Your browser doesn't support javascript.
Use of RT-PCR thermocycling program for the quantification of DNA viruses in a single run with RNA viruses: Example of Altona RealStar® HSV or VZV PCR kits.
Andreani, Julien; Lupo, Julien; Nemoz, Benjamin; Truffot, Aurelie; Larrat, Sylvie; Morand, Patrice; Germi, Raphaële.
  • Andreani J; Laboratoire de Virologie, Centre Hospitalier Universitaire (CHU) Grenoble - Alpes, 38000 Grenoble, France; Institut de Biologie Structurale (IBS), UMR 5075 CEA-CNRS-Université Grenoble-Alpes, 38000 Grenoble, France.
  • Lupo J; Laboratoire de Virologie, Centre Hospitalier Universitaire (CHU) Grenoble - Alpes, 38000 Grenoble, France; Institut de Biologie Structurale (IBS), UMR 5075 CEA-CNRS-Université Grenoble-Alpes, 38000 Grenoble, France.
  • Nemoz B; Laboratoire de Virologie, Centre Hospitalier Universitaire (CHU) Grenoble - Alpes, 38000 Grenoble, France; Institut de Biologie Structurale (IBS), UMR 5075 CEA-CNRS-Université Grenoble-Alpes, 38000 Grenoble, France.
  • Truffot A; Laboratoire de Virologie, Centre Hospitalier Universitaire (CHU) Grenoble - Alpes, 38000 Grenoble, France; Institut de Biologie Structurale (IBS), UMR 5075 CEA-CNRS-Université Grenoble-Alpes, 38000 Grenoble, France.
  • Larrat S; Laboratoire de Virologie, Centre Hospitalier Universitaire (CHU) Grenoble - Alpes, 38000 Grenoble, France; Institut de Biologie Structurale (IBS), UMR 5075 CEA-CNRS-Université Grenoble-Alpes, 38000 Grenoble, France.
  • Morand P; Laboratoire de Virologie, Centre Hospitalier Universitaire (CHU) Grenoble - Alpes, 38000 Grenoble, France; Institut de Biologie Structurale (IBS), UMR 5075 CEA-CNRS-Université Grenoble-Alpes, 38000 Grenoble, France.
  • Germi R; Laboratoire de Virologie, Centre Hospitalier Universitaire (CHU) Grenoble - Alpes, 38000 Grenoble, France; Institut de Biologie Structurale (IBS), UMR 5075 CEA-CNRS-Université Grenoble-Alpes, 38000 Grenoble, France. Electronic address: RGermi@chu-grenoble.fr.
Infect Dis Now ; 52(8): 453-455, 2022 Nov.
Article in English | MEDLINE | ID: covidwho-2179305
ABSTRACT
Real-time PCR plays a key role in the diagnosis of viral infections. Multiple kits can detect or quantify genomes of various viruses with the same thermocycling program. Detection of RNA viruses includes an additional step of reverse transcription and challenge their detection in a single run with DNA viruses. We investigated the analytical performance of HSV-1, HSV-2 and VZV DNA quantification with Altona RealStar® PCR kits using the RT-PCR program for RNA viruses instead of the PCR program for DNA viruses. For each three viruses, Bland-Altman distribution did not show differences between both programs, and quantification curves generated with both thermocycling programs confirmed high correlation (R2 ≥ 0.9983). Detection of low viral load samples was evaluated, on 10-times repeat-test. All replicate samples were detected with both thermocycling programs and were quantified at similar viral loads (bias in log10 copies/mL +0.05 (HSV-1), -0.01 (HSV-2) and +0.25 (VZV)). This confirms the feasibility of using the RT-PCR thermocycling program to detect and quantify the genome of RNA and DNA viruses in a single run.
Subject(s)
Keywords

Full text: Available Collection: International databases Database: MEDLINE Main subject: RNA Viruses Type of study: Diagnostic study / Experimental Studies Limits: Humans Language: English Journal: Infect Dis Now Year: 2022 Document Type: Article Affiliation country: J.idnow.2022.09.005