Respiratory frequency-tunable dynamic imaging for lung function: New exam method using chest X-ray cine imaging considering various respiratory diseases.
Abe, Takehiko; Yoshida, Norifumi; Shimada, Tetsuo; Nakashima, Masanao; Nagai, Atsushi.
  • Abe T; Department of Radiology, Teikyo University, Itabashi-ku, Tokyo, Japan.
  • Yoshida N; Radwisp Pte. Ltd, The Central, Singapore, Singapore.
  • Shimada T; Department of Radiology, Teikyo University, Itabashi-ku, Tokyo, Japan.
  • Nakashima M; Radwisp Pte. Ltd, The Central, Singapore, Singapore.
  • Nagai A; Faculty of Engineering, Sanjo City University, Sanjo, Niigata, Japan.
PLoS One ; 17(11): e0276859, 2022.
Статья в английский | MEDLINE | ID: covidwho-2119142
ABSTRACT

OBJECTIVES:

A convenient way to conduct pulmonary function tests while preventing infectious diseases was proposed, together with countermeasures for severe coronavirus disease 2019 (COVID-19). The correlation between diagnosis result and diagnosis result was examined for patients with mild chronic obstructive pulmonary disease (COPD) of the most abounding as a subject of spirometry, and the possibility of using this method as an alternative to spirometry was examined.

SETTING:

This study was conducted in Kanagawa, Japan.

PARTICIPANTS:

Ten normal volunteers and 15 volunteers with mild COPD participated in this study. OUTCOME

MEASURES:

All images were taken by EXAVISTA (Hitachi, Japan) between October 2019 and February 2020. Continuous fluoroscopic images were taken in 12.5 frames per second for 10-20 s per subject. Images that do not adopt the automatic image processing of the equipment and only carry out the signal correction of each pixel were used for the analysis.

RESULTS:

The mean total dose for all volunteers was 0.2 mGy. There was no major discrepancy in the detection of lung field geometry, and no diagnostic problems were noted by the radiologist and physician.

CONCLUSIONS:

Existing X-ray cine imaging was used to extract frequency-tunable imaging. It is possible to identify abnormal regions on the images compared to spirometry, and it does not require maximum effort respiration; therefore, it is possible to perform a stable examination because the patient's physical condition and the ability of laboratory technicians on the day are less affected. This can also be used as a countermeasure in examining patients with infectious diseases. TRIAL REGISTRATION UMIN UMIN000043868.
Тема - темы

Полный текст: Имеется в наличии Коллекция: Международные базы данных база данных: MEDLINE Основная тема: Respiration Disorders / Pulmonary Disease, Chronic Obstructive / COVID-19 Тип исследования: Диагностическое исследование / Прогностическое исследование / Рандомизированные контролируемые испытания Пределы темы: Люди Язык: английский Журнал: PLoS One Тематика журнала: Наука / Медицина Год: 2022 Тип: Статья Аффилированная страна: Journal.pone.0276859

Документы, близкие по теме

MEDLINE

...
LILACS

LIS


Полный текст: Имеется в наличии Коллекция: Международные базы данных база данных: MEDLINE Основная тема: Respiration Disorders / Pulmonary Disease, Chronic Obstructive / COVID-19 Тип исследования: Диагностическое исследование / Прогностическое исследование / Рандомизированные контролируемые испытания Пределы темы: Люди Язык: английский Журнал: PLoS One Тематика журнала: Наука / Медицина Год: 2022 Тип: Статья Аффилированная страна: Journal.pone.0276859