Int J Radiat Oncol Biol Phys ; 38(5): 1113-21, 1997 Jul 15.
Article in English | MEDLINE | ID: mdl-9276379

ABSTRACT

PURPOSE: The patient population treated with fractionated stereotactic radiotherapy (SRT) is significantly different than that treated with stereotactic radiosurgery (SRS). Generally, lesions treated with SRT are larger, less spherical, and located within critical regions of the central nervous system; hence, they offer new challenges to the treatment planner. Here a simple, cost effective, beam shaping system has been evaluated relative to both circular collimators and an ideal dynamically conforming system for effectiveness in providing conformal therapy for these lesions. METHODS AND MATERIALS: We have modeled a simple system for conformal arc therapy using four independent jaws. The jaw positions and collimator angle are changed between arcs but held fixed for the duration of each arc. Eleven previously treated SRT cases have been replanned using this system. The rectangular jaw plans were then compared to the original treatment plans which used circular collimators. The plans were evaluated with respect to tissue sparing at 100%, 80%, 50%, and 20% of the prescription dose. A plan was also done for each tumor in which the beam aperture was continuously conformed to the beams eye view projection of the tumor. This was used as an ideal standard for conformal therapy in the absence of fluence modulation. RESULTS: For tumors with a maximum extent of over 3.5 cm the rectangular jaw plans reduced the mean volume of healthy tissue involved at the prescription dose by 57% relative to the circular collimator plans. The ideal conformal plans offered no significant further improvement at the prescription dose. The relative advantage of the rectangular jaw plans decreased at lower isodoses so that at 20% of the prescription dose tissue involvement for the rectangular jaw plans was equivalent to that for the circular collimator plans. At these isodoses the ideal conformal plans gave substantially better tissue sparing. CONCLUSION: A simple and economical field shaping device has been shown to provide all of the beam shaping advantage of a hypothetical ideal dynamically conforming system at the prescription level. This system may be immediately implemented in the clinic. It offers a substantial advantage over the currently used circular collimators in the high dose region with equivalent performance in the low dose region.


Subject(s)
Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , Humans , Radiosurgery/instrumentation , Radiotherapy Planning, Computer-Assisted/instrumentation
2.
Med Phys ; 25(8): 1438-42, 1998 Aug.
Article in English | MEDLINE | ID: mdl-9725131

ABSTRACT

The proximity of the lens to the retina makes the treatment of retinoblastoma a challenge for external beam radiation therapy. The approximately 1 mm separation between the posterior edge of the lens and the anterior region of the retina causes a trade-off between coverage of the entire retina and excessive dose to the lens. A stereotactic, LINAC based, lens sparing technique for treating retinoblastoma is presented. The technique uses noncoplanar arcs with the lens at isocenter. A special noncircular collimator blocks the lens but it also causes the dose distribution to vary across the retina. A fluence modulation filter is used to reduce the dose inhomogeneity across the target. The resulting dose distribution is roughly hemispheric, providing both anterior coverage of the retina and lens blocking unlike conventional techniques. The method used to develop the collimator and filter assembly is presented. Dosimetry of the assembly was carried out using radiochromic film, and the results were entered in a treatment planning system. The dose distribution as measured in a phantom is provided and compared to calculations.


Subject(s)
Eye Neoplasms/radiotherapy , Radiotherapy/instrumentation , Retinoblastoma/radiotherapy , Equipment Design , Humans , Lens, Crystalline , Phantoms, Imaging , Radiation Protection , Radiotherapy/methods , Radiotherapy Dosage , Retina
3.
Med Dosim ; 23(3): 187-99, 1998.
Article in English | MEDLINE | ID: mdl-9783272

ABSTRACT

The Joint Center for Radiation Therapy (JCRT) has treated intra-cranial lesions with high-dose single fraction stereotactic radiosurgery (SRS) since 1986 and with multi-fraction stereotactic radiotherapy (SRT) since 1992. This paper describes the JCRT techniques for treatment planning and delivery for SRS, and to a limited extent for SRT. LINAC quality assurance, treatment delivery, and patient management for stereotactic radiosurgery and stereotactic radiotherapy technique are closely related at the JCRT, although differences exist. An historical retrospective of our experience with stereotactic techniques including imaging modalities, treatment planning techniques, optimization methods, and treatment delivery is presented. Three treatment planning approaches, single isocenter, multiple isocenter, and micro-jaw field shaping are used to demonstrate the capabilities and technical dosimetric features of each approach. The major planning differences and clinical of each technique are described. From our experience, lesions less than 3.0 cm in maximum extent are well treated with circular fields using either a single or multiple isocenter configuration. Lesions greater than 3.0 cm in maximum extent usually benefit from field shaping using the micro-jaws. For these large lesions, the shaped field approach typically improves the dose homogeneity as well as reduces the amount of healthy brain irradiated. Our physicians choose between the three techniques to meet the desired clinical outcome the patient's situation requires.


Subject(s)
Radiosurgery , Boston , Brain Neoplasms/surgery , Cerebral Angiography , Humans , Magnetic Resonance Imaging , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted , Retrospective Studies , Stereotaxic Techniques , Tomography, X-Ray Computed
4.
JAMA ; 264(5): 619-21, 1990 Aug 01.
Article in English | MEDLINE | ID: mdl-2366303

ABSTRACT

Radithor was a radioactive patent medicine that was touted as a metabolic stimulant and aphrodisiac. We have obtained several original samples of Radithor and have used these historical specimens and a computer-based calculation model to perform a retrospective analysis of a famous case of Radithor-related radium poisoning. Our data suggest that the victim's cumulative skeletal radiation dose may have exceeded 350 Sv by the time he died. This figure far exceeds most current estimates of what radiation exposure level would constitute a rapidly lethal dose if given acutely. The physiological response to longterm internal radiation exposure and the highly localized nature of alpha particle irradiation may require the development of new models for the assessment of risk in cases of internal alpha particle irradiation.


Subject(s)
Nonprescription Drugs/poisoning , Radium/poisoning , Bone and Bones/analysis , Bone and Bones/radiation effects , Humans , Iatrogenic Disease , Nonprescription Drugs/analysis , Radiation Dosage , Radiometry , Radium/analysis , Spectrum Analysis