Avaliação histopatológica da cápsula posterior associada ao implante de lente intraocular com superfície modificada com plasma de flúor e polietilenoglicol em coelhos / Histopathological evaluation of posterior capsule associated with intraocular lens implant with modified surface using fluorine and poliethilene glycol plasma in rabbits
Arq. bras. med. vet. zootec
; Arq. bras. med. vet. zootec. (Online);67(5): 1295-1303, tab, graf
Article
em Pt
| LILACS
| ID: lil-764442
Biblioteca responsável:
BR68.1
RESUMO
O objetivo deste estudo foi avaliar o efeito do tratamento da superfície de lentes intraoculares acrílicas utilizando-se plasma de flúor ou polietilenoglicol na prevenção da opacidade de cápsula posterior. Foram analisados 40 olhos de coelhos, submetidos à cirurgia de facoemulsificação e distribuídos em quatro grupos experimentais (n=10), sendo estes grupo controle, coelhos sem implante de lente intraocular; grupo com lente intraocular tratada com plasma de polietilenoglicol; grupo com lente intraocular tratada com plasma de flúor; e grupo com lente intraocular comercial. As cápsulas posteriores das lentes dos grupos foram avaliadas por meio de análise histopatológica (morfometria e imuno-histoquímica). Os grupos com lente intraocular tratada com polietilenoglicol e com lente intraocular comercial apresentaram menor espessura da cápsula posterior na avaliação inicial (12 semanas) em relação ao grupo controle. No período final de avaliação (6 meses), os tratamentos da superfície da lente intraocular à base de plasma de flúor e polietilenoglicol não reduziram o desenvolvimento das alterações histológicas associadas à opacidade de cápsula posterior. O tratamento das superfícies das lentes intraoculares com plasma de flúor e polietilenoglicol pode ser realizado como adjuvante na prevenção da opacidade de cápsula posterior, pois não causa alterações na morfologia da lente após facoemulsificação.
ABSTRACT
The aim of this study was to evaluate the effect of surface treatment of acrylic intraocular lens using Fluorine plasma or polyethylene glycol in the prevention of posterior capsule opacification. Forty rabbit eyes that underwent phacoemulsification were analyzed and distributed into four experimental groups (n=10) Control group, composed of rabbits without intraocular lens implantation; intraocular lens group treated with Polyethylene glycol plasma, intraocular lens group treated with Fluoride plasma, and commercial intraocular lens group. The posterior capsule of the lens was evaluated by histopathological analysis, including morphometric and immunohistochemical studies. Groups with intraocular lens treated with polyethylene glycol and commercial intraocular lens presented thinner posterior capsule at initial assessment (12 weeks) compared to the control group. At the end of the evaluation (six months), the treatment of surface intraocular lens with fluorine and polyethylene glycol plasma did not reduce the development of histological changes associated with posterior capsule opacification. The surface treatment of the intraocular lens with Fluoride and Polyethylene glycol can be performed as an adjuvant in preventing posterior capsule opacification, because it does not cause changes in the morphology of lens after phacoemulsification surgery.
Palavras-chave
Texto completo:
1
Índice:
LILACS
Assunto principal:
Facoemulsificação
/
Olho
/
Opacificação da Cápsula
/
Lentes Intraoculares
Tipo de estudo:
Risk_factors_studies
Limite:
Animals
Idioma:
Pt
Revista:
Arq. bras. med. vet. zootec
/
Arq. bras. med. vet. zootec. (Online)
Assunto da revista:
MEDICINA VETERINARIA
Ano de publicação:
2015
Tipo de documento:
Article
/
Project document