Your browser doesn't support javascript.
loading
A Study to Verify the Stability of Currently Stored Blood Donor Samples (A First Year Study) / 대한수혈학회지
Article em Ko | WPRIM | ID: wpr-160020
Biblioteca responsável: WPRO
ABSTRACT
BACKGROUND: The Korean Red Cross (KRC) has stored blood donor samples for 10 years under -20degrees C since 2004. These samples have been used for investigating transfusion related infections and for Look-back studies. We designed an experimental scheme to verify the stability of stored blood samples. METHODS: We collected and prepared samples such as blood donor samples (HBV, HCV, HIV nucleic acid positive; n=90), the HIV infected patient samples (n=20), the WHO nucleic acid international standards serologic positive samples (HBsAg, anti-HCV, anti-HIV; n=120) and the negative samples (n=20). The samples were aliquoted in cryo tubes with volumes of 0.5~5 mL and they were stored at -20~-30degrees C and -70~-80degrees C. We used enzyme immunoassay, chemiluminescence immunoassay and quantitative PCR for the base line and the follow up studies. The linear mixed statistical model using SAS 9.1 for windows was used for statistical analysis. RESULTS: The results of the baseline test of the stored samples showed a variable range of viral load (10(1)~10(7) IU/mL or copies/mL) and optical density (S/CO 3.0~500). The results of the stored samples after 6 month (n=82) did not show any significant differences compared to the baseline data for the viral loads (P>0.05) and the qualitative serologic tests. CONCLUSION: We established an experimental scheme to verify the stability of the stored blood donor samples. From now on, the stability of the stored samples is going to be monitored by every 6 month for 10 years.
Assuntos
Palavras-chave
Texto completo: 1 Índice: WPRIM Assunto principal: Fenotiazinas / Cruz Vermelha / Doadores de Sangue / Imunoensaio / Testes Sorológicos / Reação em Cadeia da Polimerase / Seguimentos / Modelos Estatísticos / Técnicas Imunoenzimáticas / HIV Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Qualitative_research / Risk_factors_studies Limite: Humans Idioma: Ko Revista: Korean Journal of Blood Transfusion Ano de publicação: 2009 Tipo de documento: Article
Texto completo: 1 Índice: WPRIM Assunto principal: Fenotiazinas / Cruz Vermelha / Doadores de Sangue / Imunoensaio / Testes Sorológicos / Reação em Cadeia da Polimerase / Seguimentos / Modelos Estatísticos / Técnicas Imunoenzimáticas / HIV Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Qualitative_research / Risk_factors_studies Limite: Humans Idioma: Ko Revista: Korean Journal of Blood Transfusion Ano de publicação: 2009 Tipo de documento: Article