Hemoperitoneum: a complication of loop electrosurgical excision procedure
Obstetrics & Gynecology Science
; : 138-141, 2019.
Article
в En
| WPRIM
| ID: wpr-741739
Ответственная библиотека:
WPRO
ABSTRACT
Loop electrosurgical excision procedure (LEEP) is commonly performed for the management of cervical intraepithelial neoplasia. Although LEEP is considered to be a relatively simple procedure, several unexpected complications have been reported in the literature. Herein, we report a case of hemoperitoneum caused by uterine perforation following LEEP. Blood collection in pelvic cavity and two small defects of the uterus were confirmed by diagnostic laparoscopy. The defects were sutured and the patient recovered well after the operation.