Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 399
Filter
1.
Magn Reson Med ; 92(5): 2074-2080, 2024 Nov.
Article in English | MEDLINE | ID: mdl-38852176

ABSTRACT

PURPOSE: Development of a color scheme representation to facilitate the interpretation of tri-exponential DWI data from abdominal organs, where multi-exponential behavior is more pronounced. METHODS: Multi-exponential analysis of DWI data provides information about the microstructure of the tissue under study. The tri-exponential signal analysis generates numerous parameter images that are difficult to analyze individually. Summarized color images can simplify at-a-glance analysis. A color scheme was developed in which the slow, intermediate, and fast diffusion components were each assigned to a different red, green, and blue color channel. To improve the appearance of the image, histogram equalization, gamma correction, and white balance were used, and the processing parameters were adjusted. Examples of the resulting color maps of the diffusion fractions of healthy and pathological kidney and prostate are shown. RESULTS: The color maps obtained by the presented method show the merged information of the slow, intermediate, and fast diffusion components in a single view. A differentiation of the different fractions becomes clearly visible. Fast diffusion regimes, such as in the renal hilus, can be clearly distinguished from slow fractions, such as in dense tumor tissue. CONCLUSION: Combining the diffusion information from tri-exponential DWI analysis into a single color image allows for simplified interpretation of the diffusion fractions. In the future, such color images may provide additional information about the microstructural nature of the tissue under study.


Subject(s)
Algorithms , Diffusion Magnetic Resonance Imaging , Humans , Diffusion Magnetic Resonance Imaging/methods , Male , Color , Image Interpretation, Computer-Assisted/methods , Kidney/diagnostic imaging , Image Enhancement/methods , Reproducibility of Results , Abdomen/diagnostic imaging , Sensitivity and Specificity , Colorimetry , Prostate/diagnostic imaging
2.
Eur J Nucl Med Mol Imaging ; 51(5): 1451-1461, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38133687

ABSTRACT

PURPOSE: To evaluate if a machine learning prediction model based on clinical and easily assessable imaging features derived from baseline breast [18F]FDG-PET/MRI staging can predict pathologic complete response (pCR) in patients with newly diagnosed breast cancer prior to neoadjuvant system therapy (NAST). METHODS: Altogether 143 women with newly diagnosed breast cancer (54 ± 12 years) were retrospectively enrolled. All women underwent a breast [18F]FDG-PET/MRI, a histopathological workup of their breast cancer lesions and evaluation of clinical data. Fifty-six features derived from positron emission tomography (PET), magnetic resonance imaging (MRI), sociodemographic / anthropometric, histopathologic as well as clinical data were generated and used as input for an extreme Gradient Boosting model (XGBoost) to predict pCR. The model was evaluated in a five-fold nested-cross-validation incorporating independent hyper-parameter tuning within the inner loops to reduce the risk of overoptimistic estimations. Diagnostic model-performance was assessed by determining the area under the curve of the receiver operating characteristics curve (ROC-AUC), sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy. Furthermore, feature importances of the XGBoost model were evaluated to assess which features contributed most to distinguish between pCR and non-pCR. RESULTS: Nested-cross-validation yielded a mean ROC-AUC of 80.4 ± 6.0% for prediction of pCR. Mean sensitivity, specificity, PPV, and NPV of 54.5 ± 21.3%, 83.6 ± 4.2%, 63.6 ± 8.5%, and 77.6 ± 8.1% could be achieved. Histopathological data were the most important features for classification of the XGBoost model followed by PET, MRI, and sociodemographic/anthropometric features. CONCLUSION: The evaluated multi-source XGBoost model shows promising results for reliably predicting pathological complete response in breast cancer patients prior to NAST. However, yielded performance is yet insufficient to be implemented in the clinical decision-making process.


Subject(s)
Breast Neoplasms , Humans , Female , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/therapy , Fluorodeoxyglucose F18 , Retrospective Studies , Magnetic Resonance Imaging/methods , Positron-Emission Tomography , Machine Learning
3.
J Magn Reson Imaging ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38963154

ABSTRACT

BACKGROUND: Lower back pain affects 75%-85% of people at some point in their lives. The detection of biochemical changes with sodium (23Na) MRI has potential to enable an earlier and more accurate diagnosis. PURPOSE: To measure 23Na relaxation times and apparent tissue sodium concentration (aTSC) in ex-vivo intervertebral discs (IVDs), and to investigate the relationship between aTSC and histological Thompson grade. STUDY TYPE: Ex-vivo. SPECIMEN: Thirty IVDs from the lumbar spines of 11 human body donors (4 female, 7 male, mean age 86 ± 8 years). FIELD STRENGTH/SEQUENCE: 3 T; density-adapted 3D radial sequence (DA-3D-RAD). ASSESSMENT: IVD 23Na longitudinal (T1), short and long transverse (T2s* and T2l*) relaxation times and the proportion of the short transverse relaxation (ps) were calculated for one IVD per spine sample (11 IVDs). Furthermore, aTSCs were calculated for all IVDs. The degradation of the IVDs was assessed via histological Thompson grading. STATISTICAL TESTS: A Kendall Tau correlation (τ) test was performed between the aTSCs and the Thompson grades. The significance level was set to P < 0.05. RESULTS: Mean 23Na relaxation parameters of a subset of 11 IVDs were T1 = 9.8 ± 1.3 msec, T2s* = 0.7 ± 0.1 msec, T2l* = 7.3 ± 1.1 msec, and ps = 32.7 ± 4.0%. A total of 30 IVDs were examined, of which 3 had Thompson grade 1, 4 had grade 2, 5 had grade 3, 5 had grade 4, and 13 had grade 5. The aTSC decreased with increasing degradation, being 274.6 ± 18.9 mM for Thompson grade 1 and 190.5 ± 29.5 mM for Thompson grade 5. The correlation between whole IVD aTSC and Thompson grade was significant and strongly negative (τ = -0.56). DATA CONCLUSION: This study showed a significant correlation between aTSC and degenerative IVD changes. Consequently, aTSC has potential to be useful as an indicator of degenerative spinal changes. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 1.

