Your browser doesn't support javascript.
loading
Flow injection chemiluminescence determination of biapenem for injection / 国际药学研究杂志
Article em Zh | WPRIM | ID: wpr-845742
Biblioteca responsável: WPRO
ABSTRACT
Objective To establish a new method for the rapid and sensitive determination of biapenem. Methods A simple, rapid and sensitive flow injection chemiluminescence(CL) method for the determination of biapenem was developed based on the fact that biapenem could enhance the CL of the luminol (LMN)-potassium ferricyanide reaction system under an alkaline condition. Results Under the optimal experimental conditions, we obtained a linear relationship between the CL intensity and the concentration of biapenem in the range of 0.02%0.6 mg/L with a detection limit of 7.3 x10-3 mg/L. The relative standard deviation was 1.76% for the eleven-time determination of 0.2 mg/L biapenem. Conclusion The method shows high sensitivity, low detection limit and good repeatability. It has been successfully applied to the determination of biapenem for injection and the results are satisfactory.
Palavras-chave
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: Journal of International Pharmaceutical Research Ano de publicação: 2015 Tipo de documento: Article
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: Journal of International Pharmaceutical Research Ano de publicação: 2015 Tipo de documento: Article