Role of span length in the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniques
The Journal of Advanced Prosthodontics
; : 124-129, 2017.
Article
em En
| WPRIM
| ID: wpr-117653
Biblioteca responsável:
WPRO
ABSTRACT
PURPOSE: This study evaluated the effect of span length on the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniques. MATERIALS AND METHODS: Models with two solid abutment analogs at different inter-abutment distances were digitized using a laboratory scanner. Frameworks of two-, three-, and four-unit fixed prostheses were designed by a computer. Six dots with a diameter of 0.2 mm were preset on the surface of each framework. A total of 54 implant-supported cobalt chromium frameworks were fabricated by milling, selective laser melting (SLM), and cast techniques. The frameworks were scanned and exported as Stereolithography files. Distances between two dots in X, Y, and Z coordinates were measured in both the designed and fabricated frameworks. Marginal gaps between the framework and the abutments were also evaluated by impression replica method. RESULTS: In terms of distance measurement, significant differences were found between three- and four-unit frameworks, as well as between two- and four-unit frameworks prepared by milling technique (P<.05). Significant differences were also noted between two- and three-unit frameworks, as well as between two- and four-unit frameworks prepared by cast technique (P<.05). The milling technique presented smaller differences than the SLM technique, and the SLM technique showed smaller differences than the cast technique at any unit prostheses (P<.05). Evaluation with the impression replica method indicated significant differences among the span lengths for any fabrication method (P<.05), as well as among the fabrication methods at any unit prostheses (P<.05). CONCLUSION: The adaptation of implant-supported cobalt chromium frameworks was affected by the span length and fabrication method.
Palavras-chave
Texto completo:
1
Índice:
WPRIM
Assunto principal:
Próteses e Implantes
/
Cromo
/
Cobalto
/
Congelamento
/
Métodos
Idioma:
En
Revista:
The Journal of Advanced Prosthodontics
Ano de publicação:
2017
Tipo de documento:
Article