4.
World J Urol ; 42(1): 530, 2024 Sep 20.
Article in English | MEDLINE | ID: mdl-39302458

ABSTRACT

BACKGROUND: This study aimed to validate a previously published risk model (RM) which combines clinical and multiparametric MRI (mpMRI) parameters to predict extraprostatic extension (EPE) of prostate cancer (PC) prior to radical prostatectomy (RP). MATERIALS AND METHODS: A previously published RM combining clinical with mpMRI parameters including European Society of Urogenital Radiology (ESUR) classification for EPE was retrospectively evaluated in a cohort of two urological university hospitals in Germany. Consecutive patients (n = 205, January 2015 -June 2021) with available preoperative MRI images, clinical information including PSA, prostate volume, ESUR classification for EPE, histopathological results of MRI-fusion biopsy and RP specimen were included. Validation was performed by receiver operating characteristic analysis and calibration plots. The RM's performance was compared to ESUR criteria. RESULTS: Histopathological T3 stage was detected in 43% of the patients (n = 89); 45% at Essen and 42% at Düsseldorf. Discrimination performance between pT2 and pT3 of the RM in the entire cohort was AUC = 0.86 (AUC = 0.88 at site 1 and AUC = 0.85 at site 2). Calibration was good over the entire probability range. The discrimination performance of ESUR classification alone was comparable (AUC = 0.87). CONCLUSIONS: The RM showed good discriminative performance to predict EPE for decision-making for RP as a patient-tailored risk stratification. However, when experienced MRI reading is available, standardized MRI reading with ESUR scoring is comparable regarding information outcome. A main limitation is the potentially limited transferability to other populations because of the high prevalence of EPE in our subgroups.


Subject(s)
Multiparametric Magnetic Resonance Imaging , Neoplasm Invasiveness , Prostatectomy , Prostatic Neoplasms , Humans , Male , Prostatic Neoplasms/pathology , Prostatic Neoplasms/surgery , Prostatic Neoplasms/diagnostic imaging , Retrospective Studies , Risk Assessment , Middle Aged , Aged , Prostatectomy/methods , Predictive Value of Tests , Preoperative Care/methods
5.
Int J Cancer ; 152(5): 854-864, 2023 03 01.
Article in English | MEDLINE | ID: mdl-36121664

ABSTRACT

PROBASE is a population-based, randomized trial of 46 495 German men recruited at age 45 to compare effects of risk-adapted prostate cancer (PCa) screening starting either immediately at age 45, or at a deferred age of 50 years. Based on prostate-specific antigen (PSA) levels, men are classified into risk groups with different screening intervals: low-risk (<1.5 ng/ml, 5-yearly screening), intermediate-risk (1.5-2.99 ng/ml, 2 yearly), and high risk (>3 ng/ml, recommendation for immediate biopsy). Over the first 6 years of study participation, attendance rates to scheduled screening visits varied from 70.5% to 79.4%, depending on the study arm and risk group allocation, in addition 11.2% to 25.4% of men reported self-initiated PSA tests outside the PROBASE protocol. 38.5% of participants had a history of digital rectal examination or PSA testing prior to recruitment to PROBASE, frequently associated with family history of PCa. These men showed higher rates (33% to 57%, depending on subgroups) of self-initiated PSA testing in-between PROBASE screening rounds. In the high-risk groups (both arms), the biopsy acceptance rate was 64% overall, but was higher among men with screening PSA ≥4 ng/ml (>71%) and with PIRADS ≥3 findings upon multiparameter magnetic resonance imaging (mpMRI) (>72%), compared with men with PSA ≥3 to 4 ng/ml (57%) or PIRADS score ≤ 2 (59%). Overall, PROBASE shows good acceptance of a risk-adapted PCa screening strategy in Germany. Implementation of such a strategy should be accompanied by a well-structured communication, to explain not only the benefits but also the harms of PSA screening.


Subject(s)
Prostate-Specific Antigen , Prostatic Neoplasms , Humans , Male , Middle Aged , Biopsy , Early Detection of Cancer/methods , Mass Screening/methods , Prostatic Neoplasms/diagnosis , Prostatic Neoplasms/pathology , Risk Factors
6.
Eur Radiol ; 33(9): 6179-6188, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37045980

