The effect of glazing and aging on the surface properties of CAD/CAM resin blocks
The Journal of Advanced Prosthodontics
; : 50-57, 2018.
Article
em En
| WPRIM
| ID: wpr-742010
Biblioteca responsável:
WPRO
ABSTRACT
PURPOSE:
To investigate the effect of accelerated aging on surface properties of glazed CAD/CAM resin blocks using a 2D surface profilometer and a 3D non-contact optical profilometer. MATERIALS ANDMETHODS:
Three types of CAD/CAM resin restorative materials, LAVA Ultimate (3M ESPE, St Paul, MN, USA), VITA Enamic (Vita Zahnfabrik H. Rauter, Bad Säckingen, Germany), and Cerasmart (GC Corparation, Tokyo, Japan) were used for this study. CAD/CAM blocks were cut in 3-mm thickness slabs and divided into three groups; Group 1 control group (specimens polished with 600 grit SCI paper); Group 2 specimens sandblasted, silanized, and glazed with Optiglaze Color (GC); Group 3 glazed specimens subjected to 5000 thermocycles (n=15). The surface roughness (Ra and Rz) was evaluated using a profilometer and a 3D scanning instrument. Data were analyzed using two-way ANOVA and Tukey's post-hoc test (P .05). For VITA and Cerasmart, the specimens in Group 1 exhibited significantly higher Ra values than Group 2 (P .05).CONCLUSION:
Glaze material Optiglaze Color makes CAD/CAM resin surfaces smooth and glazed CAD/CAM surfaces seem resistant to deterioration under 5000 thermocycles.Palavras-chave