ABSTRACT
From all US Army enlistees leaving Vietnam in September 1971, a random sample of 943 men was selected. Of these, 470 represented a "general" sample of all enlistees returning at that time, and 495 represented a "drug positive" sample whose urine samples had been positive for opiates at the time of departure. We attempted to locate and personally interview all of the men in the samples. Results indicate that before arrival, hard drug use was largely casual, and less than 1% had ever been addicted to narcotics. In Vietnam, almost half of the general sample tried narcotics and 20% reported opiate addiction. After return, usage and addiction essentially decreased to pre-Vietnam levels. We discuss the use of nonnarcotic drugs, predictors and correlates of drug use in the samples, and the relationship of drugs to post-Vietnam social adjustment.
Subject(s)
Military Psychiatry , Substance-Related Disorders/etiology , Age Factors , Alcohol Drinking , Amphetamine/urine , Barbiturates/urine , Cannabis , Heroin , Humans , Injections, Intravenous , Male , Narcotics/urine , Opium , Socioeconomic Factors , Substance Withdrawal Syndrome/epidemiology , Time Factors , United States , Veterans , VietnamABSTRACT
To examine the urinary excretion of opiates and their metabolites following inhalation exposure of rats to opium, analytical procedures for the simultaneous determination of the compounds in opium, the vapor derived by the volatilization of opium and the urine of rats exposed to the opium vapor were developed using liquid chromatography-atmospheric pressure chemical ionization mass spectrometry (LC-APCI-MS). Seven compounds were determined in the opium, namely morphine, codeine, thebaine, noscapine, papaverine, meconic acid and meconin. All seven were extracted with 2.5% acetic acid solution and subjected to LC-APCI-MS analysis. The separation was performed on an ODS column in acetonitrile-50 mM ammonium formate buffer (pH 3.0) using a linear gradient program and quantitative analysis was carried out in the selected ion monitoring mode ([M+H](+)). For the analysis of the volatilization of opium, the opium (1 g) was added to a glass pipe, which was then heated at 300 degrees C for 20 min. Negative pressure (air flow-rate; 300 ml/min) was used to draw the vapor through a series of glass wool and methanol traps. The total amount of each compound in the vapor was estimated by measurement of the compounds trapped in the glass wool and methanol. Wister rats (n=3) were exposed to the vapor derived from the volatilization system and the urinary amounts (0-72 h) of the six opiates and metabolites including morphine-3-grucronide (M3G) and morphine-6-grucronide (M6G) were measured after solid-phase extraction. The calibration curves for those compounds in the rat urine were linear over the concentration range 10-500 ng/ml. The recoveries for each analyte from the rat urine sample spiked with standard solution were generally greater than 80%, and the relative standard deviation for the analytical procedure was less than 8% with the exception of meconin. After inhalation exposure of rats to opium, M3G (5.45-14.38 micro g), morphine (2.27-4.65 micro g), meconin (0.54-1.85 micro g), codeine (0.54-1.85 micro g), noscapine (0.34-0.40 micro g) and papaverine (0.01-0.04 micro g) were detected in the urine over 72 h. However, only trace levels of thebaine were observed despite it being one of the major alkaloids found in the opium. On the other hand, a relatively large amount of meconin was detected in the vapor and the urine as compared with the opium. It is suggested that the presence of meconin in biological fluids could be indicative of opium ingestion by inhalation.
Subject(s)
Chromatography, Liquid/methods , Mass Spectrometry/methods , Narcotics/urine , Opium/administration & dosage , Administration, Inhalation , Animals , Atmospheric Pressure , Calibration , Narcotics/isolation & purification , Rats , Reference Standards , Reproducibility of Results , Sensitivity and SpecificityABSTRACT
A fast liquid chromatographic method with tandem diode array-fluorescence detection for the simultaneous determination of in total 17 opium alkaloids and opioids is presented. Blank blood and urine samples (1 ml) were spiked with different concentrations of a standard mixture, as well as with the internal standard, butorphanol (2000 ng/ml). After solid-phase extraction, based on weak cation exchange (Bond Elut CBA SPE columns), the extracts were examined by HPLC-DAD-FL. By using a "high-speed" phenyl column (53 x 7.0 mm I.D., particle size 3 microm) eluted with a gradient system (A: water-methanol (90:10, v/v), B: methanol, both containing 25 mM triethylammoniumformate (pH(A) = 4.5)) all compounds could be baseline separated within 12 min. The method was validated and its applicability was demonstrated by the analysis of real-time forensic cases.