ABSTRACT

OBJECTIVES: To investigate the diagnostic feasibility of a shortened breast PET/MRI protocol in breast cancer patients. METHODS: Altogether 90 women with newly diagnosed T1tumor-staged (T1ts) and T2tumor-staged (T2ts) breast cancer were included in this retrospective study. All underwent a dedicated comprehensive breast [18F]FDG-PET/MRI. List-mode PET data were retrospectively reconstructed with 20, 15, 10, and 5 min for each patient to simulate the effect of reduced PET acquisition times. The SUVmax/mean of all malign breast lesions was measured. Furthermore, breast PET data reconstructions were analyzed regarding image quality, lesion detectability, signal-to-noise ratio (SNR), and image noise (IN). The simultaneously acquired comprehensive MRI protocol was then shortened by retrospectively removing sequences from the protocol. Differences in malignant breast lesion detectability between the original and the fast breast MRI protocol were evaluated lesion-based. The 20-min PET reconstructions and the original MRI protocol served as reference. RESULTS: In all PET reconstructions, 127 congruent breast lesions could be detected. Group comparison and T1ts vs. T2ts subgroup comparison revealed no significant difference of subjective image quality between 20, 15, 10, and 5 min acquisition times. SNR of qualitative image evaluation revealed no significant difference between different PET acquisition times. A slight but significant increase of IN with decreasing PET acquisition times could be detected. Lesion SUVmax group comparison between all PET acquisition times revealed no significant differences. Lesion-based evaluation revealed no significant difference in breast lesion detectability between original and fast breast MRI protocols. CONCLUSIONS: Breast [18F]FDG-PET/MRI protocols can be shortened from 20 to below 10 min without losing essential diagnostic information. KEY POINTS: • A highly accurate breast cancer evaluation is possible by the shortened breast [18F]FDG-PET/MRI examination protocol. • Significant time saving at breast [18F]FDG-PET/MRI protocol could increase patient satisfaction and patient throughput for breast cancer patients at PET/MRI.


Subject(s)
Breast Neoplasms , Humans , Female , Breast Neoplasms/diagnostic imaging , Fluorodeoxyglucose F18 , Retrospective Studies , Radiopharmaceuticals/pharmacology , Positron-Emission Tomography/methods , Magnetic Resonance Imaging/methods
7.
Eur Radiol ; 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-38038758

ABSTRACT

OBJECTIVES: To investigate the specific strengths of MRI and PET components in 68Ga-PSMA-11 PET/MRI for staging of patients with biochemically recurrent prostate cancer (PCa). METHODS: Patients with biochemical recurrence of PCa and contrast-enhanced whole-body 68Ga-PSMA-11 PET/MRI including a dedicated pelvic multiparametric MRI were included in this retrospective study. Imaging datasets of MRI and PET were evaluated separately regarding local PCa recurrence (Tr), pelvic lymph node metastases (N1), distant lymph node metastases (M1a), bone metastases (M1b), and soft tissue metastases (M1c) according to PROMISE version 1. Data evaluation was performed patient- and region-/lesion-based. Cox regression revealed a PSA of 1.69 ng/mL as a cut-off for subgroup analysis. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were evaluated for each image component. Differences in staging accuracy were assessed using the Wilcoxon and McNemar test. RESULTS: Altogether 102 patients (mean aged 68 ± 8 years, median PSA 1.33 ng/mL) were included. PCa was found in 70/102 (68%) patients. Accuracy of MRI in the detection of Tr, N1, M + , M1a, and M1b was 100%, 79%, 90%, 97%, and 95% for PSA < 1.69 ng/mL and 100%, 87%, 87%, 91%, and 96% for PSA > 1.69 ng/mL. Accuracy of 68Ga-PSMA-11 PET was 93%, 97%, 93%, 98%, and 100% for PSA < 1.69 ng/mL and 87%, 91%, 96%, 100%, and 96% for PSA > 1.69 ng/mL. CONCLUSIONS: Combined assessment of 68Ga-PSMA-11 PET/MRI improves tumor localization in men with biochemical recurrence. The MRI detected local recurrence of PCa more often whereas 68 Ga-PSMA-11 PET detected lymph node metastases more often, especially for PSA < 1.69 ng/mL. CLINICAL RELEVANCE STATEMENT: This study gives a scientific baseline to improve the understanding and reading of 68Ga-PSMA-11 PET/MRI imaging in patients with biochemically recurrent PCa by showing the specific strength of each imaging component. KEY POINTS: • Combining the individual modality strengths of 68Ga-PSMA-11 PET/MRI improves tumor localization in men with biochemical recurrence of prostate cancer. • MRI component of 68 Ga-PSMA-11 PET/MRI shows its strength in detecting local recurrence of prostate cancer, especially at PSA < 1.69 ng/mL. • 68 Ga-PSMA-11 PET component shows its strength in detecting local and distant lymph node metastases, especially at PSA < 1.69 ng/mL.

8.
Eur Radiol ; 33(11): 8366-8375, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37338559

ABSTRACT

OBJECTIVES: Evaluate the influence of an MRI contrast agent application on primary and follow-up staging in pediatric patients with newly diagnosed lymphoma using [18F]FDG PET/MRI to avoid adverse effects and save time and costs during examination. METHODS: A total of 105 [18F]FDG PET/MRI datasets were included for data evaluation. Two different reading protocols were analyzed by two experienced readers in consensus, including for PET/MRI-1 reading protocol unenhanced T2w and/or T1w imaging, diffusion-weighted imaging (DWI), and [18F]FDG PET imaging and for PET/MRI-2 reading protocol an additional T1w post contrast imaging. Patient-based and region-based evaluation according to the revised International Pediatric Non-Hodgkin's Lymphoma (NHL) Staging System (IPNHLSS) was performed, and a modified standard of reference was applied comprising histopathology and previous and follow-up cross-sectional imaging. Differences in staging accuracy were assessed using the Wilcoxon and McNemar tests. RESULTS: In patient-based analysis, PET/MRI-1 and PET/MRI-2 both determined a correct IPNHLSS tumor stage in 90/105 (86%) exams. Region-based analysis correctly identified 119/127 (94%) lymphoma-affected regions. Sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy for PET/MRI-1 and PET/MRI-2 were 94%, 97%, 90%, 99%, 97%, respectively. There were no significant differences between PET/MRI-1 and PET/MRI-2. CONCLUSIONS: The use of MRI contrast agents in [18F]FDG PET/MRI examinations has no beneficial effect in primary and follow-up staging of pediatric lymphoma patients. Therefore, switching to a contrast agent-free [18F]FDG PET/MRI protocol should be considered in all pediatric lymphoma patients. CLINICAL RELEVANCE STATEMENT: This study gives a scientific baseline switching to a contrast agent-free [18F]FDG PET/MRI staging in pediatric lymphoma patients. This could avoid side effects of contrast agents and saves time and costs by a faster staging protocol for pediatric patients. KEY POINTS: • No additional diagnostic benefit of MRI contrast agents at [18F]FDG PET/MRI examinations of pediatric lymphoma primary and follow-up staging • Highly accurate primary and follow-up staging of pediatric lymphoma patients at MRI contrast-free [18F]FDG PET/MRI.


