Treatment of Tile B pelvic fracture by external fixator combined with limited internal fixation / 中南大学学报(医学版)
Article em Zh | WPRIM | ID: wpr-814407
Biblioteca responsável: WPRO
ABSTRACT
OBJECTIVE@#To determine the effectiveness of external fixator combined with limited internal fixation for Tile B pelvic fractures.@*METHODS@#Fourteen patients with Tile B pelvic fracture were treated by external fixator combined with limited internal fixation between September 2004 and June 2009.@*RESULTS@#All the patients were followed for 6-49 (20.2 +/- 10.2) months. According to the Matta standard, the outcome of 9 patients was excellent, 4 patients were good, while the other one patient was fair.@*CONCLUSION@#External fixator combined with limited internal fixation is effective for Tile B pelvic fracture. It can not only reduce the anatomic position of the pelvis, but also strengthen the stability of the pelvis as a whole. This method is less invasive and traumatic, which promotes the recovery of patients.
Assuntos
Texto completo: 1 Índice: WPRIM Assunto principal: Ossos Pélvicos / Cirurgia Geral / Ferimentos e Lesões / Fixadores Externos / Fraturas Ósseas / Fixação de Fratura / Fixação Interna de Fraturas / Métodos Limite: Adult / Female / Humans / Male Idioma: Zh Revista: Journal of Central South University(Medical Sciences) Ano de publicação: 2010 Tipo de documento: Article
Texto completo: 1 Índice: WPRIM Assunto principal: Ossos Pélvicos / Cirurgia Geral / Ferimentos e Lesões / Fixadores Externos / Fraturas Ósseas / Fixação de Fratura / Fixação Interna de Fraturas / Métodos Limite: Adult / Female / Humans / Male Idioma: Zh Revista: Journal of Central South University(Medical Sciences) Ano de publicação: 2010 Tipo de documento: Article