Comparación de los métodos de antropometría y bioimpedancia eléctrica a través de la determinación de la composición corporal en estudiantado universitario / Comparison of the Methods of Anthropometry and Electrical Bioimpedance trough the Determination of Body Composition in University Students
Alomía León, Ricardo; Peña-Toncoso, Sebastián; Hernández- Mosqueira, Claudio; Espinoza Cortez, José.
Affiliation
  • Alomía León, Ricardo; Universidad Peruana Unión, Perú. PE
  • Peña-Toncoso, Sebastián; Universidad Austral de Chile; Universidad SEK, Chile. CL
  • Hernández- Mosqueira, Claudio; Universidad de La Frontera, Chile. CL
  • Espinoza Cortez, José; Universidad Adventista de Chile, Chile. CL
MHSalud ; 19(2)dic. 2022.
Article в Es | LILACS, SaludCR | ID: biblio-1405530
Ответственная библиотека: CR1.1
RESUMEN
Resumen

Objetivo:

Comparar la composición corporal por antropometría clásica e impedancia bioeléctrica en estudiantado universitario de una universidad peruana.

Método:

Estudio correlacional, transversal, conformado por 152 estudiantes (77 varones y 75 mujeres) matriculados en el ciclo 2018-II con edad promedio de 20.45 ± 3.63 años. Se calculó para el método de antropometría el índice de masa corporal, mediciones antropométricas y se utilizó la ecuación de Yuhasz (1974) para determinar el porcentaje de grasa corporal, y para el de bioimpedancia eléctrica se utilizó el analizador tetrapolar multifrecuencia de medición segmental directa Inbody 120. Para establecer la correlación se utilizó el coeficiente de Pearson y para la concordancia se utilizó el método gráfico de Bland Altman e índice de estabilidad. Los datos fueron analizados con el programa estadístico IBM SPSS Statistics, versión 27.0. Para todos los análisis se utilizó un nivel de significancia (p<0.05).

Resultados:

Existe una fuerte correlación estadísticamente significativa (p<0.01y r=0.95) entre los métodos de antropometría y bioimpedancia eléctrica para la determinación del porcentaje de grasa corporal; además, una buena concordancia según el método gráfico de Bland Altman, reforzada con el índice de estabilidad para complemento de la interpretación (IE= 95 %).

Conclusiones:

Ambos métodos son intercambiables entre sí, por lo que pueden ser usados indistintamente en este tipo de población para determinar el porcentaje de grasa corporal expresado en porcentaje.
ABSTRACT
Abstract

Objective:

The aim was to compare the body composition using classical anthropometry and bioelectric impedance in university students of a Peruvian university.

Method:

a correlational, cross-sectional study with a research sample of 152 students (77 men and 75 women) enrolled in the 2018-II period with an average age of 20.45 ± 3.63 years. The body mass index and anthropometric measurements were calculated for the anthropometric method. The Yuhasz (1974) equation was used to determine the body fat percentage. The electrical bioimpedance method implemented the tetrapolar multi-frequency direct segmental measurement analyzer Inbody 120. Pearson coefficient was used to establish the correlation, and the Bland Altman graphical method and stability index were used for concordance. The data were analyzed using the statistical software application IBM SPSS Statistics, version 27.0. A level of significance (p <0.05) was used for all analyzes.

Results:

there is a strong statistically significant correlation (p<0.01 and r = 0.95) between the anthropometric and electrical bioimpedance methods to determine body fat percentage. In addition, there is a good agreement according to the Bland Altman graphical method, reinforced by the stability index to complement the interpretation (IE = 95%).

Conclusions:

Both methods are interchangeable with each other, so they can be used indistinctly in this type of population to determine body fat percentage.
RESUMO
Resumo

Objetivo:

comparar a composição corporal por antropometria clássica e impedância bioelétrica em estudantes universitários de uma universidade peruana.

Método:

estudo correlacional, transversal, compreendendo 152 estudantes (77 homens e 75 mulheres) matriculados no ciclo 2018-II, com idade média de 20,45 ± 3,63 anos. Para o método antropométrico, o índice de massa corporal, as medidas antropométricas e a equação de Yuhasz (1974) foram calculados para determinar a porcentagem de gordura corporal; e para o método de bioimpedância elétrica foi usado o analisador tetrapolar multifrequencial com medida segmentar direta Inbody 120. O coeficiente de Pearson foi usado para estabelecer a correlação; o método gráfico Bland Altman e o índice de estabilidade foram usados para a concordância. Os dados foram analisados com o IBM SPSS Statistics, versão 27.0. Um nível de significância (p<0,05) foi usado para todas as análises.

Resultados:

há uma forte correlação estatística significativa (p<0,01 e r=0,95) entre os métodos de antropometria e bioimpedância elétrica para a determinação da porcentagem de gordura corporal; além disso, uma boa concordância de acordo com o método gráfico Bland Altman, reforçado com o índice de estabilidade para complementar a interpretação (IE= 95%).

Conclusões:

Ambos os métodos são intercambiáveis entre si, portanto, podem ser utilizados indistintamente nesse tipo de população para determinar a porcentagem de gordura corporal expressa como porcentagem.