Subject(s)
Fluorodeoxyglucose F18 , Lymphoma , Humans , Child , Fluorodeoxyglucose F18/pharmacology , Contrast Media/pharmacology , Neoplasm Staging , Magnetic Resonance Imaging/methods , Lymphoma/diagnostic imaging , Lymphoma/pathology , Positron-Emission Tomography/methods , Radiopharmaceuticals/pharmacology , Sensitivity and Specificity
9.
J Vasc Interv Radiol ; 34(12): 2162-2172.e2, 2023 12.
Article in English | MEDLINE | ID: mdl-37634850

ABSTRACT

PURPOSE: To compare the mechanistic effects and hypertrophy outcomes using 2 different portal vein embolization (PVE) regimens in normal and cirrhotic livers in a large animal model. METHODS AND MATERIALS: The Institutional Animal Care and Use Committee approved all experiments conducted in this study. Fourteen female Yorkshire pigs were separated into a cirrhotic group (CG, n = 7) and non-cirrhotic group (NCG, n = 7) and further subgrouped into those using microspheres and coils (MC, n = 3) or n-butyl cyanoacrylate (nBCA, n = 3) and their corresponding controls (each n = 1). A 3:1 ethiodized oil and ethanol mixture was administered intra-arterially in the CG to induce cirrhosis 4 weeks before PVE. Animals underwent baseline computed tomography (CT), PVE including pre-PVE and post-PVE pressure measurements, and CT imaging at 2 and 4 weeks after PVE. Immunofluorescence stainings for CD3, CD16, Ki-67, and caspase 3 were performed to assess immune cell infiltration, hepatocyte proliferation, and apoptosis. Statistical significance was tested using the Student's t test. RESULTS: Four weeks after PVE, the percentage of future liver remnant (FLR%) increased by 18.8% (standard deviation [SD], 3.6%) vs 10.9% (SD, 0.95%; P < .01) in the NCG vs CG. The baseline percentage of standardized future liver remnant (sFLR%) for the controls were 41.6% for CG vs 43.6% for NCG. Based on the embolic agents used, the sFLR% two weeks after PVE was 58.4% (SD, 3.7%) and 52.2% (SD, 0.9%) (P < .01) for MC and 46.0% (SD, 2.2%) and 47.2% (SD, 0.4%) for nBCA in the NCG and CG, respectively. Meanwhile, the sFLR% 4 weeks after PVE was 60.5% (SD, 3.9%) and 54.9% (SD, 0.8%) (P < .01) and 60.4% (SD, 3.5%) and 54.2% (SD, 0.95%) (P < .01), respectively. Ki-67 signal intensity increased in the embolized lobe in both CG and NCG (P < .01). CONCLUSIONS: This preclinical study demonstrated that MC could be the preferred embolic of choice compared to nBCA when a substantial and rapid FLR increase is needed for resection, in both cirrhotic and non-cirrhotic livers.


Subject(s)
Embolism , Embolization, Therapeutic , Liver Neoplasms , Animals , Female , Swine , Portal Vein/diagnostic imaging , Portal Vein/pathology , Ki-67 Antigen , Liver/pathology , Hepatectomy/methods , Embolization, Therapeutic/methods , Liver Neoplasms/therapy , Hypertrophy/pathology , Hypertrophy/surgery , Embolism/surgery , Liver Cirrhosis/complications , Liver Cirrhosis/diagnostic imaging , Models, Animal , Treatment Outcome
10.
Int J Mol Sci ; 24(3)2023 Jan 27.
Article in English | MEDLINE | ID: mdl-36768814

ABSTRACT

(1) Background: Sympathetic overactivity is a major contributor to resistant hypertension (RH). According to animal studies, sympathetic overactivity increases immune responses, thereby aggravating hypertension and cardiovascular outcomes. Renal denervation (RDN) reduces sympathetic nerve activity in RH. Here, we investigate the effect of RDN on T-cell signatures in RH. (2) Methods: Systemic inflammation and T-cell subsets were analyzed in 17 healthy individuals and 30 patients with RH at baseline and 6 months after RDN. (3) Results: The patients with RH demonstrated higher levels of pro-inflammatory cytokines and higher frequencies of CD4+ effector memory (TEM), CD4+ effector memory residential (TEMRA) and CD8+ central memory (TCM) cells than the controls. After RDN, systolic automated office blood pressure (BP) decreased by -17.6 ± 18.9 mmHg. Greater BP reductions were associated with higher CD4+ TEM (r -0.421, p = 0.02) and CD8+ TCM (r -0.424, p = 0.02) frequencies at baseline. The RDN responders, that is, the patients with ≥10mmHg systolic BP reduction, showed reduced pro-inflammatory cytokine levels, whereas the non-responders had unchanged inflammatory activity and higher CD8+ TEMRA frequencies with increased cellular cytokine production. (4) Conclusions: The pro-inflammatory state of patients with RH is characterized by altered T-cell signatures, especially in non-responders. A detailed analysis of T cells might be useful in selecting patients for RDN.


