Your browser doesn't support javascript.
loading
A new method for safety monitoring of natural dietary supplements--quality profile / 中华预防医学杂志
Chinese Journal of Preventive Medicine ; (12): 489-493, 2008.
Artigo em Chinês | WPRIM | ID: wpr-352458
ABSTRACT
<p><b>OBJECTIVE</b>A new method for safety monitoring of natural dietary supplements--quality profile was proposed. It would convert passive monitoring of synthetic drug to active, and guarantee the security of natural dietary supplements. Preliminary research on quality profile was completed by high performance liquid chromatography (HPLC) and mass spectrometry (MS).</p><p><b>METHODS</b>HPLC was employed to analyze chemical constituent profiles of natural dietary supplements. The separation was completed on C18 column with acetonitrile and water (0.05% H3PO4) as mobile phase, the detection wavelength was 223 nm. Based on HPLC, stability of quality profile had been studied, and abnormal compounds in quality profile had been analyzed after addition of phenolphthalein, sibutramine, rosiglitazone, glibenclamide and gliclazide. And by MS, detector worked with ESI +, capillary voltage 3.5 kV, cone voltage 30 V, extractor voltage 4 V, RF lens voltage 0.5 V, source temperature 105 degrees C, desolvation temperature 300 degrees C, desolvation gas flow rate 260 L/h, cone gas flow rate 50 L/h, full scan mass spectra m/z 100-600. Abnormal compound in quality profile had been analyzed after addition of N-mono-desmethyl sibutramine.</p><p><b>RESULTS</b>Quality profile based on HPLC had good stability (Similarity > 0.877). Addition of phenolphthalein, sibutramine, rosiglitazone, glibenclamide and gliclazide in natural dietary supplements could be reflected by HPLC, and addition of N-mono-desmethyl sibutramine in natural dietary supplements could be reflected by MS.</p><p><b>CONCLUSION</b>Quality profile might monitor adulteration of natural dietary supplements, and prevent addition of synthetic drug after "approval".</p>
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Controle de Qualidade / Padrões de Referência / Cromatografia Líquida de Alta Pressão / Suplementos Nutricionais / Espectrometria de Massas por Ionização por Electrospray / Métodos Limite: Humanos Idioma: Chinês Revista: Chinese Journal of Preventive Medicine Ano de publicação: 2008 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Controle de Qualidade / Padrões de Referência / Cromatografia Líquida de Alta Pressão / Suplementos Nutricionais / Espectrometria de Massas por Ionização por Electrospray / Métodos Limite: Humanos Idioma: Chinês Revista: Chinese Journal of Preventive Medicine Ano de publicação: 2008 Tipo de documento: Artigo