A clinical study of NexusTM coils for endovascular occlusion of intracranial aneurysms / 中华神经医学杂志
Chinese Journal of Neuromedicine ; (12): 581-584, 2009.
Article в Zh | WPRIM | ID: wpr-1032781
Ответственная библиотека: WPRO
ABSTRACT
Objective To analyze the effect of NexusTM coils for endovascular occlusion of intracranial aneurysms. Methods In 41 patients with intracranial aneurysms, endovascular occlusion of 43 aneurysms was performed using NexusTM coils. The follow-up data of the patients for 6 to 12 months were reviewed, and the imaging data from digital subtraction angiography (DSA), CT angiography (CTA) or magnetic resonance arthrography (MRA) alter the treatment were analyzed. Results In the 41 patients, 1 died, 1 had aneurysm recurrence, 3 had cerebral infarction, 1 showed ocular paralysis, and 2 developed hydrocephalus after the surgery. Evaluation with modified Rankin Scale showed grade 0 in 8 cases, grade 1 in 19 cases, grade 2 in 7 cases, grade 3 in 3 cases, grade 4 in 1 case, grade 5 in 1 ease and grade 6 in 1 case. Conclusion Endovascular embolization with NexusTM coils is effective for treatment of intracranial aneurysms especially in cases of small aneurysms and parent artery occlusion. Caution should be taken with the coil for endovascular occlusion of the neck of anterior and middle cerebral artery aneurysms with thin parent arteries, as the fibers in the coil may cause thrombosis and potential cerebral infarction.
Key words
Полный текст: 1 База данных: WPRIM Язык: Zh Журнал: Chinese Journal of Neuromedicine Год: 2009 Тип: Article