Subject(s)
Hypertension , Hypotension , Humans , Sympathectomy , Treatment Outcome , T-Lymphocytes , Kidney , Blood Pressure/physiology , Cytokines
11.
J Radiol Prot ; 43(3)2023 09 11.
Article in English | MEDLINE | ID: mdl-37619552

ABSTRACT

Although iso-centric patient positioning is enormously important in computed tomography (CT), it is complicated in thoracoabdominal imaging by the varying dimensions of the body. Patient positioning can affect the appearance of the patient on the localiser. Positioned too close to the x-ray tube, a patient appears considerably more voluminous. The goal of this study is to assess the difference in radiation exposure of combined chest and abdomen CT scans between scans with prior 0°- and 180°-localisers in conjunction with patient positioning. In this IRB-approved retrospective study, patients who had two routine thoracoabdominal CT scans on the same CT scanner, one with a prior 0°- and one with a prior 180°-localiser, were included. To evaluate the radiation exposure of the thoracoabdominal CT examination regarding the tube position during the localiser, volumetric computed tomography dose index (CTDIvol), size-specific dose estimate (SSDE), patient diameter and positioning within the iso-centre for three positions (heart, abdomen, femur level) were compared with regard to the tube position during the prior localiser. CT examinations of 114 patients were included. Despite similar patient weight and diameter between the two examinations, SSDE and CTDIvolwas significantly larger (up to 73%) with 180°-localisers. Patient offset from the iso-centre ranged between -9 mm at the centre slice (abdomen level) to -43 mm at the most caudal slice at the pelvis (femur level), causing a significant magnification (p < 0.001) on 180°-localisers with a subsequent increase of the apparent attenuation. The results of this study emphasise the use of 0°-localisers in thoracoabdominal CTs, since 180°-localisers caused patient magnification with subsequent increase in radiation exposure. The advantage of 180°-localisers, namely reducing the dose in thyroid and breast, is eliminated if the dose of the CT scan increases significantly in the abdomen and pelvis.


Subject(s)
Radiation Exposure , Tomography, X-Ray Computed , Humans , Retrospective Studies , Tomography Scanners, X-Ray Computed , Patient Positioning
12.
Int J Cancer ; 150(11): 1861-1869, 2022 06 01.
Article in English | MEDLINE | ID: mdl-35076933

ABSTRACT

There is no generally accepted screening strategy for prostate cancer (PCa). From February 2014 to December 2019 a randomized trial (PROBASE) recruited 46 642 men at age 45 to determine the efficacy of risk-adapted prostate-specific antigen-based (PSA) screening, starting at either 45 or 50 years. PSA tests are used to classify participants into a low (<1.5 ng/mL), intermediate (1.5-2.99 ng/mL) or high (≥3 ng/mL) risk group. In cases of confirmed PSA values ≥3 ng/mL participants are recommended a prostate biopsy with multiparametric magnetic resonance imaging (mpMRI). Half of the participants (N = 23 341) were offered PSA screening immediately at age 45; the other half (N = 23 301) were offered digital rectal examination (DRE) with delayed PSA screening at age 50. Of 23 301 participants who accepted baseline PSA testing in the immediate screening arm, 89.2% fell into the low, 9.3% into intermediate, and 1.5% (N = 344) into the high risk group. Repeat PSA measurement confirmed high-risk status for 186 men (0.8%), of whom 120 (64.5%) underwent a biopsy. A total of 48 PCas was detected (overall prevalence 0.2%), of which 15 had International Society of Uropathology (ISUP) grade 1, 29 had ISUP 2 and only 4 had ISUP ≥3 cancers. In the delayed screening arm, 23 194 participants were enrolled and 6537 underwent a DRE with 57 suspicious findings, two of which showed PCa (both ISUP 1; detection rate 0.03%). In conclusion, the prevalence of screen-detected aggressive (ISUP ≥3) PCa in 45-year-old men is very low. DRE did not turn out effective for early detection of PCa.


Subject(s)
Early Detection of Cancer , Prostatic Neoplasms , Biopsy , Humans , Male , Mass Screening/methods , Middle Aged , Polymethyl Methacrylate , Prostate-Specific Antigen , Prostatic Neoplasms/diagnosis , Prostatic Neoplasms/epidemiology , Prostatic Neoplasms/prevention & control
13.
Eur J Nucl Med Mol Imaging ; 49(3): 992-1001, 2022 02.
Article in English | MEDLINE | ID: mdl-34476552

