Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 710
Filter
1.
Anaesthesia ; 75(1): 37-44, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31556454

ABSTRACT

The inflationary non-invasive blood pressure monitor (iNIBP™) uses a new measurement method, whereby the cuff is slowly inflated whilst simultaneously sensing oscillations, to determine the diastolic blood pressure first and then the systolic pressure. It may measure blood pressure more quickly than the conventional non-invasive blood pressure monitor. We studied 66 patients undergoing general anaesthesia, comparing the time taken to measure the blood pressure between the two monitors at times when there were marked changes (increases or decreases by 30 mmHg or greater) in the systolic blood pressure. The median (IQR) [range]) time was significantly longer for the non-invasive blood pressure monitor (38.8 (31.5-44.7) [18.0-130.0] s) than for the iNIBP (14.6 (13.7-16.4) [11.5-35.5] s), p = 0.001, 95%CI for difference 22-25 s). We also studied 30 volunteers to evaluate the accuracy of the iNIBP, comparing it with the mercury sphygmomanometer. There was good agreement between the two monitors, with a mean difference of 0 (95% limit of agreement -12 to 11) mmHg for the systolic blood pressure. We also compared the degree of pain during cuff inflation between the automated non-invasive blood pressure and iNIBP monitors. Pain was significantly more for the non-invasive blood pressure monitor (22 of 30 volunteers had less pain with the iNIBP). We have shown that the iNIBP measured the blood pressure quicker than the conventional non-invasive blood pressure monitor and the speed of measurement was not significantly affected by marked changes in the blood pressure.


Subject(s)
Blood Pressure Determination/instrumentation , Blood Pressure Determination/methods , Cross-Over Studies , Equipment Design , Female , Humans , Male , Middle Aged , Reproducibility of Results , Time Factors
2.
Andrologia ; 50(7): e13024, 2018 Sep.
Article in English | MEDLINE | ID: mdl-29665107

ABSTRACT

Klinefelter syndrome is a condition in which a male patient has one Y chromosome and one or more extra X chromosomes. It is the most common sex chromosome disorder. Klinefelter syndrome is distinguished by many clinical features, such as infertility, high gonadotropin and low testosterone levels, increased height, and sparse body and facial hair. We report the case of a 32-year-old man who visited our hospital complaining of male infertility. Semen analysis showed azoospermia, and chromosomal analysis revealed a 47,XY,i(X)(q10) karyotype, which is a rare variant of Klinefelter syndrome. No spermatozoon was found on microdissection testicular sperm extraction, and the testis biopsy histology showed only Sertoli cells and hyalinised seminiferous tubules. 47,XY, i(X)(q10) has an additional isochromosome made of the long arm of the X chromosome, which shares some features of classical Klinefelter syndrome in many aspects, but patients are usually shorter than average height and have normal intelligence. In addition, to the best of our knowledge, no successful sperm extractions from 47,XY, i(X)(q10) patients were reported in the literature. The reports of patients who have undergone microdissection testicular sperm extraction are very rare. Further reports and studies of this chromosomal abnormality are needed.


Subject(s)
Azoospermia/genetics , Chromosome Aberrations , Chromosomes, Human, Y/genetics , Klinefelter Syndrome/genetics , Adult , Azoospermia/diagnosis , Azoospermia/pathology , Biopsy , Humans , Karyotype , Karyotyping , Klinefelter Syndrome/diagnosis , Klinefelter Syndrome/pathology , Male , Testis/pathology
3.
J Anesth ; 32(1): 132-136, 2018 02.
Article in English | MEDLINE | ID: mdl-29134423

ABSTRACT

Respiratory management during general anesthesia aims to safely secure the airway and maintain adequate ventilation to deliver oxygen to the vital organs, maintaining homeostasis even during surgery. Despite its clinical importance, anesthesiologists often encounter difficulties in properly managing respiration during the perioperative period, leading to severe respiratory complications. In this year's JA symposium, 5 editorial board members of Journal of Anesthesia (JA) who are experts in the field of respiratory management in anesthesia discussed the following topics: quitting smoking before surgery: exposure to passive smoke is damaging to children, ventilator-associated pneumonia, high inspiratory oxygen concentration and lung injury, aspiration pneumonia, and postoperative respiratory management strategy in patients with obstructive sleep apnea. We hope that this special article regarding this year's JA symposium may be useful for JA readers to manage clinical anesthesia on a daily basis.


