ABSTRACT
In patients with coronary artery disease, coronary stenting with a drug-eluting stent (DES) is associated with lower rates of in-stent restenosis and re-surgery for the target lesion compared with a bare metal stent, while late stent thrombosis has emerged as a life-threatening complication in patients treated with a first-generation DES. As no treatment has been established for potentially fatal late stent thrombosis associated with a first-generation DES, we perform drug balloon angioplasty for patients with stent thrombosis and in-stent restenosis associated with DES. Here, we reported the cases with normal coronary artery flow after a 2-year follow-up.
Тема - темы
Key words
Полный текст: 1 База данных: WPRIM Основная тема: Thrombosis / Coronary Artery Disease / Stents / Follow-Up Studies / Angioplasty, Balloon / Constriction, Pathologic / Coronary Vessels / Drug-Eluting Stents Тип исследования: Etiology_studies / Observational_studies / Prognostic_studies Пределы темы: Humans Язык: Ko Журнал: Korean Journal of Medicine Год: 2015 Тип: Article
Полный текст: 1 База данных: WPRIM Основная тема: Thrombosis / Coronary Artery Disease / Stents / Follow-Up Studies / Angioplasty, Balloon / Constriction, Pathologic / Coronary Vessels / Drug-Eluting Stents Тип исследования: Etiology_studies / Observational_studies / Prognostic_studies Пределы темы: Humans Язык: Ko Журнал: Korean Journal of Medicine Год: 2015 Тип: Article