ABSTRACT

PURPOSE: To compare CT, MRI, and [18F]-fluorodeoxyglucose positron emission tomography ([18F]-FDG PET/MRI) for nodal status, regarding quantity and location of metastatic locoregional lymph nodes in patients with newly diagnosed breast cancer. MATERIALS AND METHODS: One hundred eighty-two patients (mean age 52.7 ± 11.9 years) were included in this prospective double-center study. Patients underwent dedicated contrast-enhanced chest/abdomen/pelvis computed tomography (CT) and whole-body ([18F]-FDG PET/) magnet resonance imaging (MRI). Thoracal datasets were evaluated separately regarding quantity, lymph node station (axillary levels I-III, supraclavicular, internal mammary chain), and lesion character (benign vs. malign). Histopathology served as reference standard for patient-based analysis. Patient-based and lesion-based analyses were compared by a McNemar test. Sensitivity, specificity, positive and negative predictive values, and accuracy were assessed for all three imaging modalities. RESULTS: On a patient-based analysis, PET/MRI correctly detected significantly more nodal positive patients than MRI (p < 0.0001) and CT (p < 0.0001). No statistically significant difference was seen between CT and MRI. PET/MRI detected 193 lesions in 75 patients (41.2%), while MRI detected 123 lesions in 56 patients (30.8%) and CT detected 104 lesions in 50 patients, respectively. Differences were statistically significant on a lesion-based analysis (PET/MRI vs. MRI, p < 0.0001; PET/MRI vs. CT, p < 0.0001; MRI vs. CT, p = 0.015). Subgroup analysis for different lymph node stations showed that PET/MRI detected significantly more lymph node metastases than MRI and CT in each location (axillary levels I-III, supraclavicular, mammary internal chain). MRI was superior to CT only in axillary level I (p = 0.0291). CONCLUSION: [18F]-FDG PET/MRI outperforms CT or MRI in detecting nodal involvement on a patient-based analysis and on a lesion-based analysis. Furthermore, PET/MRI was superior to CT or MRI in detecting lymph node metastases in all lymph node stations. Of all the tested imaging modalities, PET/MRI showed the highest sensitivity, whereas CT showed the lowest sensitivity, but was most specific.


Subject(s)
Breast Neoplasms , Fluorodeoxyglucose F18 , Adult , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Female , Humans , Magnetic Resonance Imaging , Middle Aged , Neoplasm Staging , Positron-Emission Tomography , Prospective Studies , Radiopharmaceuticals , Sensitivity and Specificity , Tomography, X-Ray Computed
14.
J Magn Reson Imaging ; 56(2): 413-422, 2022 08.
Article in English | MEDLINE | ID: mdl-35038203

ABSTRACT

BACKGROUND: Currently, multi-parametric prostate MRI (mpMRI) consists of a qualitative T2 , diffusion weighted, and dynamic contrast enhanced imaging. Quantification of T2 imaging might further standardize PCa detection and support artificial intelligence solutions. PURPOSE: To evaluate the value of T2 mapping to detect prostate cancer (PCa) and to differentiate PCa aggressiveness. STUDY TYPE: Retrospective single center cohort study. POPULATION: Forty-four consecutive patients (mean age 67 years; median PSA 7.9 ng/mL) with mpMRI and verified PCa by subsequent targeted plus systematic MR/ultrasound (US)-fusion biopsy from February 2019 to December 2019. FIELD STRENGTH/SEQUENCE: Standardized mpMRI at 3 T with an additionally acquired T2 mapping sequence. ASSESSMENT: Primary endpoint was the analysis of quantitative T2 values and contrast differences/ratios (CD/CR) between PCa and benign tissue. Secondary objectives were the correlation between T2 values, ISUP grade, apparent diffusion coefficient (ADC) value, and PI-RADS, and the evaluation of thresholds for differentiating PCa and clinically significant PCa (csPCa). STATISTICAL TESTS: Mann-Whitney test, Spearman's rank (rs ) correlation, receiver operating curves, Youden's index (J), and AUC were performed. Statistical significance was defined as P < 0.05. RESULTS: Median quantitative T2 values were significantly lower for PCa in PZ (85 msec) and PCa in TZ (75 msec) compared to benign PZ (141 msec) or TZ (97 msec) (P < 0.001). CD/CR between PCa and benign PZ (51.2/1.77), respectively TZ (19.8/1.29), differed significantly (P < 0.001). The best T2 -mapping threshold for PCa/csPCa detection was for TZ 81/86 msec (J = 0.929/1.0), and for PZ 110 msec (J = 0.834/0.905). Quantitative T2 values of PCa did not correlate significantly with the ISUP grade (rs  = 0.186; P = 0.226), ADC value (rs  = 0.138; P = 0.372), or PI-RADS (rs  = 0.132; P = 0.392). DATA CONCLUSION: Quantitative T2 values could differentiate PCa in TZ and PZ and might support standardization of mpMRI of the prostate. Different thresholds seem to apply for PZ and TZ lesions. However, in the present study quantitative T2 values were not able to indicate PCa aggressiveness. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.


Subject(s)
Prostate , Prostatic Neoplasms , Aged , Artificial Intelligence , Cohort Studies , Diffusion Magnetic Resonance Imaging/methods , Humans , Magnetic Resonance Imaging/methods , Male , Prostate/pathology , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Retrospective Studies
15.
World J Urol ; 40(2): 349-354, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34731264