Subject(s)
Anesthesia, General/methods , Perioperative Period , Postoperative Complications/epidemiology , Respiration Disorders/epidemiology , Child , Humans , Postoperative Period , Respiration , Respiratory System , Sleep Apnea, Obstructive/complications , Tobacco Smoke Pollution/adverse effects
4.
Br J Anaesth ; 117 Suppl 1: i83-i86, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27449997

ABSTRACT

BACKGROUND: The aim of this study was to propose and validate a new clinical score to predict difficult ventilation through a supraglottic airway device. METHODS: The score was proposed from our previously reported derivation data, and we prospectively validated the score in 5532 patients from November 2013 to April 2014. Predictive accuracy of the score was compared by the area under the receiver operating characteristic (ROC) curve (AUC). We assigned point values to each of the identified four risk factors: male, age >45 yr, short thyromental distance, and limited neck movement, their sum composing the score. The score ranged between 0 and 7 points. The optimal predictive level of the score was determined using ROC curve analysis. RESULTS: The AUC of the score was 0.75 (95% CI 0.66 to 0.84) in the validation data set, and was similar to that in the derivation data set (0.80; 95% CI 0.75 to 0.86). In derivation and validation data sets, the incidence of low risk categories (scores 0-3) was 0.42% vs 0.32% and of high risk categories (scores 4-7) was 3% vs 1.7% respectively. A score 4 or greater is associated with a six to seven fold increased risk of difficult ventilation through a supraglottic airway device. CONCLUSIONS: The new score for prediction of difficult ventilation through a supraglottic airway device is easy to perform and reliable, and could help anaesthetists plan for difficult airway management.


Subject(s)
Airway Management/methods , Laryngeal Masks , Respiration, Artificial/methods , Adult , Aged , Airway Management/instrumentation , Anesthesia, General/methods , Female , Humans , Male , Middle Aged , Point-of-Care Systems , Predictive Value of Tests , Prospective Studies , ROC Curve , Risk Assessment/methods , Risk Factors , Young Adult
5.
Anaesthesia ; 69(8): 878-82, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24866121

ABSTRACT

We studied 40 adult patients to see if cricoid pressure affected placement of the I-gel(™). In a randomised crossover design, the i-gel was placed with and without cricoid pressure, and we compared the success rate of adequate ventilation through the i-gel, time to placement and the rate of optimal position of the device between the two circumstances. Cricoid pressure significantly decreased the success rate of adequate ventilation through the i-gel (40 vs 34 patients) (p = 0.041, 95% CI for difference 4-26%), and significantly decreased the rate of the optimal position (39 vs 17 patients) (p < 0.001). The time to achieve adequate ventilation was significantly longer (p < 0.001) with cricoid pressure than without (median difference 8 s; 95% CI for median difference 3-12 s). Cricoid pressure significantly decreases the success rate of ventilation through the i-gel, but the success rate of ventilation through the i-gel is reasonably high.


Subject(s)
Cricoid Cartilage/physiology , Elastomers , Laryngeal Masks , Adult , Aged , Aged, 80 and over , Cross-Over Studies , Female , Humans , Male , Middle Aged , Pressure
6.
Rev Sci Tech ; 33(3): 1007-15, 2014 12.
Article in English | MEDLINE | ID: mdl-25812223

ABSTRACT

The use of veterinary antimicrobial agents in animals can result in the emergence and selection of resistant bacteria in food-producing animals. This study elucidated the use of veterinary antimicrobial agents in Japan in terms of milligrams of active ingredient sold per kilogram of biomass between 2005 and 2010. Data on sales of antimicrobial agents and on the biomass of the target animal species were compiled from statistics published bythe Japanese Ministry of Agriculture, Forestry and Fisheries. The quantities of antimicrobials used varied between animal species: the highest usage was observed in pigs (392 to 423 mg/ kg), followed by beef cattle (45 to 67 mg/kg), broiler chickens (44 to 63 mg/kg) and dairy cattle (33 to 49 mg/kg). For the animal species combined, usage of third- and fourth-generation cefalosporins, fluoroquinolones and macrolides ranged from 0.10 to 0.14 mg/kg biomass, 1.1 to 1.3 mg/kg biomass and 7.8 to 10.6 mg/kg biomass, respectively.


