Pedipacks in the transfusion of pediatric patients to reduce wastage of blood components: an observational study from a tertiary center.
Kanbur, Nihat Atahan; Gelen, Sema Aylan; Zengin, Emine; Sarper, Nazan.
  • Kanbur NA; Department of Pediatric Hematology, Kocaeli University Faculty of Medicine, Kocaeli, Türkiye.
  • Gelen SA; Department of Pediatric Hematology, Kocaeli University Faculty of Medicine, Kocaeli, Türkiye.
  • Zengin E; Department of Pediatric Hematology, Kocaeli University Faculty of Medicine, Kocaeli, Türkiye.
  • Sarper N; Department of Pediatric Hematology, Kocaeli University Faculty of Medicine, Kocaeli, Türkiye.
Turk J Pediatr ; 64(5): 869-875, 2022.
Статья в английский | MEDLINE | ID: covidwho-2146194
ABSTRACT

BACKGROUND:

Pedipacks prevent wastage of blood components but they are not used efficiently in pediatric clinics.

METHODS:

Red cell concentrate (RCC) and platelet concentrate volumes transfused in the last eight months in the pediatric clinics were screened. To calculate the wastage of blood components, the number of transfused pedipacks, whole unit RCC, and platelet units were screened from transfusion laboratory digital records to show the number of whole RCC units or platelets units used instead of pedipacks. The study results were shared with physicians and transfusion laboratory staff and they were trained on the subject in meetings. Two years later, the transfusion laboratory records were assessed again to evaluate pedipack usage. A google questionnaire was also submitted to the transfusion laboratories of other hospitals to assess the use of pedipacks.

RESULTS:

RCC and platelets were used in 82.9% of the transfusions, and 31.2% of RCC and 18.4 % of platelets were transfused to patients ≤12 months. During the study period, 569 pedipacks and 117 random donor or apheresis platelets separated into satellite packs would be required. But only 48 pedipacks of RCCs and 24 units of random donor platelets/apheresis platelets separated into satellite packs were used. After two years, in RCC transfusions of 0-12 month-old patients, the transfusion laboratory release of pedipacks increased to 67.9% from 13.5%. Other centers were not also using pedipacks efficiently. The main reasons were unawareness of the subject, the blood bank delivering two units of pedipacks even when only one unit was ordered and the risk of not using the second pedipack before the expiry date, and the short expiry date of irradiated pedipacks.

CONCLUSIONS:

By increasing awareness of the subject, the collaboration of the clinic and laboratory and solving bureaucratic problems, rational use of blood components can be achieved.
Тема - темы
ключевые слова

Полный текст: Имеется в наличии Коллекция: Международные базы данных база данных: MEDLINE Основная тема: Carcinoma, Renal Cell / Kidney Neoplasms Тип исследования: Экспериментальные исследования / Наблюдательное исследование / Прогностическое исследование / Рандомизированные контролируемые испытания Пределы темы: Дети / Люди / Грудные дети / Новорожденные Язык: английский Журнал: Turk J Pediatr Год: 2022 Тип: Статья

Документы, близкие по теме

MEDLINE

...
LILACS

LIS


Полный текст: Имеется в наличии Коллекция: Международные базы данных база данных: MEDLINE Основная тема: Carcinoma, Renal Cell / Kidney Neoplasms Тип исследования: Экспериментальные исследования / Наблюдательное исследование / Прогностическое исследование / Рандомизированные контролируемые испытания Пределы темы: Дети / Люди / Грудные дети / Новорожденные Язык: английский Журнал: Turk J Pediatr Год: 2022 Тип: Статья