ABSTRACT

PURPOSE: To evaluate the probability to correctly predict major vascular surgery (MVS) in patients undergoing postchemotherapy retroperitoneal lymph node dissection (PC-RPLND) for testicular cancer. METHODS: From a database of 504 RPLNDs performed in 434 patients (2008-2018), 78 patients submitted to PC-RPLND for non-seminoma germ-cell cancer after cisplatin-based chemotherapy with available preoperative CT scans were identified. Second PC-PLNDs (Re-Dos), salvage RPLNDs, or RPLNDs for late-relapse were excluded as well as thoraco-abdominal approaches. Preoperative imaging was reviewed by a urologist and a radiologist blinded to operative details. RESULTS: Of 78 patients, 16 (20.5%) underwent MVS (caval and/or aortic replacement or reconstruction). On univariable analyses, transversal diameter, sagittal diameter, tumor volume, aorta- and cava-tumor contact angle, poor IGCCCG score, clinical stage III and preoperative positive markers were predictors of MVS (all p values ≤ 0.01). At multivariable analyses aorta- (cut-off 64°) and cava-tumor contact angle (cut-off 98°) and poor IGCCCG score represented the three most important predictors of MVS (all p values ≤ 0.05). The model constructed has a PPV 100%, NPV 87% and an accuracy of 88%. CONCLUSIONS: Presence of aorta-tumor contact angle ≥ 64°, cava-tumor contact angle ≥ 98° and poor IGCCCG score identify correctly 9 out of 10 patients requiring MVS at the time of first PC-RPLND.


Subject(s)
Neoplasms, Germ Cell and Embryonal , Testicular Neoplasms , Humans , Lymph Node Excision/methods , Male , Neoplasm, Residual/surgery , Neoplasms, Germ Cell and Embryonal/diagnostic imaging , Neoplasms, Germ Cell and Embryonal/drug therapy , Neoplasms, Germ Cell and Embryonal/surgery , Retroperitoneal Space/surgery , Retrospective Studies , Testicular Neoplasms/diagnostic imaging , Testicular Neoplasms/drug therapy , Testicular Neoplasms/surgery , Vascular Surgical Procedures
16.
J Nucl Cardiol ; 29(2): 779-789, 2022 04.
Article in English | MEDLINE | ID: mdl-33025472

ABSTRACT

PURPOSE: Bone-tracer scintigraphy has an established role in diagnosis of cardiac amyloidosis (CA) as it detects transthyretin amyloidosis (ATTR). Positron emission tomography (PET) with amyloid tracers has shown high sensitivity for detection of both ATTR and light-chain (AL) CA. We aimed to investigate the accuracy of 18F-flutemetamol in CA. METHODS: We enrolled patients with CA or non-amyloid heart failure (NA-HF), who underwent cardiac 18F-flutemetamol PET/MRI or PET/CT. Myocardial and blood pool standardized tracer uptake values (SUV) were estimated. Late gadolinium enhancement (LGE) and T1 mapping/ extracellular volume (ECV) estimation were performed. RESULTS: We included 17 patients (12 with CA, 5 with NA-HF). PET/MRI was conducted in 13 patients, while PET/CT was conducted in 4. LGE was detected in 8 of 9 CA patients. Global relaxation time and ECV were higher in CA (1448 vs. 1326, P = 0.02 and 58.9 vs. 33.7%, P = 0.006, respectively). Positive PET studies were demonstrated in 2 of 12 patients with CA (AL and ATTR). Maximal and mean SUV did not differ between groups (2.21 vs. 1.69, P = 0.18 and 1.73 vs. 1.30, P = 0.13). CONCLUSION: Although protein-independent binding is supported by our results, the diagnostic yield of PET was low. We demonstrate here for the first time the low sensitivity of PET for CA.


Subject(s)
Amyloid Neuropathies, Familial , Cardiomyopathies , Heart Failure , Amyloid , Amyloid Neuropathies, Familial/diagnostic imaging , Aniline Compounds , Benzothiazoles , Cardiomyopathies/diagnostic imaging , Contrast Media , Gadolinium , Heart Failure/diagnostic imaging , Humans , Positron Emission Tomography Computed Tomography , Positron-Emission Tomography
17.
BMC Med Imaging ; 22(1): 63, 2022 04 04.
Article in English | MEDLINE | ID: mdl-35379187

ABSTRACT

PURPOSE: While 18F-FDG PET/CT yields valuable prognostic information for patients in first-line therapy of multiple myeloma (MM), its prognostic relevance in relapse is not established. Available studies of relapsed MM describe prognostic thresholds for frequently used PET/CT parameters that are significantly higher than those identified in the first-line setting. The purpose of this study was to evaluate the prognostic role of PET/CT in relapsed MM, based on parameters used in the first-line setting. METHODS: Our retrospective study included 36 patients with MM who had received autologous or allogeneic stem cell transplantation, suffered at least one relapse, and underwent FDG-PET/CT at relapse. Number of focal bone lesions (FL), maximal standardised uptake value (SUVmax), and presence of PET-positive extramedullary lesions (EMD) were analysed. RESULTS: For the number of FLs, the prognostic value was demonstrated with a cut-off of > 3 (median OS 3.8 months vs. not reached, p = 0.003). Median OS of patients with SUVmax ≤ 4 was not reached, while it was 3.9 months in patients with SUVmax > 4 (p = 0.014). Presence of EMD was a significant prognostic parameter too, with median OS of 3.6 months versus not reached (p = 0.004). The above-mentioned parameters showed prognostic significance for PFS as well. Combination of higher ISS stage and PET/CT parameters identified patients with particularly short OS (3.7 months vs. not reached, p < 0.001) and PFS (3.6 vs. 11.7 months p < 0.001). CONCLUSION: The PET/CT parameters SUVmax > 4, nFL > 3, and presence of EMD identify patients with poor prognosis not only in the first-line setting but also in relapsed MM.


