Your browser doesn't support javascript.
loading
Locking compression plate fixation for distal radius comminuted fractures / 中华创伤骨科杂志
Article em Zh | WPRIM | ID: wpr-684604
Biblioteca responsável: WPRO
ABSTRACT
Objective To evaluate the effectiveness of locking compression plate (LCP) in treatment of comminuted fractures of distal end of radius. Methods A retrospective analysis of the clinical data was done for the 24 patients with comminuted fracture of distal end of radius who had been treated by locking compression plate fixation from August 2002 to August 2003. Results The follow up duration averaged 7.8 months. The satisfactory rate of functional outcome with LCP fixation was 91.6 percent. Conclusion Although LCP can provide the outstanding stability theoretically, it has not resulted in more exciting outcomes in treatment of comminuted fractures of distal end of radius than traditional methods.
Palavras-chave
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: Chinese Journal of Orthopaedic Trauma Ano de publicação: 2004 Tipo de documento: Article