Your browser doesn't support javascript.
loading
Long-term Surgical Outcomes of the Multi-purpose Conical Porous Synthetic Orbital Implant
Article em En | WPRIM | ID: wpr-229272
Biblioteca responsável: WPRO
ABSTRACT

PURPOSE:

We present clinical results of the use of the multipurpose conical porous synthetic orbital implant (MCOI) in surgical procedures of evisceration, enucleation, and secondary enucleation in ophthalmology patients.

METHODS:

A retrospective review was performed of 59 eyes in which conical implants were used, including 36 cases of eviscerations, 11 enucleations, and 9 secondary enucleations. In all of the cases, the follow-up period was greater than six months between 2004 and 2013. The results focus on documenting surgical findings, as well as postoperative complications among patients.

RESULTS:

Superior sulcus deformities were found in six eyes (10.2% of conical implant patients), and two eyes received additional surgical interventions to correct the deformities (3.4%). Blepharoptosis was found in four eyes (6.8%), two of which received upper eyelid blepharoplasty (3.4%). Fornix shortening was reported in only one eye (1.7%). Forty-one eyes had a satisfactory cosmetic appearance after the final prosthetic fitting of conical implants (69.5%). The most frequent postoperative complication was orbital implant exposure, which seemed to occur when the preoperative status of the conjunctiva, Tenon's capsule, and sclera preservation were poor in the eyes of the patients.

CONCLUSIONS:

There was a lower incidence of blepharoptosis and fornix shortening with the MCOI in comparison to spherical implants, while the incidence of orbital implant exposure was similar with the MCOI in comparison to other types of orbital implants. In addition, the MCOI may have advantages with respect to postoperative cosmetic outcomes.
Assuntos
Palavras-chave
Texto completo: 1 Índice: WPRIM Assunto principal: Complicações Pós-Operatórias / Fatores de Tempo / Enucleação Ocular / Incidência / Estudos Retrospectivos / Seguimentos / Resultado do Tratamento / Evisceração do Olho / Implantação de Prótese / Implantes Orbitários Tipo de estudo: Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male País/Região como assunto: Asia Idioma: En Revista: Korean Journal of Ophthalmology Ano de publicação: 2015 Tipo de documento: Article
Texto completo: 1 Índice: WPRIM Assunto principal: Complicações Pós-Operatórias / Fatores de Tempo / Enucleação Ocular / Incidência / Estudos Retrospectivos / Seguimentos / Resultado do Tratamento / Evisceração do Olho / Implantação de Prótese / Implantes Orbitários Tipo de estudo: Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male País/Região como assunto: Asia Idioma: En Revista: Korean Journal of Ophthalmology Ano de publicação: 2015 Tipo de documento: Article