Application of joint fixation with breast bracket and body phantom to breast cancer radiotherapy after breast-conserving operation / 医疗卫生装备
Article em Zh | WPRIM | ID: wpr-461282
Biblioteca responsável: WPRO
ABSTRACT
Objective To apply joint fixation with breast bracket and body phantom to breast cancer radiotherapy after breast-conserving operation.Methods Totally 36 patients after breast-conserving operation underwent joint fixation with breast bracket and body phantom, whose cone beam computed tomography (CBCT) images were obtained with on board imager (OBI) before radiotherapy. The errors between the CBCT images and planning CT images were acquired by matching.Results The setup errors in the directions of left-right (X), head-foot (Y) and belly-back (Z) were (2.6±0.783), (3.0± 1.027) and (1.6 ±0.872)mm respectively, and the percentages that the setup errors were more than 5 mm were 16.5%, 20.7% and 9.1% respectively.Conclusion Joint fixation with breast bracket and body phantom may decrease the setup error in radiotherapy after breast-conserving operation, especially in the belly-back direction, and thus has high clinical values.
Palavras-chave
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: Chinese Medical Equipment Journal Ano de publicação: 2015 Tipo de documento: Article