ABSTRACT
In this work, laser ablation (LA) was characterized as a method for sampling and introducing microplastic particles (MPs) into an inductively coupled plasma (ICP) for subsequent 13C+ monitoring using an ICP-mass spectrometer operated in single-event mode. MPs of different types (PS, PMMA, and PVC) and sizes (2-20 µm) were introduced intactly. The laser energy density did not affect the particle sampling across a wide range (0.25-6.00 J cm-2). Single-shot analysis separated clustered MPs (2-7 MPs per cluster) during the LA and particle transport processes, allowing the temporally resolved analysis of the individual constituting MPs. Line scanning showed superior performance when using a small laser beam diameter combined with a high repetition rate. The 13C+ signal intensity correlated linearly (R2 >0.9945) with the absolute C mass in a 2-10 µm size range, while the use of He in the collision-reaction cell (CRC) allowed extension of the linear range to 20 µm. The LA approach generated narrower 13C+ signal distributions than the traditional solution-based approach (dry versus wet plasma conditions) and proved successful for the analysis of a mixed suspension (containing four sizes of PS MPs in a 2-5 µm size range) and for sampling MPs from PVDF and glass microfiber filters, with the latter offering a lower background.
ABSTRACT
Hypomagnesemia was historically prevalent in individuals with type 1 diabetes mellitus (T1DM), but contemporary results indicate an incidence comparable to that in the general population, likely due to improved treatment in recent decades, resulting in better glycemic control. However, a recent study found a significant difference between the serum Mg isotopic composition of T1DM individuals and controls, indicating that disruptions to Mg homeostasis persist. Significant deviations were also found in samples taken one year apart. To investigate whether the temporal variability in serum Mg isotopic composition is linked to the transient impact of administered insulin, Mg isotope ratios were determined in serum from 15 T1DM individuals before and one hour after insulin injection/meal consumption using multi-collector inductively coupled plasma-mass spectrometry. Consistent with results of the previous study, significant difference in the serum Mg isotopic composition was found between T1DM individuals and 10 sex-matched controls. However, the average difference between pre- and post-insulin injection/meal T1DM samples of 0.05 ± 0.13‱ (1SD) was not significant. No difference was observed for controls before (-0.12 ± 0.16‱) and after the meal (-0.10 ± 0.13‱) either, suggesting a lack of a postprandial Mg isotopic response within one hour of food consumption, and that the timing of the most recent meal may not require controlling for when determining serum Mg isotopic composition.
Subject(s)
Diabetes Mellitus, Type 1 , Humans , Isotopes , Magnesium , Insulin , Insulin, Regular, HumanABSTRACT
Biogenic palladium nanoparticles (bio-Pd NPs) are used for the reductive transformation and/or dehalogenation of persistent micropollutants. In this work, H2 (electron donor) was produced in situ by an electrochemical cell, permitting steered production of differently sized bio-Pd NPs. The catalytic activity was first assessed by the degradation of methyl orange. The NPs showing the highest catalytic activity were selected for the removal of micropollutants from secondary treated municipal wastewater. The synthesis at different H2 flow rates (0.310 L/hr or 0.646 L/hr) influenced the bio-Pd NPs size. The NPs produced over 6 hr at a low H2 flow rate had a larger size (D50 = 39.0 nm) than those produced in 3 hr at a high H2 flow rate (D50 = 23.2 nm). Removal of 92.1% and 44.3% of methyl orange was obtained after 30 min for the NPs with sizes of 39.0 nm and 23.2 nm, respectively. Bio-Pd NPs of 39.0 nm were used to treat micropollutants present in secondary treated municipal wastewater at concentrations ranging from µg/L to ng/L. Effective removal of 8 compounds was observed: ibuprofen (69.5%) < sulfamethoxazole (80.6%) < naproxen (81.4%) < furosemide (89.7%) < citalopram (91.7%) < diclofenac (91.9%) < atorvastatin (> 94.3%) < lorazepam (97.2%). Removal of fluorinated antibiotics occurred at > 90% efficiency. Overall, these data indicate that the size, and thus the catalytic activity of the NPs can be steered and that the removal of challenging micropollutants at environmentally relevant concentrations can be achieved through the use of bio-Pd NPs.
