Your browser doesn't support javascript.
loading
Estabilidad de la adenosina deaminasa en diferentes medios de transporte del líquido pleural / Adenosine deaminase stability in pleural effusions defferent means of transport
Suárez Blandenier, Liliana Elizabeth; Brito, Andreina A; Canchica, Liz Mariela.
Afiliação
  • Suárez Blandenier, Liliana Elizabeth; Hospital General del Este Dr. Domingo Luciani. Caracas. VE
  • Brito, Andreina A; Hospital General del Este Dr. Domingo Luciani. Caracas. VE
  • Canchica, Liz Mariela; Hospital General del Este Dr. Domingo Luciani. Caracas. VE
Gac. méd. Caracas ; 121(2): 149-155, abr.-jun. 2013. tab, graf
Article em Es | LILACS | ID: lil-718916
Biblioteca responsável: VE1.1
RESUMEN
La determinación de los niveles de la adenosina deaminasa en el líquido pleural es sensible y específica para la tuberculosis pleural. La adenosina deaminasa en el líquido pleural disminuye con el tiempo a temperatura ambiente. El objetivo de este estudio es demostrar si existe diferencia en los valores de la adenosina deaminasa en líquidos pleurales en cuatro medios diferentes de transporte (hielo, citrato de sodio, heparina y ninguna sustancia, química añadida). Se determinaron los niveles de la enzima en ochenta y ocho (88) muestras de líquido pleural procedentes de 22 pacientes con derrames pleurales no diagnosticados. Se demostró la concordancia diagnóstica entre los diferentes medios de transporte. No se demostró diferencia significativa entre los niveles de la adenosina deaminasa en cada una de los diferentes medios de transporte hasta dos (2) horas posterior a su recolección. Se recomienda enviar las muestras de líquido pleural con el conservativo adecuado o con ácido etilen diamino tetracético de rutina en nuestro país
ABSTRACT
The determination of the levels of adenosine deaminase in pleural fluid is sensitive and specific for pleural tuberculosis. Adenosine deaminase in pleural fluid decreases over time at room temperature. The objective of this study is to demostrate if there is difference on the average values of adenosine deaminasa in pleural fluids in four different means of transport (ice, sodium citrate, heparin and no added chemical substance). The levels of the enzyme in eighty-eight (88) pleural fluid samples from 22 patients with diagnosed pleural effusions were determined. We demonstrated diagnostic concodance between the differents modes of transport. No significant difference is between the levels of adenosine deaminase in each of the different means of transport up to two (2) hours after collection. It is recommended to send by routine in our country samples of pleural fluid with the right conservative or Acid etilen diamino tetracetic
Assuntos
Palavras-chave
Buscar no Google
Índice: LILACS Assunto principal: Derrame Pleural / Tuberculose Pleural / Heparina / Meios de Cultura / Inibidores de Adenosina Desaminase / Gelo Tipo de estudo: Evaluation_studies Limite: Aged / Aged80 Idioma: Es Revista: Gac. méd. Caracas Assunto da revista: MEDICINA Ano de publicação: 2013 Tipo de documento: Article
Buscar no Google
Índice: LILACS Assunto principal: Derrame Pleural / Tuberculose Pleural / Heparina / Meios de Cultura / Inibidores de Adenosina Desaminase / Gelo Tipo de estudo: Evaluation_studies Limite: Aged / Aged80 Idioma: Es Revista: Gac. méd. Caracas Assunto da revista: MEDICINA Ano de publicação: 2013 Tipo de documento: Article