Subject(s)
Anti-Bacterial Agents/therapeutic use , Commerce/statistics & numerical data , Drug Utilization/statistics & numerical data , Veterinary Drugs/economics , Animals , Anti-Bacterial Agents/economics , Cattle , Chickens , Commerce/trends , Drug Utilization/trends , Japan , Swine
7.
Rev Sci Instrum ; 95(3)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38436451

ABSTRACT

Solid-state nuclear track detectors (SSNTDs) are often used as ion detectors in laser-driven ion acceleration experiments and are considered to be the most reliable ion diagnostics since they are sensitive only to ions and measure ions one by one. However, ion pit analyses require tremendous time and effort in chemical etching, microscope scanning, and ion pit identification by eyes. From a laser-driven ion acceleration experiment, there are typically millions of microscopic images, and it is practically impossible to analyze all of them by hand. This research aims to improve the efficiency and automation of SSNTD analyses for laser-driven ion acceleration. We use two sets of data obtained from calibration experiments with a conventional accelerator where ions with known nuclides and energies are generated and from actual laser experiments using SSNTDs. After chemical etching and scanning the SSNTDs with an optical microscope, we use machine learning to distinguish the ion etch pits from noises. From the results of the calibration experiment, we confirm highly accurate etch-pit detection with machine learning. We are also able to detect etch pits with machine learning from the laser-driven ion acceleration experiment, which is much noisier than calibration experiments. By using machine learning, we successfully identify ion etch pits ∼105 from more than 10 000 microscopic images with a precision of ≳95%. A million microscopic images can be examined with a recent entry-level computer within a day with high precision. Machine learning tremendously reduces the time consumption on ion etch pit analyses detected on SSNTDs.

11.
Poult Sci ; 92(2): 375-81, 2013 Feb.
Article in English | MEDLINE | ID: mdl-23300304

ABSTRACT

Campylobacter jejuni was monitored in 4 chicken farms during the period 2003 to 2006 to elucidate the mechanisms of transmission. Three farms (1 to 3), located at least 14 km from each other, belonged to an integrated poultry company, which also provided the farms with day-old chicks from several hatcheries as well as chicken feed. Another farm (4), which belonged to a different company, was located 270 m from farm 1. A total of 206 C. jejuni isolates obtained from the 4 farms were classified into 10 flaA-based RFLP types. Identical RFLP types were found in isolates obtained from chickens originating from multiple hatcheries and reared in different chicken houses on individual farms. Flocks were colonized by strains with 1 or 2 RFLP types in each production cycle, sometimes differing between cycles. Identical RFLP types were found in isolates obtained from the environment around the chicken houses. Using multilocus sequence typing, strains with different RFLP types could be distinguished from each other. Identical RFLP and multilocus sequence typing profiles were found in isolates obtained from farms 1 and 4, and from farms 1 and 2. These results suggest that C. jejuni in these farms comes from common sources external to the farms, even if the farms belong to different companies and obtain chicks from different suppliers.


Subject(s)
Campylobacter Infections/veterinary , Campylobacter jejuni/genetics , Chickens , Flagellin/genetics , Polymorphism, Restriction Fragment Length , Poultry Diseases/transmission , Animals , Bacterial Typing Techniques/veterinary , Campylobacter Infections/transmission , Campylobacter jejuni/classification , Campylobacter jejuni/isolation & purification , Japan , Multilocus Sequence Typing/veterinary , Polymerase Chain Reaction/veterinary
12.
Epidemiol Infect ; 140(11): 2074-81, 2012 Nov.
Article in English | MEDLINE | ID: mdl-22281015

ABSTRACT

This study determined the prevalence and antimicrobial susceptibility of Salmonella isolated from broiler flocks in Japan. Caecal dropping samples were collected from 288 broiler flocks between November 2007 and February 2010. Salmonella was prevalent in 248 (86·1%) broiler flocks. The top three serovars were S. Infantis, S. Manhattan and S. Schwarzengrund. S. Infantis was found in all regions tested in this study. However, S. Manhattan and S. Schwarzengrund were frequently found only in the western part of Japan. High antimicrobial resistance rates were observed against oxytetracycline (90·2%), dihydrostreptomycin (86·7%) and ampicillin (36·5%), and 258 (90·5%) of 285 isolates were resistant to two or more antimicrobial agents. Interestingly, 26·3% of isolates were resistant to ceftiofur, especially 38·1% of S. Infantis isolates, although its use in broilers has not been approved in Japan. This study showed that Salmonella is highly prevalent (86·1%) in Japanese broiler flocks, that 90·5% of Salmonella isolates were multidrug-resistant, and that S. Infantis frequently exhibited resistance to cephalosporin antimicrobial agents.


Subject(s)
Chickens , Drug Resistance, Bacterial , Poultry Diseases/epidemiology , Salmonella Infections, Animal/epidemiology , Salmonella enterica/drug effects , Ampicillin/pharmacology , Animals , Anti-Bacterial Agents/pharmacology , Cephalosporins/pharmacology , Dihydrostreptomycin Sulfate/pharmacology , Drug Resistance, Multiple, Bacterial , Feces/microbiology , Japan/epidemiology , Microbial Sensitivity Tests , Oxytetracycline/pharmacology , Poultry Diseases/microbiology , Salmonella Infections, Animal/microbiology , Salmonella enterica/isolation & purification
13.
Epidemiol Infect ; 140(6): 982-90, 2012 Jun.
Article in English | MEDLINE | ID: mdl-21849097

ABSTRACT

Human salmonellosis cases, particularly those caused by Salmonella Enteritidis, have been closely linked to egg consumption. This epidemiological survey was conducted to determine the baseline Salmonella prevalence and identify the risk factors for Salmonella prevalence in laying-hen farms in Japan. Caecal excrement samples and dust samples were obtained from 400 flocks in 338 laying-hen farms. Salmonella was identified in 20.7% of the farms and 19.5% of the flocks. The prevalence of Salmonella was significantly higher in flocks reared in windowless houses than in those reared in open houses. In addition, the risk of Salmonella presence was significantly higher when the windowless house farms implemented induced moulting or in-line egg processing. Efforts to reduce human salmonellosis in Japan should continue to focus on the establishment of control measures in laying-hen farms, especially those with windowless houses implementing induced moulting and equipped with in-line egg processing.


Subject(s)
Animal Husbandry , Chickens , Housing, Animal , Poultry Diseases/microbiology , Salmonella Infections, Animal/epidemiology , Animals , Cecum , Dust , Environmental Microbiology , Female , Gastrointestinal Contents/microbiology , Humans , Japan/epidemiology , Oviposition , Poultry Diseases/epidemiology , Risk Factors
14.
Rev Sci Instrum ; 93(10): 103520, 2022 Oct 01.
Article in English | MEDLINE | ID: mdl-36319387

ABSTRACT

A visible light tomographic imaging system has been developed for the collisional merging experiment of field-reversed configurations (FRCs) on the FRC Amplification via Translation-Collisional Merging device at Nihon University. Two FRCs formed by field-reversed theta-pinch translate at super-Alfvénic velocity and collide with each other. The translation and collision processes are completed in 20-30 µs, and a single FRC is reformed in ∼70 µs. To study these translation and collisional merging processes, the tomographic system, including fast response tomographic cameras and a reconstruction method assuming a Rigid-Rotor (RR) model, is developed. The developed tomographic cameras simply consist of 16 channels of multi-anode photomultipliers, a band-pass filter, a slit, and a cylindrical lens, which expands the viewing angle. Because the viewing angle is limited by the size of the viewports of the metal chamber, the iterative method assuming the RR model has been applied to reconstruct tomographic images from a small number of projections. The developed tomographic imaging system can estimate the behavior of FRCs. Four cameras are installed in the two cross sections near the collision point. The radial shift of each translated FRC can be calculated by this system. Details of the developed tomographic camera system and RR reconstruction method are reported.

15.
Rev Sci Instrum ; 93(12): 123512, 2022 Dec 01.
Article in English | MEDLINE | ID: mdl-36586891

ABSTRACT

A double-chord ion Doppler spectroscopy (IDS) system was developed to measure the ion temperature and flow velocity of field-reversed configuration (FRC) plasmas in the FRC amplification via a translation-collisional merging (FAT-CM) device. Adopting a Czerny-Turner mount monochromator and 16-channel photomultiplier tube array, the developed IDS system achieves high wavelength resolution and fast time response. In addition, two vertically aligned optical paths share the optical system up to the monochromator and then branch just before the detector, successfully reducing crosstalk to <1%. The Doppler broadening was measured at two measurement points in the FAT-CM device, simultaneously, and ion temperatures of ∼50 eV were measured. Toroidal spin-up from 7 to 15 km/s and a steady flow velocity of ∼10 km/s were estimated from the Doppler shift obtained by the developed system. The observation of the toroidal flow velocity and the spatial profile of the ion temperature of the FRC plasma in the FAT-CM device were realized. These spectroscopic diagnostic's double chord capabilities will aid in understanding and improving the FRC plasmas.

16.
Rev Sci Instrum ; 93(10): 103526, 2022 Oct 01.
Article in English | MEDLINE | ID: mdl-36319347

ABSTRACT

Visualization of the collisional merging formation process of field-reversed configuration (FRC) has been attempted. In the collisional merging formation process, two initial FRC-like plasmoids are accelerated toward each other by a magnetic pressure gradient. The relative speed of the collision reaches several times the typical ion sonic speed and Alfvénic speed. The magnetic structure of the initial-FRCs is disrupted in the collision process, but the FRC-like magnetic structure is reformed in ∼30 µs after the collision. Magnetic reconnection should occur in this process; however, general theoretical models in magnetohydrodynamics approximation cannot be applied to this process because of the high-beta nature of FRC and super-Alfvénic/sonic relative speed. In this work, the spectroscopic observation of the collisional merging FRC formation was conducted to evaluate the timescale and geometry of merging. A slight amount of tracer element (e.g., helium) was mixed into one of two initial-FRCs. Mixing of the tracer did not cause serious adverse effects on the performance of the initial-FRC in the collision and merging processes. The collision and merging processes were visualized successfully and observed using a fast-framing camera with a bandpass filter. The timescale of merging and the outflow speed in the collisional merging process of FRCs were optically evaluated for the first time.

17.
Rev Sci Instrum ; 93(6): 063502, 2022 Jun 01.
Article in English | MEDLINE | ID: mdl-35778001

ABSTRACT

Particle counting analysis (PCA) with a multi-stage scintillation detector shows a new perspective on angularly resolved spectral characterization of GeV-scale, multi-species ion beams produced by high-power lasers. The diagnosis provides a mass-dependent ion energy spectrum based on time-of-flight and pulse-height analysis of single particle events detected through repetitive experiments. With a novel arrangement of multiple scintillators with different ions stopping powers, PCA offers potential advantages over commonly used diagnostic instruments (CR-39, radiochromic films, Thomson parabola, etc.) in terms of coverage solid angle, detection efficiency for GeV-ions, and real-time analysis during the experiment. The basic detector unit was tested using 230-MeV proton beam from a synchrotron facility, where we demonstrated its potential ability to discriminate major ion species accelerated in laser-plasma experiments (i.e., protons, deuterons, carbon, and oxygen ions) with excellent energy and mass resolution. The proposed diagnostic concept would be essential for a better understanding of laser-driven particle acceleration, which paves the way toward all-optical compact accelerators for a range of applications.

18.
Rev Sci Instrum ; 93(11): 113530, 2022 Nov 01.
Article in English | MEDLINE | ID: mdl-36461420

ABSTRACT

Particle counting analysis is a possible way to characterize GeV-scale, multi-species ions produced in laser-driven experiments. We present a multi-layered scintillation detector to differentiate multi-species ions of different masses and energies. The proposed detector concept offers potential advantages over conventional diagnostics in terms of (1) high sensitivity to GeV ions, (2) realtime analysis, and (3) the ability to differentiate ions with the same charge-to-mass ratio. A novel choice of multiple scintillators with different ion stopping powers results in a significant difference in energy deposition between the scintillators, allowing accurate particle identification in the GeV range. Here, we report a successful demonstration of particle identification for heavy ions, performed at the Heavy Ion Medical Accelerator in Chiba. In the experiment, the proposed detector setup showed the ability to differentiate particles with similar atomic numbers, such as C6+ and O8+ ions, and provided an excellent energy resolution of 0.41%-1.2% (including relativistic effect, 0.51%--1.6%).

19.
Sci Rep ; 12(1): 2346, 2022 Feb 16.
Article in English | MEDLINE | ID: mdl-35173182

ABSTRACT

Graphene is known as an atomically thin, transparent, highly electrically and thermally conductive, light-weight, and the strongest 2D material. We investigate disruptive application of graphene as a target of laser-driven ion acceleration. We develop large-area suspended graphene (LSG) and by transferring graphene layer by layer we control the thickness with precision down to a single atomic layer. Direct irradiations of the LSG targets generate MeV protons and carbons from sub-relativistic to relativistic laser intensities from low contrast to high contrast conditions without plasma mirror, evidently showing the durability of graphene.

20.
Opt Express ; 19(11): 10387-409, 2011 May 23.
Article in English | MEDLINE | ID: mdl-21643295

ABSTRACT

A secure communication network with quantum key distribution in a metropolitan area is reported. Six different QKD systems are integrated into a mesh-type network. GHz-clocked QKD links enable us to demonstrate the world-first secure TV conferencing over a distance of 45km. The network includes a commercial QKD product for long-term stable operation, and application interface to secure mobile phones. Detection of an eavesdropper, rerouting into a secure path, and key relay via trusted nodes are demonstrated in this network.

SELECTION OF CITATIONS
SEARCH DETAIL