Subject(s)
Metal Nanoparticles , Water Pollutants, Chemical , Water Purification , Wastewater , Palladium/chemistry , Water Pollutants, Chemical/metabolismABSTRACT
Nanoparticle (NP) delivery to solid tumors remains an actively studied field, where several recent studies have shed new insights into the underlying mechanisms and the still overall poor efficacy. In the present study, Au NPs of different sizes were used as model systems to address this topic, where delivery of the systemically administered NPs to the tumor as a whole or to tumor cells specifically was examined in view of a broad range of tumor-associated parameters. Using non-invasive imaging combined with histology, immunohistochemistry, single-cell spatial RNA expression and image-based single cell cytometry revealed a size-dependent complex interaction of multiple parameters that promoted tumor and tumor-cell specific NP delivery. Interestingly, the data show that most NPs are sequestered by tumor-associated macrophages and cancer-associated fibroblasts, while only few NPs reach the actual tumor cells. While perfusion is important, leaky blood vessels were found not to promote NP delivery, but rather that delivery efficacy correlated with the maturity level of tumor-associated blood vessels. In line with recent studies, we found that the presence of specialized endothelial cells, expressing high levels of CD276 and Plvap promoted both tumor delivery and tumor cell-specific delivery of NPs. This study identifies several parameters that can be used to determine the suitability of NP delivery to the tumor region or to tumor cells specifically, and enables personalized approaches for maximal delivery of nanoformulations to the targeted tumor.
Subject(s)
Metal Nanoparticles , Nanoparticles , Neoplasms , Humans , Tumor Microenvironment , Particle Size , Gold/metabolism , Endothelial Cells/metabolism , Neoplasms/metabolism , Drug Delivery Systems/methods , Cell Line, Tumor , B7 Antigens/metabolismABSTRACT
Liver and muscle tissue of tusks ( Brosme brosme) have been analyzed for their THg and MeHg concentrations and Hg isotopic signatures for tracing Hg pollution along the Norwegian coast. Clear differences between tissue types and locations were established. At five of the eight locations, the Hg concentration in muscle exceeded the maximum allowable level of 0.5 mg kg-1 wet weight. δ202Hg values in both tissue types indicated that Hg speciation affects the bulk Hg isotopic signature. Tusk liver seems to be more sensitive to immediate changes and to anthropogenic inorganic Hg, while the muscle rather reflects the Hg accumulated over a longer period of exposure. The δ202Hg values of liver and muscle also enabled different sources of Hg and exposure pathways to be distinguished. δ202Hgmuscle-δ202Hgliver showed a clear correlation with the % MeHg in tusk liver for the coastal waters, but not for the fjords. The absence of significant differences in Δ199Hg values between both tissues of tusk from the same location suggests that in vivo metabolic processes are the underlying reason for the differences in Hg speciation and in δ202Hg values. This work highlights the importance of selecting different tissues of marine fish in future Hg monitoring programs.
Subject(s)
Mercury , Methylmercury Compounds , Water Pollutants, Chemical , Animals , Environmental Monitoring , Fishes , Liver , Norway , WaterABSTRACT
Hg pollution released from the U-864 submarine sunk during WWII and potential introduction of that Hg into the marine food chain have been studied by a combination of quantitative Hg and MeHg determination and Hg isotopic analysis via cold vapor generation multicollector inductively coupled plasma-mass spectrometry (CVG-MC-ICP-MS) in sediment and Cancer pagurus samples. The sediment pollution could be unequivocally linked with the metallic Hg present in the wreck. Crabs were collected at the wreck location and 4 nmi north and south, and their brown and claw meat were analyzed separately. For brown meat, the δ202Hg values of the individuals from the wreck location were shifted toward the isotopic signature of the sediment and, thus, the submarine Hg. Such differences were not found for claw meat. The isotope ratio results suggest direct ingestion of metallic Hg by C. pagurus but do not offer any proof for any other introduction of the submarine Hg into the marine food chain.
