Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters

Database
Language
Publication year range
1.
Environ Health Perspect ; 102 Suppl 6: 23-5, 1994 Oct.
Article in English | MEDLINE | ID: mdl-7889853

ABSTRACT

In two studies, involving 75 and 72 workers, potential exposure to 3-chloro-4-fluoroaniline (CFA) was biologically monitored by determination of its main urinary metabolite 2-amino-4-chloro-5-fluorophenol sulfate (CFA-S). As this method only allows the detection of recent exposure, analysis of CFA adducts bound to hemoglobin (Hb) was investigated as a method that allows biological monitoring of exposure to CFA over longer periods. The median CFA-S concentration in 67 samples from the first study was 0.14 mumole/g creatinine (range < 0.05-2.82) and in 201 samples from the second study 0.21 mumole/g creatinine (range < 0.05-6.05). In addition, urine samples, collected after shifts with supposed incidental exposure, slightly higher concentrations were measured: 0.27 mumole/g creatinine (range < 0.05-122; 18 samples) and 0.76 mumole/g creatinine (range < 0.05-18.5; 46 samples), respectively. The median Hb adduct concentration in 75 samples from the first study was 9 pmoles CFA/g Hb (range < 5-640) and in 46 samples from the second study 12 pmoles/g Hb (range 3-24). In 24 blood samples collected after incidents, a median concentration of 13 pmoles CFA/g Hb (range < 5-52) was found. Urinary CFA-S and Hb adducts correlated well in samples collected shortly after incidental exposures. However, in 25% of the operators, no CFA-S was detected during routine biological monitoring while Hb adduct analysis showed clear evidence of exposure. This indicates that because of the stability of Hb adducts of CFA in blood, intermittent exposure to CFA is more reliably biologically monitored by determination of Hb adducts of CFA than by assessment of urinary CFA-S.


Subject(s)
Aniline Compounds/metabolism , Chemical Industry , Hemoglobins/metabolism , Occupational Exposure , Aniline Compounds/chemistry , Humans , Molecular Structure , Monitoring, Physiologic
2.
Environ Health Perspect ; 99: 217-20, 1993 Mar.
Article in English | MEDLINE | ID: mdl-8319627

ABSTRACT

In a study on workers in a chemical plant where ethylene oxide (EtO) is manufactured and partly used for ethylene glycol production, exposure to EtO was monitored during annual periodic health assessments in January 1988, December 1988, and March 1990 by the determination of the level of 2-hydroxyethylvaline (HOEtVal) in hemoglobin. The HOEtVal levels in workers corresponded with the potential EtO exposures. The highest level was found in December 1988, in blood samples collected 1-2 months after a shut-down, maintenance, and start-up program. The range of adduct levels found in the three examinations indicated that average EtO exposures during the 4 months preceding blood sampling were below 0.5 ppm. It was demonstrated that the method allows for the accurate monitoring of low levels of EtO exposure and provides personalized time-integrated exposure data with great discriminative power. In addition, the method may serve to identify unexpected personal exposures, which may lead to targeted exposure control measures.


Subject(s)
Ethylene Oxide/adverse effects , Hemoglobins/drug effects , Occupational Exposure , Chemical Industry , Environmental Monitoring , Ethylene Oxide/administration & dosage , Ethylene Oxide/blood , Hemoglobins/metabolism , Humans , Valine/analogs & derivatives , Valine/blood
3.
Environ Health Perspect ; 102 Suppl 6: 27-9, 1994 Oct.
Article in English | MEDLINE | ID: mdl-7889854

ABSTRACT

Exposure to 2,4-difluoroaniline (DFA) was monitored by GC-MS of DFA adducts bound to hemoglobin (Hb). In two studies, involving 20 and 16 workers potentially exposed to low concentrations of DFA, median concentrations of 10 (range 1-83) and 20 (range 4-322) pmole/g Hb were found, respectively. For better interpretation of these results, the in vivo binding of DFA to Hb was investigated. DFA was administered orally at doses of 0, 0.078, 0.775, 7.75, and 77.5 mumole/kg/day, to 10 male and 10 female Fischer 344 rats for 10 consecutive days (2 rats/sex/dose group). A linear relation between dose and adduct concentration was observed. At the two lowest doses (0.078 and 0.775 mumole/kg/day) no methemoglobinemia was observed, but adducts could easily be measured. At these doses, the mean adduct levels were in the same range as found in the human studies. As yet, no occupational exposure limit for DFA has been established. The German biological tolerance value (BAT-value) for aniline was set at 7.2 nmole/g Hb. This BAT-value is based on the relation between methemoglobinemia and adduct formation. The amount of Hb binding by aniline and DFA was found to be similar in the rat. Assuming that this is also the case in humans, the BAT-value for aniline may tentatively be used for DFA as well. In both studies of occupationally exposed workers, the adduct levels were well below this BAT-value.