Subject(s)
Chromatography, High Pressure Liquid/methods , Narcotics/analysis , Opium/analysis , Spectrometry, Fluorescence/methods , Spectrophotometry, Ultraviolet/methods , Chromatography, Ion Exchange , Narcotics/blood , Narcotics/urine , Opium/blood , Opium/urine , Reference Standards , Reproducibility of Results , Sensitivity and SpecificityABSTRACT
BACKGROUND: Narcotic abuse has steadily become more prevalent in Israel and may result in an increasing number of children exposed prenatally to narcotics, with a consequent increase in the number of infants born with neonatal abstinence syndrome. OBJECTIVE: To report our experience with infants born to narcotic-addicted women between the years 1995 and 1998 at the Soroka University Medical Center. METHODS: The medical records of 24 newborns and their drug-addicted mothers admitted to our Medical Center for parturition were analyzed retrospectively. A diagnosis of NAS was established on the basis of the clinical presentation and anamnesis. The Finnegan Neonatal Abstinence Scoring System was used to assess drug withdrawal. Urine toxicological analysis for narcotics was done only for the year 1998. RESULTS: Of the 24 newborn infants exposed prenatally to narcotics 23 (96%) developed NAS, and 78% (18 of the 23) had a Finnegan score of 8 or more. These 18 infants were treated pharmacologically (tincture of opium and/or phenobarbital) until the score was reduced to less than 8, after which they received supportive treatment. In one child who became lethargic after the first dose of tincture of opium, the medication was stopped and supportive treatment alone was given. Four of the five neonates with scores of 7 and less were given supportive treatment. One of five infants who had a low Finnegan score at birth nevertheless received pharmacological therapy to prevent further deterioration of his physical state since he was born with severe dyspnea. Ten of the 24 children (42%) were followed for lengths of time ranging from 6 to 22 months after discharge, all of whom showed normal development. CONCLUSIONS: About three-quarters of newborns exhibiting withdrawal syndrome required pharmacological therapy. Previous information on maternal drug abuse is a crucial criterion for early detection and treatment.
Subject(s)
Child Development , Maternal-Fetal Exchange , Narcotics/adverse effects , Substance Withdrawal Syndrome/therapy , Adult , Anticonvulsants/therapeutic use , Female , Follow-Up Studies , Humans , Infant, Newborn , Israel , Middle Aged , Narcotics/urine , Opium/therapeutic use , Phenobarbital/therapeutic use , Pregnancy , Retrospective Studies , Substance Withdrawal Syndrome/classification , Substance Withdrawal Syndrome/physiopathologyABSTRACT
The authors selected 38 thin-layer-chromatography (TLC) systems described in the available literature published over the last 10 years and evaluated those systems with respect to their suitability for detection and identification of opiates in urine, opium and heroin, as well as adulterants in heroin. A total of 14 substances: 8 opiates (morphine, 6-monoacetylmorphine, diacetylmorphine, codeine, acetylcodeine, noscapine, papaverine and thebaine) and 6 adulterants (ephedrine, quinine, methadone, caffeine, cocaine and strychnine) were used as test samples for this research. Using laboratory-coated plates and pre-coated plates, 15 and 13 TLC systems, respectively, were found to be able to detect and identify morphine and codeine in urine without interference from the remaining 12 substances. For the detection of opiates in opium samples as well as opiates and adulterants in illicit heroin samples the TLC system: chloroform-n-hexane-triethylamine (9:9:4) which was developed by the National Drug Research Centre, Penang, Malaysia, was found to be most suitable on both laboratory-coated and pre-coated plates. In addition, the following two systems, one on laboratory-coated plates--hexane-chloroform-diethylamine (50:30:7)--and the other on pre-coated plates--benzene-dioxane-ethanol-ammonia (50:40:5:5; T-7)--were also found to be among most suitable TLC systems for the analysis of opiates in opium samples. The article also presents the relative cost of each of the 38 evaluated TLC systems.