Subject(s)
Brachyura , Mercury , Animals , Environmental Pollution , Gases , Isotopes/chemistryABSTRACT
Mercury (Hg) isotopic analysis via multi-collector inductively coupled plasma (ICP)-mass spectrometry (MC-ICP-MS) can provide relevant biogeochemical information by revealing sources, pathways, and sinks of this highly toxic metal. In this work, the capabilities and limitations of two different sample introduction systems, based on pneumatic nebulization (PN) and cold vapor generation (CVG), respectively, were evaluated in the context of Hg isotopic analysis via MC-ICP-MS. The effect of (i) instrument settings and acquisition parameters, (ii) concentration of analyte element (Hg), and internal standard (Tl)-used for mass discrimination correction purposes-and (iii) different mass bias correction approaches on the accuracy and precision of Hg isotope ratio results was evaluated. The extent and stability of mass bias were assessed in a long-term study (18 months, n = 250), demonstrating a precision ≤0.006% relative standard deviation (RSD). CVG-MC-ICP-MS showed an approximately 20-fold enhancement in Hg signal intensity compared with PN-MC-ICP-MS. For CVG-MC-ICP-MS, the mass bias induced by instrumental mass discrimination was accurately corrected for by using either external correction in a sample-standard bracketing approach (SSB) or double correction, consisting of the use of Tl as internal standard in a revised version of the Russell law (Baxter approach), followed by SSB. Concomitant matrix elements did not affect CVG-ICP-MS results. Neither with PN, nor with CVG, any evidence for mass-independent discrimination effects in the instrument was observed within the experimental precision obtained. CVG-MC-ICP-MS was finally used for Hg isotopic analysis of reference materials (RMs) of relevant environmental origin. The isotopic composition of Hg in RMs of marine biological origin testified of mass-independent fractionation that affected the odd-numbered Hg isotopes. While older RMs were used for validation purposes, novel Hg isotopic data are provided for the latest generations of some biological RMs.
Subject(s)
Isotopes/chemistry , Mass Spectrometry/methods , Mercury/chemistry , Gases/chemistry , VolatilizationABSTRACT
Interference-free conditions, allowing straightforward As and Se determination, can be obtained by using CH3F (a mixture of 10% CH3F and 90% He) as a reaction gas in tandem ICP-mass spectrometry (ICP-MS/MS). Both target elements react via CH3F addition and subsequent HF elimination, rendering AsCH2 (+) and SeCH2 (+) the respective favored reaction product ions. Instrumental limits of detection were 0.2 ng L(-1) for As and below 10 ng L(-1) for Se, using either (77)Se, (78)Se, or (80)Se. Neither addition of carbon to the solutions, nor admixing of additional He into the octopole reaction cell resulted in a further improvement of the LoDs, despite the increase in analyte signal intensity. By using synthetic matrices, containing elements giving rise to ions interfering at either the original mass-to-charge ratios or those of the reaction products, absence of spectral overlap could be demonstrated. This conclusion was corroborated by successful As and Se determination in a collection of reference materials from plant, animal, or environmental origin, displaying a considerable range of As and Se contents. These accurate results were obtained via external calibration using Te as an internal standard. The high efficiency reaction between As and CH3F and the possibility to use the major isotope of Se provides enhanced detection power versus other techniques, such as sector-field ICP-mass spectrometry, while the possibility to monitor at least three Se isotopes interference-free also enables isotopic analysis.
ABSTRACT
Methyl fluoride (a mixture of 10% CH3F and 90% of He) was evaluated as a reaction gas in inductively coupled plasma-tandem mass spectrometry (ICPMS/MS) in the context of the determination of ultratrace concentrations of medically relevant metals (Al, Co, Cr, Mn, Ni, Ti, and V) in blood serum and urine. Via product ion scanning, whereby only ions of the mass-to-charge ratio of the target nuclide were admitted into the octopole reaction cell, the various reaction product ions formed for each of the target elements were identified at different CH3F gas flow rates. Limits of detection (LODs) and of quantification (LOQs) and linearity of the calibration curve were documented under (i) optimized ICPMS/MS conditions for single-element monitoring and (ii) compromise conditions, allowing for multielement determination. Even under compromise settings, instrumental LODs were below 10 ng/L for all target elements, while the use of CH3F provided interference-free conditions for their determination in the biofluids of interest. Quantitative data obtained for Seronorm blood serum and urine reference materials were in excellent agreement with the corresponding reference values and/or results obtained using double-focusing sector-field ICPMS (for those elements for which no certified values were available or that were affected during reconstitution), proving the potential of this reaction gas for multielement ultratrace analysis via ICPMS/MS.
