Acurácia diagnóstica da onda P nas derivações de Lewis/Gallop para detecção das sobrecargas atriais / Diagnostic accuracy of the P wave in the Lewis and Gallop Leads for atrial enlargement detection
Miranda, Carlos Henrique; Gerolim, Gustavo P; Gali, Ana Marta Salgado; Pazin-Filho, Antônio.
Afiliação
  • Miranda, Carlos Henrique; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Departamento de Clínica Médica. Ribeirão Preto. BR
  • Gerolim, Gustavo P; Universidade de São Paulo. Hospital das Clínicas. Serviço de Ecocardiografia. Ribeirão Preto. BR
  • Gali, Ana Marta Salgado; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Departamento de Clínica Médica. Ribeirão Preto. BR
  • Pazin-Filho, Antônio; Universidade de São Paulo. Faculdade de Medicina de Ribeirão Preto. Departamento de Clínica Médica. Ribeirão Preto. BR
Int. j. cardiovasc. sci. (Impr.) ; 28(5): 417-423, set.-out. 2015. tab
Article em Pt | LILACS | ID: lil-786808
Biblioteca responsável: BR44.1
RESUMO
Fundamentos A acurácia diagnóstica (AD) do eletrocardiograma (ECG) convencional para detecção das sobrecargas atriais (SA) é baixa. As derivações de Lewis (L) e Gallop (G) permitem melhor visualização da onda P no ECG.

Objetivo:

Verificar se os parâmetros da onda P nas derivações de Lewis e Gallop aumentam a acurácia diagnósticados critérios de SA do ECG convencional.

Métodos:

As características da onda P nas derivações de L e G foram padronizadas em 27 indivíduos saudáveis. Considerou-se como limite de normalidade o percentil 99 para esses parâmetros. Esses novos critérios foram avaliados em 117 pacientes através do ECG convencional e das derivações de L e G. As dimensões dos átrios pelo ecocardiograma foram consideradas padrão-ouro para definição das SA. Para determinação da AD de cada parâmetro utilizou-se a área sob a curva (AUC) ROC (receiver operating characteristic).

Resultados:

ECG convencional apresentou baixa AD para detecção das SA. O índice de Morris foi o único que mostrou AD significativa AUC 0,57 (95%IC 0,48-0,66); p=0,03. A inclusão da onda P>100 ms (L e G) não aumentou a AD para detecção de SA esquerda em relação aos critérios tradicionais AUC 0,58 (95%IC 0,50-0,65)vs. AUC 0,57 (95%IC 0,49-0,65); p=0,80. A inclusão de onda P com amplitude >2mm (L) e/ou >3mm (G) tambémnão aumentou a AD para detecção de SA direita AUC 0,53 (95%IC 0,46-0,61) vs. AUC 0,53 (95%IC 0,45-0,60); p=0,31.

Conclusão:

A inclusão da avaliação da onda P nas derivações acessórias de L e G não resultou em incremento da AD para detecção das SA.
ABSTRACT

Background:

The diagnostic accuracy (DA) of the conventional electrocardiogram (ECG) for detecting atrial enlargement (AE) is low. Lewis (L) and Gallop (G) enable better viewing the P wave in the ECG.

Objective:

Checking whether the P wave parameters in the leads of Lewis and Gallop increase the diagnostic accuracy of the conventional ECG AE criteria.

Methods:

The P wave characteristics in the L and G leads were standardized in 27 healthy individuals. The percentile of 99 was considered as limit of normality for those parameters. These new criteria were evaluated in 117 patients through conventional ECG and the L and G leads. The atrial sizes under the echocardiogram were considered as golden standard for defining the AE. The areaunder the ROC (receiver operating characteristic) curve (AUC) was used for determining the DA of each parameter.

Results:

Conventional ECG presented low DA for detecting the AE. Morris index was the only showing significant DA AUC 0.57 (95%CI0.48-0.66); p=0.03. The inclusion of the P wave >100ms (L and G) has not increased the DA for detecting left AE compared to the traditional criteria AUC 0.58 (95%CI 0.50-0.65) vs. AUC 0.57 (95%CI 0.49-0.65); p=0.80. Including P wave with amplitude >2 mm (L) and/or>3 mm (G) has not increased DA for detecting right AE either AUC 0.53 (95%CI 0.46-0.61) vs. AUC 0.53 (95%CI 0.45-0.60); p=0.31.

Conclusion:

Including the P wave in the accessory leads of L and G did not result in increment of DA for detecting AE.
Assuntos
Palavras-chave

Texto completo: 1 Índice: LILACS Assunto principal: Função do Átrio Esquerdo / Função do Átrio Direito / Técnicas e Procedimentos Diagnósticos / Eletrocardiografia Tipo de estudo: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male Idioma: Pt Revista: Int. j. cardiovasc. sci. (Impr.) Assunto da revista: CARDIOLOGIA Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Índice: LILACS Assunto principal: Função do Átrio Esquerdo / Função do Átrio Direito / Técnicas e Procedimentos Diagnósticos / Eletrocardiografia Tipo de estudo: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male Idioma: Pt Revista: Int. j. cardiovasc. sci. (Impr.) Assunto da revista: CARDIOLOGIA Ano de publicação: 2015 Tipo de documento: Article