Closure of large full thickness stomach wall defect with a newly designed hemostatic clip / 中华消化内镜杂志
Article em Zh | WPRIM | ID: wpr-485240
Biblioteca responsável: WPRO
ABSTRACT
Objective To design a hemostatic clip and evaluate its efficacy and success rate of closure of stomach wall defect after full thickness resection (FTR).Methods A full thickness circular or linear resection (3 to 5 cm) was made on each model's antrum with needle knife and insulated-tip knife.The specimens were divided into 2 groups, using either an interrupted or continuous suturing method.Then the closure condition, suturing time, number of clips required and success rate of closure were compared.Results All 12 defects were successfully closed.The average closing time of interrupted and continuous suturing group were 13.33 ± 1.09 and 10.17 ±2.11 minutes, and the mean number of clips used were 4.67 ± 0.82 and 2.67 ± 0.82.The success rate was 100%.Conclusion This newly designed clip is a fast, reliable and convenient tool for stomach wall defect closure after FTR.
Palavras-chave
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: Chinese Journal of Digestive Endoscopy Ano de publicação: 2015 Tipo de documento: Article