Subject(s)
Body Fluids/chemistry , Hydrocarbons, Fluorinated/chemistry , Metals/analysis , Tandem Mass Spectrometry/methods , Limit of DetectionABSTRACT
High-precision isotopic analysis of mercury (Hg) using multi-collector ICP-mass spectrometry (MC-ICP-MS) is a powerful method for obtaining insight into the sources, pathways and sinks of this toxic metal. Modification of a commercially available mercury analyzer (Teledyne Leeman Labs, Hydra IIc - originally designed for quantification of Hg through sample combustion, collection of the Hg vapor on a gold amalgamator, subsequent controlled release of Hg and detection using cold vapor atomic absorption spectrometry CVAAS) enabled the system to be used for the direct high-precision Hg isotopic analysis of solid samples using MC-ICP-MS - i.e., without previous sample digestion and subsequent dilution. The changes made to the mercury analyzer did not compromise its (simultaneous) use for Hg quantification via CVAAS. The Hg vapor was mixed with a Tl-containing aerosol produced via pneumatic nebulization, creating wet plasma conditions, and enabling the use of Tl as an internal standard for correction of instrumental mass discrimination. Accurate and precise (0.10 2SD, δ202Hg, n = 5) results were obtained for an in-house standard solution of Hg (20 ng Hg sample intake). Initial validation relied on the successful analysis of two solid certified reference materials of biological origin (BCR CRM 464 Tuna fish and NRC-CNRC TORT-3 Lobster hepatopancreas). It was shown that instrumental mass discrimination can be adequately corrected for by relying on the use of an aqueous Hg standard solution (NIST SRM 3133), without the need of matrix-matching. The novel setup developed thus allows for direct high-precision isotopic analysis of Hg in solid samples, thus enhancing the sample throughput. It is also suited for samples for which low amounts are available only and/or that are characterized by low Hg concentrations.
ABSTRACT
Numerous factors can contribute to the incidence or exacerbation of peripheral neuropathy induced by oxaliplatin (OXA). Recently, platinum accumulation in the spinal cord of mice after OXA exposure, despite the efficient defenses of the central nervous system, has been demonstrated by our research group, expanding the knowledge about its toxicity. One hypothesis is platinum accumulation in the spinal cord causes oxidative damage to neurons and impairs mitochondrial function. Thus, the main aim of this study was to investigate the relationship between aging and OXA-induced neuropathic pain and its comorbidities, including anxious behavior and cognitive impairment. By using an OXA-induced peripheral neuropathy model, platinum and bioelement concentrations and their influence on oxidative damage, neuroprotection, and neuroplasticity pathways were evaluated in Swiss mice, and our findings showed that treatment with OXA exacerbated pain and anxious behavior, albeit not age-induced cognitive impairment. Platinum deposition in the spinal cord and, for the first time, in the brain of mice exposed to OXA, regardless of age, was identified. We found that alterations in bioelement concentration, oxidative damage, neuroprotection, and neuroplasticity pathways induced by aging contribute to OXA-induced peripheral neuropathy. Our results strive to supply a basis for therapeutic interventions for OXA-induced peripheral neuropathy considering age specificities.
