Intra- and inter-rater reliability and agreement of stimulus electrodiagnostic tests in post-COVID-19 patients.
da Silva Almeida, Isabella; Gomes de Jesus Ferreira, Leandro; de Almeida Ventura, Álvaro; Mansur, Henrique; Babault, Nicolas; de Cássia Marqueti, Rita; Durigan, João Luiz Quagliotti.
  • da Silva Almeida I; University of Brasilia, Faculty of Ceilândia, Rehabilitation Sciences Program, Laboratory of Muscle and Tendon Plasticity, Brazil.
  • Gomes de Jesus Ferreira L; University of Brasilia, Faculty of Ceilândia, Rehabilitation Sciences Program, Laboratory of Muscle and Tendon Plasticity, Brazil.
  • de Almeida Ventura Á; University of Brasilia, Faculty of Ceilândia, Rehabilitation Sciences Program, Laboratory of Muscle and Tendon Plasticity, Brazil.
  • Mansur H; Department of Orthopaedics, Hospital Santa Helena-Rede D'or, Brasília, Brazil.
  • Babault N; Centre d'Expertise de la Performance, INSERM U1093, UFR des Sciences du Sport, University of Burgundy Franche-Comté, France.
  • de Cássia Marqueti R; University of Brasilia, Faculty of Ceilândia, Rehabilitation Sciences Program, Laboratory of Molecular Analisys, Brazil.
  • Durigan JLQ; University of Brasilia, Faculty of Ceilândia, Rehabilitation Sciences Program, Laboratory of Muscle and Tendon Plasticity, Brazil.
Physiol Meas ; 44(5)2023 05 25.
Статья в английский | MEDLINE | ID: covidwho-2313895
ABSTRACT
Background. COVID-19 patients may present sequelae, such as neuromuscular electrophysiological disorders (NED), that can be assessed using the stimulus electrodiagnostic test (SET). However, little is known about the reliability and agreement of the SET in post-COVID-19 patients.Objective. We aimed to verify the intra-inter-rater reliability and agreement of SET measurements in the rectus femoris, vastus medialis, vastus lateralis, tibialis anterior, and gastrocnemius lateralis (GL) in post-COVID-19 participants.Methods. We designed an observational prospective study to evaluate 20 (10 males and 10 females) post-COVID-19 patients, age 44.95 ± 11.07 years, weight 87.99 ± 19.08 kg, height 1.69 ± 0.09 m. Two independent raters took two evaluations using the SET on selected muscles. The intra-class correlation coefficient (ICC) and 95% limits of the agreement defined the quality and magnitude of the measures.Results. For intra-rater reliability, all measurements presented correlations classified as high or very high (ICC 0.71-1.0). For inter-rater reliability, the rheobase, chronaxie, accommodation, and accommodation index presented high or very high correlations, except for the accommodation index of the GL (ICC = 0.65), which was moderate.Conclusion. The reliability of the SET obtained by independent raters was very high, except for the GL accommodation, which presented moderate ICC. Therefore, the SET is a reliable tool for evaluating NED in post-COVID-19 patients.
Тема - темы
ключевые слова

Полный текст: Имеется в наличии Коллекция: Международные базы данных база данных: MEDLINE Основная тема: COVID-19 Тип исследования: Когортное исследование / Диагностическое исследование / Экспериментальные исследования / Наблюдательное исследование / Прогностическое исследование Темы: Длинный Ковид Пределы темы: Взрослые / Женщины / Люди / Мужчины / Middle aged Язык: английский Тематика журнала: Биофизика / Биомедицинская инженерия / Физиология Год: 2023 Тип: Статья Аффилированная страна: 1361-6579

Документы, близкие по теме

MEDLINE

...
LILACS

LIS


Полный текст: Имеется в наличии Коллекция: Международные базы данных база данных: MEDLINE Основная тема: COVID-19 Тип исследования: Когортное исследование / Диагностическое исследование / Экспериментальные исследования / Наблюдательное исследование / Прогностическое исследование Темы: Длинный Ковид Пределы темы: Взрослые / Женщины / Люди / Мужчины / Middle aged Язык: английский Тематика журнала: Биофизика / Биомедицинская инженерия / Физиология Год: 2023 Тип: Статья Аффилированная страна: 1361-6579