
Article