ABSTRACT
Agronomic biofortification using selenium nanoparticles (SeNPs) shows potential for addressing selenium deficiency but further research on SeNPs-plants interaction is required before it can be effectively used to improve nutritional quality. In this work, single-particle inductively coupled plasma-mass spectrometry (SP-ICP-MS) was used for tracing isotopically labeled SeNPs (82SeNPs) in Oryza sativa L. tissues. For this purpose, SeNPs with natural isotopic abundance and 82SeNPs were synthesized by a chemical method. The NPs characterization by transmission electron microscopy (TEM) confirmed that enriched NPs maintained the basic properties of unlabeled NPs, showing spherical shape, monodispersity, and sizes in the nano-range (82.8 ± 6.6 nm and 73.2 ± 4.4 nm for SeNPs and 82SeNPs, respectively). The use of 82SeNPs resulted in an 11-fold enhancement in the detection power for ICP-MS analysis, accompanied by an improvement in the signal-to-background ratio and a reduction of the size limits of detection from 89.9 to 39.9 nm in SP-ICP-MS analysis. This enabled 82SeNPs to be tracked in O. sativa L. plants cultivated under foliar application of 82SeNPs. Tracing studies combining SP-ICP-MS and TEM-energy-dispersive X-ray spectroscopy data confirmed the uptake of intact 82SeNPs by rice leaves, with most NPs remaining in the leaves and very few particles translocated to shoots and roots. Translocation of Se from leaves to roots and shoots was found to be lower when applied as NPs compared to selenite application. From the size distributions, as obtained by SP-ICP-MS, it can be concluded that a fraction of the 82SeNPs remained within the same size range as that of the applied NP suspension, while other fraction underwent an agglomeration process in the leaves, as confirmed by TEM images. This illustrates the potential of SP-ICP-MS analysis of isotopically enriched 82SeNPs for tracing NPs in the presence of background elements within complex plant matrices, providing important information about the uptake, accumulation, and biotransformation of SeNPs in rice plants.
Subject(s)
Mass Spectrometry , Nanoparticles , Oryza , Selenium , Selenium/chemistry , Selenium/analysis , Oryza/chemistry , Oryza/metabolism , Mass Spectrometry/methods , Nanoparticles/chemistry , Isotope Labeling , Plant Leaves/chemistry , Plant Leaves/metabolism , Metal Nanoparticles/chemistry , Particle SizeABSTRACT
The ability to improve nanoparticle delivery to solid tumors is an actively studied domain, where various mechanisms are looked into. In previous work, the authors have looked into nanoparticle size, tumor vessel normalization, and disintegration, and here it is aimed to continue this work by performing an in-depth mechanistic study on the use of ciRGD peptide co-administration. Using a multiparametric approach, it is observed that ciRGD can improve nanoparticle delivery to the tumor itself, but also to tumor cells specifically better than vessel normalization strategies. The effect depends on the level of tumor perfusion, hypoxia, neutrophil levels, and vessel permeability. This work shows that upon characterizing tumors for these parameters, conditions can be selected that can optimally benefit from ciRGD co-administration as a means to improve NP delivery to solid tumors.
Subject(s)
Nanoparticles , Neoplasms , Humans , Neuropilin-1/therapeutic use , Neutrophils , Drug Delivery Systems , Neoplasms/drug therapy , Neoplasms/pathology , Nanoparticles/chemistry , HypoxiaABSTRACT
The production of biogenic palladium nanoparticles (bio-Pd NPs) is widely studied due to their high catalytic activity, which depends on the size of nanoparticles (NPs). Smaller NPs (here defined as <100 nm) are more efficient due to their higher surface/volume ratio. In this work, inductively coupled plasma-mass spectrometry (ICP-MS), flow cytometry (FCM) and transmission electron microscopy (TEM) were combined to obtain insight into the formation of these bio-Pd NPs. The precipitation of bio-Pd NPs was evaluated on a cell-per-cell basis using single-cell ICP-MS (SC-ICP-MS) combined with TEM images to assess how homogenously the particles were distributed over the cells. The results provided by SC-ICP-MS were consistent with those provided by "bulk" ICP-MS analysis and FCM. It was observed that heterogeneity in the distribution of palladium over an entire cell population is strongly dependent on the Pd2+ concentration, biomass and partial H2 pressure. The latter three parameters affected the particle size, ranging from 15.6 to 560 nm, and exerted a significant impact on the production of the bio-Pd NPs. The TEM combined with SC-ICP-MS revealed that the mass distribution for bacteria with high Pd content (144 fg Pd cell-1 ) indicated the presence of a large number of very small NPs (D50 = 15.6 nm). These results were obtained at high cell density (1 × 105 ± 3 × 104 cells µl-1 ) and H2 partial pressure (180 ml H2 ). In contrast, very large particles (D50 = 560 nm) were observed at low cell density (3 × 104 ± 10 × 102 cells µl-1 ) and H2 partial pressure (10-100 ml H2 ). The influence of the H2 partial pressure on the nanoparticle size and the possibility of size-tuned nanoparticles are presented.