Subject(s)
Aniline Compounds/analysis , Hemoglobins/metabolism , Animals , Female , Humans , Linear Models , Male , Occupational Exposure , Rats , Rats, Inbred F344
4.
Br J Ind Med ; 50(5): 460-9, 1993 May.
Article in English | MEDLINE | ID: mdl-8507599

ABSTRACT

Recently, the determination of S-phenylmercapturic acid (S-PMA) in urine has been proposed as a suitable biomarker for the monitoring of low level exposures to benzene. In the study reported here, the test has been validated in 12 separate studies in chemical manufacturing plants, oil refineries, and natural gas production plants. Parameters studied were the urinary excretion characteristics of S-PMA, the specificity and the sensitivity of the assay, and the relations between exposures to airborne benzene and urinary S-PMA concentrations and between urinary phenol and S-PMA concentrations. The range of exposures to benzene was highest in workers in chemical manufacturing plants and in workers cleaning tanks or installations containing benzene as a component of natural gas condensate. Urinary S-PMA concentrations were measured up to 543 micrograms/g creatinine. Workers' exposures to benzene were lowest in oil refineries and S-PMA concentrations were comparable with those in smoking or nonsmoking control persons (most below the detection limit of 1 to 5 micrograms/g creatinine). In most workers S-PMA was excreted in a single phase and the highest S-PMA concentrations were at the end of an eight hour shift. The average half life of elimination was 9.0 (SD 4.5) hours (31 workers). Tentatively, in five workers a second phase of elimination was found with an average half life of 45 (SD 4) hours. A strong correlation was found between eight hour exposure to airborne benzene of 1 mg/m3 (0.3 ppm) and higher and urinary S-PMA concentrations in end of shift samples. It was calculated that an eight hour benzene exposure of 3.25 mg/m3 (1 ppm) corresponds to an average S-PMA concentration of 46 micrograms/g creatinine (95% confidence interval 41-50 micrograms/g creatinine). A strong correlation was also found between urinary phenol and S-PMA concentrations. At a urinary phenol concentration of 50 mg/g creatinine, corresponding to an eight hour benzene exposure of 32.5 mg/m3 (10 ppm), the average urinary S-PMA concentration was 383 micrograms/g creatinine. In conclusion, with the current sensitivity of the test, eight hour time weighted average benzene exposures of 1 mg/m3 (0.3 ppm) and higher can be measured.


Subject(s)
Acetylcysteine/analogs & derivatives , Benzene/analysis , Occupational Exposure , Acetylcysteine/urine , Air/analysis , Biomarkers/urine , Chemical Industry , Creatinine/urine , Humans , Sensitivity and Specificity , Time Factors
5.
Anal Biochem ; 203(2): 357-60, 1992 Jun.
Article in English | MEDLINE | ID: mdl-1416033

ABSTRACT

Hemoglobin adducts are useful for the identification and quantification of electrophilic agents in vivo. A modified Edman degradation method has been extensively used for monitoring exposure to ethylene oxide through gas chromatographic-mass spectrometric measurements of hydroxyethyl adducts to the N-terminal valines in hemoglobin. In a ring test, four laboratories using different versions of the method analyzed eight human globin samples with low adduct levels from ethylene oxide. Measurements of the same adduct by a radioimmunoassay were also included. Strong correlation between the measurements by the different laboratories shows that the method in principle works well. However, there were some systematic quantitative differences.


Subject(s)
Hemoglobins/chemistry , Valine/analogs & derivatives , Humans , Radioimmunoassay , Regression Analysis , Valine/analysis
SELECTION OF CITATIONS
SEARCH DETAIL