Your browser doesn't support javascript.
loading
Feasibility of using cortical bone trajectory screws in osteoporotic thoracolumbar fixation based on evaluation of bone CT values at bone-screw interface / 中华创伤骨科杂志
Article em Zh | WPRIM | ID: wpr-992678
Biblioteca responsável: WPRO
ABSTRACT
Objective:To evaluate the feasibility of using cortical bone trajectory (CBT) screws in the osteoporotic thoracolumbar fixation by comparing the bone CT values at the bone-screw interface between traditional trajectory (TT) screws and CBT screws in patients with different bone densities.Methods:The high-resolution CT imaging data of thoracolumbar segments following thoracic or lumbar spine fractures from April 2020 to October 2022 were collected at The Second Hospital Affiliated to Wenzhou Medical University for retrospective analysis. They were divided into 3 groups: a normal bone mass group, an osteopenia group and an osteoporosis group. From each group 30 cases were chosen (90 cases in total, 36 males and 54 females). All the data were imported into Mimics 18.0 for three-dimensional bone reconstruction in which placement of TT and CBT screws was simulated on the vertebrae from T10 to L2 (non-fractured vertebrae). Regions of interest (ROI) where each simulated screw intersected the bone were segmented to measure their CT bone values. For each vertebra in each group, the relative difference percentage in average CT value of ROI between TT and CBT screws was calculated. The CT values of ROI were compared in the same group between TT and CBT screws from T10 to L2; the CT values of ROI were compared in the same screws among the 3 groups from T10 to L2; the CT values of ROI were compared between the CBT screws in the osteopenia and osteoporosis groups and the TT screws in the normal bone mass group; the relative difference percentages in average CT value of ROI between CBT and TT screws were compared between the 3 groups from T10 to L2.Results:The average CT value of ROI for CBT screws was significantly higher than that for TT screws from T10 to L2 in every group ( P< 0.001); as for the CT values of ROI for CBT and TT screws from T10 to L2, the osteoporosis group<the osteopenia group<the normal bone mass group ( P<0.001); from T10 to L2, the CT value of ROI for CBT screws in the osteopenia group was significantly higher than that for TT screws in the normal bone mass group ( P<0.001); the CT value of ROI for CBT screws in the osteoporosis group was not significantly different from that for TT screws in the normal bone mass group ( P>0.05). At T10, T12, and L1, the relative difference percentage in average CT value of ROI between CBT and TT screws was significantly higher in the osteopenia and osteoporosis groups than that in the normal bone mass group ( P<0.05), but there was no such a difference between the osteopenia and the osteoporosis groups ( P>0.05). At T11 and L2, there was no significant difference between the 3 groups in the relative difference percentage in average CT value of ROI between CBT and TT screws ( P>0.05). Conclusions:As bone mass decreases, both CBT and TT screws lead to a significant decrease in the bone density at the bone-screw interface. In patients with osteoporosis, CBT screws can still lead to a higher bone density at the bone-screw interface than TT screws, thus providing a higher strength at the bone-screw interface.
Palavras-chave
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: Chinese Journal of Orthopaedic Trauma Ano de publicação: 2023 Tipo de documento: Article
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: Chinese Journal of Orthopaedic Trauma Ano de publicação: 2023 Tipo de documento: Article