Subject(s)
Fluorodeoxyglucose F18 , Multiple Myeloma , Humans , Multiple Myeloma/diagnostic imaging , Multiple Myeloma/drug therapy , Positron Emission Tomography Computed Tomography , Prognosis , Retrospective Studies
18.
Int J Mol Sci ; 23(18)2022 Sep 17.
Article in English | MEDLINE | ID: mdl-36142810

ABSTRACT

Sodium magnetic resonance imaging (MRI) can be used to evaluate the change in the proteoglycan content in Achilles tendons (ATs) of patients with different AT pathologies by measuring the 23Na signal-to-noise ratio (SNR). As 23Na SNR alone is difficult to compare between different studies, because of the high influence of hardware configurations and sequence settings on the SNR, we further set out to measure the apparent tissue sodium content (aTSC) in the AT as a better comparable parameter. Ten healthy controls and one patient with tendinopathy in the AT were examined using a clinical 3 Tesla (T) MRI scanner in conjunction with a dual tuned 1H/23Na surface coil to measure 23Na SNR and aTSC in their ATs. 23Na T1 and T2* of the AT were also measured for three controls to correct for different relaxation behavior. The results were as follows: 23Na SNR = 11.7 ± 2.2, aTSC = 82.2 ± 13.9 mM, 23Na T1 = 20.4 ± 2.4 ms, 23Na T2s* = 1.4 ± 0.4 ms, and 23Na T2l* = 13.9 ± 0.8 ms for the whole AT of healthy controls with significant regional differences. These are the first reported aTSCs and 23Na relaxation times for the AT using sodium MRI and may serve for future comparability in different studies regarding examinations of diseased ATs with sodium MRI.


Subject(s)
Achilles Tendon , Achilles Tendon/diagnostic imaging , Achilles Tendon/pathology , Humans , Magnetic Resonance Imaging/methods , Proteoglycans , Reproducibility of Results , Sodium
19.
Int J Mol Sci ; 23(13)2022 Jun 22.
Article in English | MEDLINE | ID: mdl-35805925

ABSTRACT

Based on in silico, in situ, and in vivo studies, this study aims to develop a new method for the quantitative chemical exchange saturation transfer (qCEST) technique considering multi-pool systems. To this end, we extended the state-of-the-art apparent exchange-dependent relaxation (AREX) method with a Lorentzian correction (LAREX). We then validated this new method with in situ and in vivo experiments on human intervertebral discs (IVDs) using the Kendall-Tau correlation coefficient. In the in silico experiments, we observed significant deviations of the AREX method as a function of the underlying exchange rate (kba) and fractional concentration (fb) compared to the ground truth due to the influence of other exchange pools. In comparison to AREX, the LAREX-based Ω-plot approach yielded a substantial improvement. In the subsequent in situ and in vivo experiments on human IVDs, no correlation to the histological reference standard or Pfirrmann classification could be found for the fb (in situ: τ = −0.17 p = 0.51; in vivo: τ = 0.13 p = 0.30) and kba (in situ: τ = 0.042 p = 0.87; in vivo: τ = −0.26 p = 0.04) of Glycosaminoglycan (GAG) with AREX. In contrast, the influence of interfering pools could be corrected by LAREX, and a moderate to strong correlation was observed for the fractional concentration of GAG for both in situ (τ = −0.71 p = 0.005) and in vivo (τ = −0.49 p < 0.001) experiments. The study presented here is the first to introduce a new qCEST method that enables qCEST imaging in systems with multiple proton pools.


Subject(s)
Intervertebral Disc , Magnetic Resonance Imaging , Glycosaminoglycans , Humans , Magnetic Resonance Imaging/methods , Protons
20.
J Radiol Prot ; 42(2)2022 Mar 09.
Article in English | MEDLINE | ID: mdl-35130526

ABSTRACT

To implement typical doses (TD) and typical values (TV) for fluoroscopic diagnostic and interventional procedures. A total of 3811 fluoroscopic procedures performed within 34 months on three devices were included in this retrospective study. Dose-, patient- and procedure-related information were extracted using the institutional dose management system (DMS). TD/TV were defined as median dose and calculated for the five most frequent procedures per device for dose area product (DAP), cumulative air kerma (CAK) and fluoroscopy time (FT). National diagnostic reference levels and other single facility studies were compared to our results. Additionally, the five procedures with the highest doses of each device were analysed. To evaluate the data coverage of the DMS compared to the picture archiving and communication system (PACS), procedure lists were extracted from the PACS and compared to the procedure information extracted from the DMS. TD/TV for 15 procedures were implemented. Among all devices, TD for DAP ranged between 0.6 Gycm2for port catheter control (n= 64) and 145.9 Gycm2for transarterial chemoembolisation (n= 84). TD for CAK ranged between 5 mGy for port catheter control and 1397 mGy for aneurysm treatment (n= 129) and TV for FT ranged between 0.3 min for upper cavography (n= 67) and 51.4 min for aneurysm treatment. TD for DAP and CAK were lower or within the range of other single facility studies. The five procedures with the highest median DAP per device were identified, 6 of 15 procedures were also found to be among the most frequent procedures. Data coverage of the DMS compared to the PACS ranged between 71% (device 2, stroke treatment) and 78% (device 1, lower limb angiography) for the most common procedure per device. Thus, in 22%-29% of cases dose data of the performed procedure was not transferred into the DMS. We implemented TD/TV for fluoroscopic diagnostic and interventional procedures which enable a comprehensive dose analysis and comparison with previously published values.


Subject(s)
Radiography, Interventional , Fluoroscopy , Humans , Radiation Dosage , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL