Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 113
Filter
1.
Circulation ; 149(9): 644-655, 2024 02 27.
Article in English | MEDLINE | ID: mdl-37883682

ABSTRACT

BACKGROUND: The optimal treatment in patients with severe aortic stenosis and small aortic annulus (SAA) remains to be determined. This study aimed to compare the hemodynamic and clinical outcomes between transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) in patients with a SAA. METHODS: This prospective multicenter international randomized trial was performed in 15 university hospitals. Participants were 151 patients with severe aortic stenosis and SAA (mean diameter <23 mm) randomized (1:1) to TAVR (n=77) versus SAVR (n=74). The primary outcome was impaired valve hemodynamics (ie, severe prosthesis patient mismatch or moderate-severe aortic regurgitation) at 60 days as evaluated by Doppler echocardiography and analyzed in a central echocardiography core laboratory. Clinical events were secondary outcomes. RESULTS: The mean age of the participants was 75.5±5.1 years, with 140 (93%) women, a median Society of Thoracic Surgeons predicted risk of mortality of 2.50% (interquartile range, 1.67%-3.28%), and a median annulus diameter of 21.1 mm (interquartile range, 20.4-22.0 mm). There were no differences between groups in the rate of severe prosthesis patient mismatch (TAVR, 4 [5.6%]; SAVR, 7 [10.3%]; P=0.30) and moderate-severe aortic regurgitation (none in both groups). No differences were found between groups in mortality rate (TAVR, 1 [1.3%]; SAVR, 1 [1.4%]; P=1.00) and stroke (TAVR, 0; SAVR, 2 [2.7%]; P=0.24) at 30 days. After a median follow-up of 2 (interquartile range, 1-4) years, there were no differences between groups in mortality rate (TAVR, 7 [9.1%]; SAVR, 6 [8.1%]; P=0.89), stroke (TAVR, 3 [3.9%]; SAVR, 3 [4.1%]; P=0.95), and cardiac hospitalization (TAVR, 15 [19.5%]; SAVR, 15 [20.3%]; P=0.80). CONCLUSIONS: In patients with severe aortic stenosis and SAA (women in the majority), there was no evidence of superiority of contemporary TAVR versus SAVR in valve hemodynamic results. After a median follow-up of 2 years, there were no differences in clinical outcomes between groups. These findings suggest that the 2 therapies represent a valid alternative for treating patients with severe aortic stenosis and SAA, and treatment selection should likely be individualized according to baseline characteristics, additional anatomical risk factors, and patient preference. However, the results of this study should be interpreted with caution because of the limited sample size leading to an underpowered study, and need to be confirmed in future larger studies. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03383445.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Male , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/etiology , Prospective Studies , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects , Risk Factors , Stroke/etiology
2.
Eur Heart J ; 45(21): 1904-1916, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38554125

ABSTRACT

BACKGROUND AND AIMS: There is significant potential to streamline the clinical pathway for patients undergoing transcatheter aortic valve implantation (TAVI). The purpose of this study was to evaluate the effect of implementing BENCHMARK best practices on the efficiency and safety of TAVI in 28 sites in 7 European countries. METHODS: This was a study of patients with severe symptomatic aortic stenosis (AS) undergoing TAVI with balloon-expandable valves before and after implementation of BENCHMARK best practices. Principal objectives were to reduce hospital length of stay (LoS) and duration of intensive care stay. Secondary objective was to document patient safety. RESULTS: Between January 2020 and March 2023, 897 patients were documented prior to and 1491 patients after the implementation of BENCHMARK practices. Patient characteristics were consistent with a known older TAVI population and only minor differences. Mean LoS was reduced from 7.7 ± 7.0 to 5.8 ± 5.6 days (median 6 vs. 4 days; P < .001). Duration of intensive care was reduced from 1.8 to 1.3 days (median 1.1 vs. 0.9 days; P < .001). Adoption of peri-procedure best practices led to increased use of local anaesthesia (96.1% vs. 84.3%; P < .001) and decreased procedure (median 47 vs. 60 min; P < .001) and intervention times (85 vs. 95 min; P < .001). Thirty-day patient safety did not appear to be compromised with no differences in all-cause mortality (0.6% in both groups combined), stroke/transient ischaemic attack (1.4%), life-threatening bleeding (1.3%), stage 2/3 acute kidney injury (0.7%), and valve-related readmission (1.2%). CONCLUSIONS: Broad implementation of BENCHMARK practices contributes to improving efficiency of TAVI pathway reducing LoS and costs without compromising patient safety.


Subject(s)
Aortic Valve Stenosis , Benchmarking , Length of Stay , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Male , Female , Aged, 80 and over , Length of Stay/statistics & numerical data , Aged , Critical Pathways , Europe/epidemiology , Postoperative Complications/epidemiology , Postoperative Complications/prevention & control , Patient Safety
3.
Vet Radiol Ultrasound ; 65(2): 76-86, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38183621

ABSTRACT

Published studies on the validity of using quantitative MRI measures of pre- and postoperative spinal cord (SC) compression as prognostic indicators for dogs undergoing surgery for intervertebral disc extrusion (IVDE) are currently limited. The aim of this retrospective analytical study was to describe the volume of postoperative residual extradural material (VREM) and the ratio of the cross-sectional area (CSA) of maximum SC compression to the CSA of SC in a compression-free intervertebral space as MRI measures of preoperative and postoperative compression (residual spinal cord compression, RSCC), and to compare these measures between the neurological outcome in a group of dogs. Inclusion criteria were dogs that underwent surgery for thoracolumbar IVDE, were imaged pre- and immediately postoperatively by MRI, and had a neurological follow-up examination 2 to 5 weeks postoperatively. Two blinded observers independently performed measurements in pre- and postoperative MRI studies. Dogs were classified into positive outcome (PO) and negative outcome (NO) groups based on follow-up neurologic examination scores. Seventeen dogs were included (12 PO, 5 NO). Interobserver agreement for MRI measurements was good to excellent (ICCs: 0.76-0.97). The prevalence of residual extradural material in postoperative MRI studies was 100%. No significant differences in mean preoperative SC compression, mean RSCC, mean SC decompression, or VREM were found between outcome groups (P = .25; P = .28; P = .91, P = .98). In conclusion, neither postoperative VREM nor RSCC could predict successful neurological outcomes.


Subject(s)
Dog Diseases , Intervertebral Disc Displacement , Intervertebral Disc , Spinal Cord Compression , Dogs , Animals , Spinal Cord Compression/diagnostic imaging , Spinal Cord Compression/surgery , Spinal Cord Compression/veterinary , Retrospective Studies , Residual Volume , Dog Diseases/diagnostic imaging , Dog Diseases/surgery , Intervertebral Disc Displacement/diagnostic imaging , Intervertebral Disc Displacement/surgery , Intervertebral Disc Displacement/veterinary , Magnetic Resonance Imaging/veterinary
4.
Can Vet J ; 65(6): 559-564, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38827593

ABSTRACT

A 3-month-old female English setter dog was presented to the Faculty of Veterinary Medicine of the Université de Montréal (Quebec) with acute respiratory distress. The dog had moderately increased C-reactive protein concentrations, and thoracic radiographs revealed a moderate, caudodorsal, nodular-to-miliary alveolo-interstitial pulmonary pattern that was worse in the perihilar region. Initial differential diagnoses included a fungal pneumonia (e.g., blastomycosis or histoplasmosis). Cytology of the bronchoalveolar lavage revealed several round, green structures ~2 µm in diameter, consistent with fungal spores. The dog was hospitalized, but within 24 h the respiratory condition deteriorated and euthanasia was elected. Post-mortem panfungal PCR and sequencing tests identified the spores as Lycoperdon sp. Retrospectively, the owners recalled that the dog had played in a wood pile with mushrooms and had sneezed in a cloud of spores, implying inhalation of Lycoperdon spores. This is the first report of a confirmed case of canine lycoperdonosis in eastern Canada (Quebec), and the radiographic features in this case differed slightly from previous reports. Diagnosis before bronchoalveolar lavage analysis was challenging, as spore inhalation was not initially reported. Although the disease is infrequently reported in dogs, this case report reminds veterinarians to consider lycoperdonosis as a differential diagnosis when addressing animals presented with acute dyspnea with similar radiographic lesions, and highlights the importance of history and cytology in diagnosing this condition. Key clinical message: Hypersensitivity pneumonitis secondary to inhalation of Lycoperdon spores must be included in differential diagnoses for a dog with acute onset of respiratory signs and a nodular-to-miliary interstitial pulmonary pattern coalescing in patchy perihilar alveolar pulmonary lesions, and should prompt clinicians to question owners regarding inhalation of mushroom spores.Although cytological examination of a bronchoalveolar lavage reveals the presence of fungal spores, panfungal PCR and sequencing tests are needed to pinpoint the species involved.


Pneumopathie d'hypersensibilité associée à l'inhalation de spores de Lycoperdon (lycoperdonose) chez un chien setter anglais de 3 mois au Québec. Une chienne setter anglais âgée de 3 mois a été présentée à la Faculté de médecine vétérinaire de l'Université de Montréal (Québec) avec une détresse respiratoire aiguë. Le chien présentait des concentrations de protéine C-réactive modérément augmentées et les radiographies thoraciques ont révélé un schéma pulmonaire alvéolo-interstitiel modéré, caudodorsal, nodulaire à miliaire, pire dans la région périhilaire. Les diagnostics différentiels initiaux incluaient une pneumonie fongique (par exemple, blastomycose ou histoplasmose). La cytologie du lavage broncho-alvéolaire a révélé plusieurs structures rondes et vertes d'environ 2 µm de diamètre, compatibles avec des spores fongiques. Le chien a été hospitalisé, mais en 24 heures, l'état respiratoire s'est détérioré et l'euthanasie a été décidée. Les tests panfongiques PCR et de séquençage post-mortem ont identifié les spores comme étant Lycoperdon sp. Rétrospectivement, les propriétaires ont mentionné que le chien avait joué dans un tas de bois avec des champignons et avait éternué dans un nuage de spores, ce qui implique une inhalation de spores de Lycoperdon. Il s'agit du premier rapport d'un cas confirmé de lycoperdonose canine dans l'est du Canada (Québec), et les caractéristiques radiographiques de ce cas différaient légèrement des rapports précédents. Le diagnostic avant l'analyse du lavage broncho-alvéolaire était difficile, car l'inhalation de spores n'avait pas été initialement signalée. Bien que la maladie soit rarement rapportée chez les chiens, ce rapport de cas rappelle aux vétérinaires de considérer la lycoperdonose comme un diagnostic différentiel lorsqu'ils traitent des animaux présentant une dyspnée aiguë avec des lésions radiographiques similaires, et souligne l'importance de l'anamnèse et de la cytologie dans le diagnostic de cette affection.Message clinique clé : La pneumopathie d'hypersensibilité secondaire à l'inhalation de spores de Lycoperdon doit être incluse dans les diagnostics différentiels chez un chien présentant un début aigu de signes respiratoires et un schéma pulmonaire interstitiel nodulaire à miliaire fusionnant dans des lésions pulmonaires alvéolaires périhilaires inégales, et devrait inciter les cliniciens à interroger les propriétaires concernant l'inhalation de spores de champignons.Bien que l'examen cytologique d'un lavage broncho-alvéolaire révèle la présence de spores fongiques, des tests panfongiques PCR et de séquençage sont nécessaires pour identifier les espèces impliquées.(Traduit par Dr Serge Messier).


Subject(s)
Alveolitis, Extrinsic Allergic , Dog Diseases , Spores, Fungal , Animals , Dogs , Dog Diseases/microbiology , Dog Diseases/diagnosis , Female , Alveolitis, Extrinsic Allergic/veterinary , Alveolitis, Extrinsic Allergic/diagnosis , Spores, Fungal/isolation & purification , Quebec
5.
Clin Infect Dis ; 76(6): 1003-1012, 2023 03 21.
Article in English | MEDLINE | ID: mdl-36331961

ABSTRACT

BACKGROUND: Echocardiography is the primary imaging modality for diagnosis of infective endocarditis (IE) in prosthetic valve endocarditis (PVE) including IE after transcatheter aortic valve implantation (TAVI). This study aimed to evaluate the characteristics and clinical outcomes of patients with absent compared with evident echocardiographic signs of TAVI-IE. METHODS: Patients with definite TAVI-IE derived from the Infectious Endocarditis after TAVI International Registry were investigated comparing those with absent and evident echocardiographic signs of IE defined as vegetation, abscess, pseudo-aneurysm, intracardiac fistula, or valvular perforation or aneurysm. RESULTS: Among 578 patients, 87 (15.1%) and 491 (84.9%) had absent (IE-neg) and evident (IE-pos) echocardiographic signs of IE, respectively. IE-neg were more often treated via a transfemoral access with a self-expanding device and had higher rates of peri-interventional complications (eg, stroke, major vascular complications) during the TAVI procedure (P < .05 for all). IE-neg had higher rates of IE caused by Staphylococcus aureus (33.7% vs 23.2%; P = .038) and enterococci (37.2% vs 23.8%; P = .009) but lower rates of coagulase-negative staphylococci (4.7% vs 20.0%, P = .001). IE-neg was associated with the same dismal prognosis for in-hospital mortality in a multivariate binary regression analysis (odds ratio: 1.51; 95% confidence interval [CI]: .55-4.12) as well as a for 1-year mortality in Cox regression analysis (hazard ratio: 1.10; 95% CI: .67-1.80). CONCLUSIONS: Even with negative echocardiographic imaging, patients who have undergone TAVI and presenting with positive blood cultures and symptoms of infection are a high-risk patient group having a reasonable suspicion of IE and the need for an early treatment initiation.


Subject(s)
Endocarditis, Bacterial , Endocarditis , Heart Valve Prosthesis , Prosthesis-Related Infections , Transcatheter Aortic Valve Replacement , Humans , Endocarditis, Bacterial/diagnostic imaging , Endocarditis, Bacterial/epidemiology , Endocarditis, Bacterial/etiology , Transcatheter Aortic Valve Replacement/adverse effects , Incidence , Risk Factors , Prosthesis-Related Infections/diagnostic imaging , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/etiology , Endocarditis/diagnostic imaging , Endocarditis/epidemiology , Echocardiography
6.
Br J Dermatol ; 189(4): 368-380, 2023 09 15.
Article in English | MEDLINE | ID: mdl-37410552

ABSTRACT

BACKGROUND: On the basis of safety data for patients with inflammatory rheumatism or inflammatory bowel disease, treatment with Janus kinase (JAK) inhibitors (JAKi) has been linked to the occurrence of major adverse cardiovascular events (MACE). However, these inflammatory diseases are proatherogenic; in contrast, patients with atopic dermatitis (AD) do not usually have a high cardiovascular (CV) comorbidity burden. OBJECTIVES: To perform a systematic review and meta-analysis of MACE in patients with AD treated with JAKi. METHODS: We systematically searched PubMed, Embase, Cochrane Library and Google Scholar from their inception to 2 September 2022. Cohort studies, randomized controlled trials and pooled safety analyses providing CV safety data on patients taking JAKi for AD were selected. We included patients aged ≥ 12 years. We built a 'controlled-period' cohort (n = 9309; 6000 exposed to JAKi and 3309 exposed to comparators) and an 'all-JAKi' cohort (n = 9118 patients exposed to a JAKi in any of the included studies). The primary outcome was a composite of acute coronary syndrome (ACS), ischaemic stroke and CV death. The broader secondary MACE outcome encompassed ACS, stroke (whether ischaemic or haemorrhagic), transient ischaemic attack and CV death. The frequency of primary and secondary MACE was assessed in both cohorts. A fixed-effects meta-analysis using the Peto method was used to calculate the odds ratio (OR) for MACE in the 'controlled-period' cohort. Evaluation of the risk of bias was done using the Cochrane risk-of-bias tool (version 2). Certainty of evidence was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. RESULTS: Eight per cent of the records identified initially met the selection criteria, corresponding to 23 records included in the 'all-JAKi' cohort. Patients had been exposed to baricitinib, upadacitinib, abrocitinib, ivarmacitinib, placebo or dupilumab. Four primary events (three with JAKi and one with placebo) and five secondary events (four with JAKi and one with placebo) occurred among 9309 patients in the 'controlled-period' cohort (MACE frequency 0.04% and 0.05%, respectively). Eight primary events and 13 secondary events occurred among 9118 patients in the 'all-JAKi' cohort (MACE frequency 0.08% and 0.14%, respectively). The OR for primary MACE in patients with AD treated with JAKi vs. placebo or dupilumab was 1.35 (95% confidence interval 0.15-12.21; I2 = 12%, very low certainty of evidence). CONCLUSIONS: Our review highlights rare cases of MACE among JAKi users for AD. JAKi may have little-to-no effect on the occurrence of MACE in patients with AD vs. comparators, but the evidence is uncertain. Real-life long-term population-level safety studies are needed.


Subject(s)
Brain Ischemia , Dermatitis, Atopic , Inflammatory Bowel Diseases , Janus Kinase Inhibitors , Stroke , Humans , Janus Kinase Inhibitors/adverse effects , Dermatitis, Atopic/drug therapy , Brain Ischemia/chemically induced , Brain Ischemia/drug therapy , Inflammatory Bowel Diseases/drug therapy
7.
Clin Infect Dis ; 75(4): 638-646, 2022 09 10.
Article in English | MEDLINE | ID: mdl-34894124

ABSTRACT

BACKGROUND: Infective endocarditis (IE) following transcatheter aortic valve replacement (TAVR) has been associated with a dismal prognosis. However, scarce data exist on IE perivalvular extension (PEE) in such patients. METHODS: This multicenter study included 579 patients who had the diagnosis of definite IE at a median of 171 (53-421) days following TAVR. PEE was defined as the presence of an intracardiac abscess, pseudoaneurysm, or fistula. RESULTS: A total of 105 patients (18.1%) were diagnosed with PEE (perivalvular abscess, pseudoaneurysm, fistula, or a combination in 87, 7, 7, and 4 patients, respectively). A history of chronic kidney disease (adjusted odds ratio [ORadj], 2.08; 95% confidence interval [CI]: 1.27-3.41; P = .003) and IE secondary to coagulase-negative staphylococci (ORadj, 2.71; 95% CI: 1.57-4.69; P < .001) were associated with an increased risk of PEE. Surgery was performed at index IE episode in 34 patients (32.4%) with PEE (vs 15.2% in patients without PEE, P < .001). In-hospital and 2-year mortality rates among PEE-IE patients were 36.5% and 69.4%, respectively. Factors independently associated with an increased mortality were the occurrence of other complications (stroke post-TAVR, acute renal failure, septic shock) and the lack of surgery at index IE hospitalization (padj < 0.05 for all). CONCLUSIONS: PEE occurred in about one-fifth of IE post-TAVR patients, with the presence of coagulase-negative staphylococci and chronic kidney disease determining an increased risk. Patients with PEE-IE exhibited high early and late mortality rates, and surgery during IE hospitalization seemed to be associated with better outcomes.


Subject(s)
Aneurysm, False , Endocarditis, Bacterial , Endocarditis , Renal Insufficiency, Chronic , Transcatheter Aortic Valve Replacement , Abscess , Aneurysm, False/complications , Aneurysm, False/surgery , Coagulase , Endocarditis/epidemiology , Endocarditis/etiology , Endocarditis/surgery , Endocarditis, Bacterial/epidemiology , Endocarditis, Bacterial/etiology , Endocarditis, Bacterial/surgery , Humans , Renal Insufficiency, Chronic/complications , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects
8.
Crit Care Med ; 50(5): 760-769, 2022 05 01.
Article in English | MEDLINE | ID: mdl-34582413

ABSTRACT

OBJECTIVES: Although patients on venoarterial extracorporeal membrane oxygenation for refractory cardiogenic shock are usually supported with mechanical ventilation, it is not clear whether sedation cessation and extubation might improve outcomes. DESIGN: Retrospective cohort study with propensity score overlap weighting analysis. SETTING: Three ICUs in a 1,500-bed tertiary university hospital. PATIENTS: From an overall cohort of 641 patients with venoarterial-extracorporeal membrane oxygenation support, the primary analysis was performed in 344 patients who had been successfully decannulated in order to reduce immortal time bias. MEASUREMENTS AND MAIN RESULTS: Seventy-five patients (22%) were extubated during extracorporeal membrane oxygenation support and were subsequently decannulated alive. Forty-nine percent received noninvasive ventilation, and 25% had emergency reintubation for respiratory, neurologic, or hemodynamic reasons. Higher Simplified Acute Physiology Score II at admission (odds ratio, 0.97; 95% CI [0.95-0.99]; p = 0.008) was associated with a lower probability of extubation, whereas cannulation in cardiac surgery ICU (odds ratio, 3.14; 95% CI [1.21-8.14]; p = 0.018) was associated with an increased probability. Baseline characteristics were well balanced after propensity score overlap weighting. The number of ICU-free days within 30 days of extracorporeal membrane oxygenation decannulation was significantly higher among extubated patients compared with nonextubated patients (22 d [11-26 d] vs 18 d [7-25 d], respectively; p = 0.036). There were no differences in other outcomes including ventilator-associated pneumonia (odds ratio, 0.96; 95% CI [0.51-1.82]; p = 0.90) and all-cause mortality within 30 days of extracorporeal membrane oxygenation decannulation (5% vs 17%; hazard ratio, 0.54; 95% CI [0.19-1.59]; p = 0.27).As a secondary analysis, outcomes were compared in the overall cohort of 641 venoarterial extracorporeal membrane oxygenation-supported patients. Results were consistent with the primary analysis as extubated patients had a higher number of ICU-free days (18 d [0-24 d] vs 0 d [0-18 d], respectively; < 0.001) and a lower risk of death within 30 days of extracorporeal membrane oxygenation cannulation (hazard ratio, 0.45; 95% CI [0.29-0.71]; p = 0.001). CONCLUSIONS: Extubation during venoarterial-extracorporeal membrane oxygenation support is safe, feasible, and associated with greater ICU-free days.


Subject(s)
Cardiac Surgical Procedures , Extracorporeal Membrane Oxygenation , Airway Extubation/adverse effects , Cardiac Surgical Procedures/adverse effects , Extracorporeal Membrane Oxygenation/methods , Humans , Retrospective Studies , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy
9.
J Card Surg ; 37(12): 5019-5026, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36378912

ABSTRACT

BACKGROUND AND AIM: The mortality rate of patients with post-myocardial infarction (MI) ventricular septal defects (VSDs) is high, and the benefit of surgery is unclear. We aimed to investigate the management and outcomes of post-MI VSD over a 10-year period in a large cohort. METHODS: Data of patients with post-MI VSD admitted in three French university hospitals from 2008 to 2019 were examined. The characteristics of those who underwent surgery were compared with those who received medical treatment. Mortality risk factors, survival curves, and outcomes at 30 days and 1 year after treatment were determined. RESULTS: Of the 92 patients whose data were examined, 50 underwent surgery and 42 received exclusive medical treatment. All patients were critically ill. Overall, 76.1% of patients received inotropic support, and 63% received mechanical ventilation. Circulatory assistance, mainly via intra-aortic balloon pump and extra-corporeal membrane oxygenation, was provided to 46.7% patients, with 14.1% requiring a second assistance. The median time to surgery was 4 days. At 1 year, mortality was 46% in those who underwent surgery and 83.3% in those treated medically (p < .001). Survival curves at 1 and 3 months showed major differences, and the survival rate showed little change 30 days after treatment. Cardiogenic shock and cardiac arrest emerged as risk factors for mortality. CONCLUSIONS: In our retrospective, multicenter study, the mortality resulting from post-MI VSD did not seem to improve over the last decade. Although surgery carried considerable risks, it improved survival.


Subject(s)
Heart Septal Defects, Ventricular , Myocardial Infarction , Humans , Retrospective Studies , Myocardial Infarction/complications , Myocardial Infarction/surgery , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy , Heart Septal Defects, Ventricular/etiology , Risk Factors , Treatment Outcome
10.
Circulation ; 141(4): 243-259, 2020 01 28.
Article in English | MEDLINE | ID: mdl-31736356

ABSTRACT

BACKGROUND: No randomized study powered to compare balloon expandable (BE) with self expanding (SE) transcatheter heart valves (THVs) on individual end points after transcatheter aortic valve replacement has been conducted to date. METHODS: From January 2013 to December 2015, the FRANCE-TAVI nationwide registry (Registry of Aortic Valve Bioprostheses Established by Catheter) included 12 141 patients undergoing BE-THV (Edwards, n=8038) or SE-THV (Medtronic, n=4103) for treatment of native aortic stenosis. Long term mortality status was available in all patients (median 20 months; interquartile range, 14 to 30). Patients treated with BE-THV (n=3910) were successfully matched 1:1 with 3910 patients treated with SE-THV by using propensity score (25 clinical, anatomical, and procedural variables) and by date of the procedure (within 3 months). The first coprimary outcome was ≥ moderate occurrence of paravalvular regurgitation or in-hospital mortality, or both. The second coprimary outcome was 2-year all-cause mortality. RESULTS: In propensity-matched analyses, the incidence of the first coprimary outcome was higher with SE-THV (19.8%) compared with BE-THV (11.9%; relative risk, 1.68 [95% CI, 1.46-1.91]; P<0.0001). Each component of the outcome was also higher in patients receiving SE-THV: ≥ moderate paravalvular regurgitation (15.5% versus 8.3%; relative risk, 1.90 [95% CI, 1.63-2.22]; P<0.0001) and in hospital mortality (5.6% versus 4.2%; relative risk, 1.34 [95% CI, 1.07-1.66]; P=0.01). During follow up, all cause mortality occurred in 899 patients treated with SE-THV (2-year mortality, 29.8%) and in 801 patients treated with BE-THV (2-year mortality, 26.6%; hazard ratio, 1.17 [95% CI, 1.06-1.29]; P=0.003). Similar results were found using inverse probability of treatment weighting using propensity score analysis. CONCLUSION: The present study suggests that use of SE-THV was associated with a higher risk of paravalvular regurgitation and higher in-hospital and 2-year mortality compared with use of BE-THV. These data strongly support the need for a randomized trial sufficiently powered to compare the latest generation of SE-THV and BE-THV. CLINICAL TRIAL REGISTRATION: https://www.clinicaltrials.gov. Unique identifier: NCT01777828.


Subject(s)
Heart Valve Prosthesis , Registries , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/surgery , Disease-Free Survival , Female , Follow-Up Studies , France/epidemiology , Humans , Male , Survival Rate
11.
Clin Infect Dis ; 73(11): e3750-e3758, 2021 12 06.
Article in English | MEDLINE | ID: mdl-33733675

ABSTRACT

BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE ( CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.


Subject(s)
Endocarditis, Bacterial , Endocarditis , Transcatheter Aortic Valve Replacement , Endocarditis/epidemiology , Endocarditis/etiology , Endocarditis/surgery , Endocarditis, Bacterial/epidemiology , Endocarditis, Bacterial/etiology , Endocarditis, Bacterial/surgery , Humans , Incidence , Postoperative Complications/epidemiology , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
12.
Europace ; 22(1): 139-148, 2020 01 01.
Article in English | MEDLINE | ID: mdl-31603495

ABSTRACT

AIMS: To identify independent electrocardiogram (ECG) predictors of long-term clinical outcome based on standardized analysis of the surface ECG in a large multicentre cohort of patients with sarcomeric hypertrophic cardiomyopathy (HCM). METHODS AND RESULTS: Retrospective observational study from the REMY French HCM clinical research observatory. Primary endpoint was a composite of all-cause mortality, major non-fatal arrhythmic events, hospitalization for heart failure (HF), and stroke. Secondary endpoints were components of the primary endpoint. Uni- and multivariable Cox proportional hazard regression analysis was performed to identify independent predictors. Among 994 patients with HCM, only 1.8% had a strictly normal baseline ECG. The most prevalent abnormalities were inverted T waves (63.7%), P-wave abnormalities (30.4%), and abnormal Q waves (25.5%). During a mean follow-up of 4.0 ± 2.0 years, a total of 272 major cardiovascular events occurred in 217 patients (21.8%): death or heart transplant in 98 (9.8%), major arrhythmic events in 40 (4.0%), HF hospitalization in 115 (11.6%), and stroke in 23 (2.3%). At multivariable analysis using ECG covariates, prolonged QTc interval, low QRS voltage, and PVCs of right bundle branch block pattern predicted worse outcome, but none remained independently associated with the primary endpoint after adjustment on main demographic and clinical variables. For secondary endpoints, abnormal Q waves independently predicted all-cause death [hazard ratio (HR) 2.35, 95% confidence interval (CI) 1.23-4.47; P = 0.009] and prolonged QTc the risk of HF hospitalization (HR 1.006, 95% CI 1.001-1.011; P = 0.024). CONCLUSION: The 12-lead surface ECG has no independent value to predict the primary outcome measure in patients with HCM. The 12-lead surface ECG has been widely used as a screening tool in HCM but its prognostic value remains poorly known. The value of baseline surface ECG to predict long-term clinical outcomes was studied in a cohort of 994 patients with sarcomeric HCM. The surface ECG has no significant additional value to predict outcome in this patient population.


Subject(s)
Cardiomyopathy, Hypertrophic , Heart Failure , Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/diagnosis , Electrocardiography , Humans , Prognosis , Retrospective Studies , Risk Factors , Sarcomeres
13.
Am Heart J ; 214: 69-76, 2019 08.
Article in English | MEDLINE | ID: mdl-31174053

ABSTRACT

BACKGROUND: Left ventricular assist device (LVAD)-associated infections may be life-threatening and impact patients' outcome. We aimed to identify the characteristics, risk factors, and prognosis of LVAD-associated infections. METHODS: Patients included in the ASSIST-ICD study (19 centers) were enrolled. The main outcome was the occurrence of LVAD-associated infection (driveline infection, pocket infection, or pump/cannula infection) during follow-up. RESULTS: Of the 652 patients enrolled, 201 (30.1%) presented a total of 248 LVAD infections diagnosed 6.5 months after implantation, including 171 (26.2%), 51 (7.8%), and 26 (4.0%) percutaneous driveline infection, pocket infection, or pump/cannula infection, respectively. Patients with infections were aged 58.7 years, and most received HeartMate II (82.1%) or HeartWare (13.4%). Most patients (62%) had implantable cardioverter-defibrillators (ICDs) before LVAD, and 104 (16.0%) had ICD implantation, extraction, or replacement after the LVAD surgery. Main pathogens found among the 248 infections were Staphylococcus aureus (n = 113' 45.4%), Enterobacteriaceae (n = 61; 24.6%), Pseudomonas aeruginosa (n = 34; 13.7%), coagulase-negative staphylococci (n = 13; 5.2%), and Candida species (n = 13; 5.2%). In multivariable analysis, HeartMate II (subhazard ratio, 1.56; 95% CI, 1.03 to 2.36; P = .031) and ICD-related procedures post-LVAD (subhazard ratio, 1.43; 95% CI, 1.03-1.98; P = .031) were significantly associated with LVAD infections. Infections had no detrimental impact on survival. CONCLUSIONS: Left ventricular assist device-associated infections affect one-third of LVAD recipients, mostly related to skin pathogens and gram-negative bacilli, with increased risk with HeartMate II as compared with HeartWare, and in patients who required ICD-related procedures post-LVAD. This is a plea to better select patients needing ICD implantation/replacement after LVAD implantation.


Subject(s)
Catheter-Related Infections/etiology , Heart-Assist Devices/adverse effects , Prosthesis-Related Infections/etiology , Catheter-Related Infections/epidemiology , Catheter-Related Infections/microbiology , Catheter-Related Infections/mortality , Defibrillators, Implantable/statistics & numerical data , Device Removal/statistics & numerical data , Female , France/epidemiology , Heart Ventricles , Heart-Assist Devices/statistics & numerical data , Humans , Male , Middle Aged , Multivariate Analysis , Prognosis , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/microbiology , Prosthesis-Related Infections/mortality , Retrospective Studies , Risk Factors
14.
Echocardiography ; 36(12): 2136-2144, 2019 12.
Article in English | MEDLINE | ID: mdl-31705575

ABSTRACT

BACKGROUND: Treatment strategy for low-gradient (LG) aortic stenosis (AS) remains an unresolved issue. The presence of a low aortic gradient and preserved left ventricular ejection fraction (LVEF) might lead toward the underestimation of aortic stenosis severity and a more conservative management. We sought (a) to describe the nature and timing of intervention according to flow/gradient subgroups in patibents with LG-AS, (2) to determine the factors associated with the decision to intervene, and (c) to describe prognosis. METHODS AND RESULTS: One hundred and ten patients prospectively included in this study underwent a standardized clinical and imaging evaluation at inclusion and at 1-year follow-up. According to aortic flow, gradient and LVEF, patients were divided into 4 groups: LG-normal flow [n = 27], LG-low flow-low LVEF [n = 27], LG-low flow-normal LVEF [n = 16], and high gradient (HG) [n = 40]). 73% of patients underwent AVR 86 ± 59 days after the initial assessment. The HG subgroup had significantly higher intervention rates (P < .001). In multivariable analysis, four parameters were associated with the AVR: aortic gradient (HR 1.52 [1.10-2.11], P = .012), LVEF (HR 0.58 [0.40-0.85], P = .006), atrial fibrillation (HR 0.43 [0.021-0.87], P = .019), and NT-proBNP (HR 0.92[0.86-0.98), P = .008]. Patients operated earlier had better outcomes than those having a delayed AVR (P = .042). LG-AS patients had worse outcomes than HG-AS patients (P < .001). CONCLUSION: Compared to HG-AS, LG-AS is less likely to benefit from an AVR and had a significantly worse outcome. Further interventional studies are needed to investigate the timing of AVR in these patients.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/diagnostic imaging , Disease Management , Echocardiography, Doppler/methods , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Aged , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Female , Follow-Up Studies , Humans , Male , Prognosis , Prospective Studies , Severity of Illness Index , Treatment Outcome
15.
Eur Heart J ; 39(22): 2090-2102, 2018 06 07.
Article in English | MEDLINE | ID: mdl-29554243

ABSTRACT

Aims: To derive and validate a readily useable risk score to identify patients at high-risk of in-hospital ST-segment elevation myocardial infarction (STEMI)-related cardiogenic shock (CS). Methods and results: In all, 6838 patients without CS on admission and treated by primary percutaneous coronary intervention (pPCI), included in the Observatoire Régional Breton sur l'Infarctus (ORBI), served as a derivation cohort, and 2208 patients included in the obseRvatoire des Infarctus de Côte-d'Or (RICO) constituted the external validation cohort. Stepwise multivariable logistic regression was used to build the score. Eleven variables were independently associated with the development of in-hospital CS: age >70 years, prior stroke/transient ischaemic attack, cardiac arrest upon admission, anterior STEMI, first medical contact-to-pPCI delay >90 min, Killip class, heart rate >90/min, a combination of systolic blood pressure <125 mmHg and pulse pressure <45 mmHg, glycaemia >10 mmol/L, culprit lesion of the left main coronary artery, and post-pPCI thrombolysis in myocardial infarction flow grade <3. The score derived from these variables allowed the classification of patients into four risk categories: low (0-7), low-to-intermediate (8-10), intermediate-to-high (11-12), and high (≥13). Observed in-hospital CS rates were 1.3%, 6.6%, 11.7%, and 31.8%, across the four risk categories, respectively. Validation in the RICO cohort demonstrated in-hospital CS rates of 3.1% (score 0-7), 10.6% (score 8-10), 18.1% (score 11-12), and 34.1% (score ≥13). The score demonstrated high discrimination (c-statistic of 0.84 in the derivation cohort, 0.80 in the validation cohort) and adequate calibration in both cohorts. Conclusion: The ORBI risk score provides a readily useable and efficient tool to identify patients at high-risk of developing CS during hospitalization following STEMI, which may aid in further risk-stratification and thus potentially facilitate pre-emptive clinical decision making.


Subject(s)
Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction/surgery , Shock, Cardiogenic/epidemiology , Age Factors , Aged , Aged, 80 and over , Female , France/epidemiology , Heart Arrest/epidemiology , Humans , Hypertension/epidemiology , Logistic Models , Male , Middle Aged , Peripheral Arterial Disease/epidemiology , Prognosis , Registries , Risk Assessment , ST Elevation Myocardial Infarction/epidemiology , Stroke/epidemiology
16.
Minim Invasive Ther Allied Technol ; 28(3): 157-164, 2019 Jun.
Article in English | MEDLINE | ID: mdl-30039720

ABSTRACT

PURPOSE: Minimally invasive trans-catheter aortic valve implantation (TAVI) has emerged as a treatment of choice for high-risk patients with severe aortic stenosis. However, the planning of TAVI procedures would greatly benefit from automation to speed up, secure and guide the deployment of the prosthetic valve. We propose a hybrid approach allowing the computation of relevant anatomical measurements along with an enhanced visualization. MATERIAL AND METHODS: After an initial step of centerline detection and aorta segmentation, model-based and statistical-based methods are used in combination with 3 D active contour models to exploit the complementary aspects of these methods and automatically detect aortic leaflets and coronary ostia locations. Important anatomical measurements are then derived from these landmarks. RESULTS: A validation on 50 patients showed good precision with respect to expert sizing for the ascending aorta diameter calculation (2.2 ± 2.1 mm), the annulus diameter (1.31 ± 0.75 mm), and both the right and left coronary ostia detection (1.96 ± 0.87 mm and 1.80 ± 0.74 mm, respectively). The visualization is enhanced thanks to the aorta and aortic root segmentation, the latter showing good agreement with manual expert delineation (Jaccard index: 0.96 ± 0.03). CONCLUSION: This pipeline is promising and could greatly facilitate TAVI planning.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Aorta/surgery , Automation , Female , Heart Valve Prosthesis , Humans , Male
17.
Circulation ; 136(11): 1049-1069, 2017 Sep 12.
Article in English | MEDLINE | ID: mdl-28893961

ABSTRACT

Transcatheter aortic valve replacement (TAVR) has become a well-accepted option for treating patients with aortic stenosis at intermediate to high or prohibitive surgical risk. TAVR-related conduction disturbances, mainly new-onset left bundle-branch block and advanced atrioventricular block requiring permanent pacemaker implantation, remain the most common complication of this procedure. Furthermore, improvements in TAVR technology, akin to the increasing experience of operators/centers, have translated to a major reduction in periprocedural complications, yet the incidence of conduction disturbances has remained relatively high, with perhaps an increasing trend over time. Several factors have been associated with a heightened risk of conduction disturbances and permanent pacemaker implantation after TAVR, with prior right bundle-branch block and transcatheter valve type and implantation depth being the most commonly reported. New-onset left bundle-branch block and the need for permanent pacemaker implantation may have a significant detrimental association with patients' prognosis. Consequently, strategies intended to reduce the risk and to improve the management of such complications are of paramount importance, particularly in an era when TAVR expansion toward treating lower-risk patients is considered inevitable. In this article, we review the available evidence on the incidence, predictive factors, and clinical association of conduction disturbances after TAVR and propose a strategy for the management of these complications.


Subject(s)
Aortic Valve Stenosis/surgery , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/etiology , Bundle-Branch Block/diagnosis , Bundle-Branch Block/etiology , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/mortality , Arrhythmias, Cardiac/mortality , Bundle-Branch Block/mortality , Forecasting , Humans , Mortality/trends , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/trends , Treatment Outcome
18.
Europace ; 20(7): 1115-1121, 2018 07 01.
Article in English | MEDLINE | ID: mdl-29016748

ABSTRACT

Aims: Pulmonary vein isolation (PVI) using second-generation cryoballoon (CB2) is associated with improved outcomes compared with first generation (CB1). We aimed at investigating the characteristics of left and right PV reconnections after CB1 and CB2 ablations in patients with clinical recurrences requiring redo ablation. Methods and results: From 2010 to 2016, 776 patients underwent 28-mm cryoballoon PVI for symptomatic paroxysmal atrial fibrillation (AF) in 3 centres, 279 with CB1 and 497 with CB2. Among them, 94 patients (12.1%) had symptomatic AF recurrences requiring a redo ablation [43 (15.4%) CB1 and 51 (10.3%) CB2]. The benefit of CB2 over CB1 was compared for each PV. Durable PVI was confirmed in 7 CB1 (16.3%) and 14 CB2 (27.4%) patients, and 2.7 ± 2.1 and 1.4 ± 1.4 gaps per patient were found, respectively (P = 0.002). Significantly more left superior and left inferior PVs were found to be isolated in CB2 compared with CB1 group (78.4% vs. 48.8%, P = 0.005 and 78.4% vs. 46.5%, P = 0.003, respectively) while the rate of durable right superior and right inferior PVs isolation were similar (68.6% vs. 60.5%, P = 0.542 and 66.7% vs. 55.8%, P = 0.387, respectively). Significantly fewer gaps were found in left PVs in CB2 patients, while there was no significant difference for right PVs. Gaps localization was similar in both groups. Conclusion: Fewer reconnection gaps are observed during redo ablations of paroxysmal AF in patients primarily ablated with CB2. This difference is driven by less reconnection gaps observed in both left PVs, while no difference was observed for right PVs.


Subject(s)
Atrial Fibrillation/surgery , Cardiac Catheters , Catheter Ablation/instrumentation , Cryosurgery/instrumentation , Pulmonary Veins/surgery , Action Potentials , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Catheter Ablation/adverse effects , Cryosurgery/adverse effects , Equipment Design , Female , France , Heart Rate , Humans , Male , Middle Aged , Pulmonary Veins/physiopathology , Recurrence , Retrospective Studies , Time Factors , Treatment Outcome
19.
Crit Care Med ; 50(6): e607-e608, 2022 Jun 01.
Article in English | MEDLINE | ID: mdl-35612456
20.
Crit Care Med ; 45(3): e281-e289, 2017 03.
Article in English | MEDLINE | ID: mdl-27755013

ABSTRACT

OBJECTIVES: Extracorporeal life support is used for patients with severe heart failure as a bridge to heart transplantation or recovery. We aimed at analyzing the efficacy and safety of extracorporeal life support to treat refractory arrhythmic storm responsible for cardiogenic shock in patients resistant to antiarrhythmic drugs. DESIGN: Retrospective study. SETTING: University Hospital of Rennes, France. PATIENTS: Patients with refractory arrhythmic storm admitted between January 2005 and March 2015. INTERVENTIONS: Patients with intractable refractory arrhythmic storm and cardiogenic shock despite optimal medical therapy were implanted with an extracorporeal life support. Patients' characteristics and outcomes after extracorporeal life support implantation were analyzed. MEASUREMENTS AND MAIN RESULTS: Twenty-six patients (23 men, 52.4 ± 9.2 yr old) were included, most of them having ischemic cardiomyopathy (65.4%). Stable sinus rhythm restoration was immediate in 61.5% of patients and occurred after a median time of 3 hours after extracorporeal life support implantation for the remaining ones. Thirteen patients (50%) eventually died, none of them due to extracorporeal life support-related complications, but mostly due to the occurrence of multiple organ failure, and occurred after a median time of 4 days. The remaining 13 patients (50%) had extracorporeal life support withdrawn after 6.7 ± 3.6 days and were discharged after 34.7 ± 14.7 days after admission. Patients with repetitive ventricular tachycardia/ventricular fibrillation episodes alternating with periods of sinus rhythm at the time of implantation had a better survival than those in refractory ventricular fibrillation (p = 0.017). CONCLUSIONS: This is the largest database of patients temporary implanted with extracorporeal life support for refractory arrhythmic storm responsible for cardiogenic shock resistant to antiarrhythmic drugs. It provides efficient hemodynamic support and survival rate after the implantation is 50%.


Subject(s)
Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/therapy , Extracorporeal Membrane Oxygenation , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy , Adult , Anti-Arrhythmia Agents , Arrhythmias, Cardiac/physiopathology , Drug Resistance , Female , Humans , Male , Middle Aged , Retrospective Studies , Shock, Cardiogenic/physiopathology , Survival Rate , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL