Postural Intraocular Pressure Change at Trendelenberg Position Measured by Rebound Tonometer
Article 在 Ko | WPRIM | ID: wpr-90229
Responsible library: WPRO
ABSTRACT

PURPOSE:

This study was carried out to evaluate the postural intraocular pressure (IOP) change in Trendelenburg, reverse Trendelenburg, and supine positions in healthy young males.

METHODS:

We measured the IOP values of 5 healthy young male volunteers (10 eyes) using an Icare PRO rebound tonometer in sitting, Trendelenburg, reverse Trendelenburg, and supine positions.

RESULTS:

The mean IOP in the supine position (18.63 mm Hg) was significantly higher (p < 0.01) than in the sitting position (15.31 mm Hg). When maintaining the Trendelenburg position, IOP gradually increased.

CONCLUSIONS:

In our study, the Trendelenburg position significantly increased the IOP compared to that in the supine position. The effects of increased IOP should be considered in situations that require Trendelenburg positioning, such as exercise or surgery.
Subject(s)
Key words
全文: 1 索引: WPRIM 主要主题: Volunteers / Supine Position / Head-Down Tilt / Intraocular Pressure / Iron-Dextran Complex 限制: Humans / Male 语言: Ko 期刊: Journal of the Korean Ophthalmological Society 年: 2014 类型: Article