Subject(s)
Metal Nanoparticles , Palladium , Partial Pressure , Mass Spectrometry/methods , Spectrum AnalysisABSTRACT
This study describes an interlaboratory comparison (ILC) among nine (9) laboratories to evaluate and validate the standard operation procedure (SOP) for single-particle (sp) ICP-TOFMS developed within the context of the Horizon 2020 project ACEnano. The ILC was based on the characterization of two different Pt nanoparticle (NP) suspensions in terms of particle mass, particle number concentration, and isotopic composition. The two Pt NP suspensions were measured using icpTOF instruments (TOFWERK AG, Switzerland). Two Pt NP samples were characterized and mass equivalent spherical sizes (MESSs) of 40.4 ± 7 nm and 58.8 ± 8 nm were obtained, respectively. MESSs showed <16% relative standard deviation (RSD) among all participating labs and <4% RSD after exclusion of the two outliers. A good agreement was achieved between the different participating laboratories regarding particle mass, but the particle number concentration results were more scattered, with <53% RSD among all laboratories, which is consistent with results from previous ILC studies conducted using ICP-MS instrumentation equipped with a sequential mass spectrometer. Additionally, the capabilities of sp-ICP-TOFMS to determine masses on a particle basis are discussed with respect to the potential for particle density determination. Finally, because quasi-simultaneous multi-isotope and multi-element determinations are a strength of ICP-TOFMS instrumentation, the precision and trueness of isotope ratio determinations were assessed. The average of 1000 measured particles yielded a precision of below ±1% for intensity ratios of the most abundant Pt isotopes, i.e.194Pt and 195Pt, while the accuracy of isotope ratios with the lower abundant isotopes was limited by counting statistics.
ABSTRACT
Biolistic intracellular delivery of functional macromolecules makes use of dense microparticles which are ballistically fired onto cells with a pressurized gun. While it has been used to transfect plant cells, its application to mammalian cells has met with limited success mainly due to high toxicity. Here we present a more refined nanotechnological approach to biolistic delivery with light-triggered self-assembled nanobombs (NBs) that consist of a photothermal core particle surrounded by smaller nanoprojectiles. Upon irradiation with pulsed laser light, fast heating of the core particle results in vapor bubble formation, which propels the nanoprojectiles through the cell membrane of nearby cells. We show successful transfection of both adherent and non-adherent cells with mRNA and pDNA, outperforming electroporation as the most used physical transfection technology by a factor of 5.5-7.6 in transfection yield. With a throughput of 104-105 cells per second, biolistic delivery with NBs offers scalable and highly efficient transfections of mammalian cells.
Subject(s)
Biolistics , Nanotechnology , Animals , Biolistics/methods , Macromolecular Substances , Mammals , Plant Cells , TransfectionABSTRACT
Single cell - tandem ICP-mass spectrometry (SC-ICP-MS/MS) was used for the determination of the absolute amount of Pt (coming from exposure to various concentration levels of cisplatin as a chemotherapeutic drug) and five endogenous elements (P, S, Fe, Cu and Zn) in individual human cells of three different types - Raji, Jurkat and Y79. Optimum conditions were obtained by using a sample introduction unit transporting cell suspension containing approx. 5 × 104 cells per mL at a flow rate of 10 µL min-1 to a nebulizer with narrow internal diameter (250 µm i.d.), mounted onto a total consumption spray chamber. Interference-free conditions were obtained in tandem MS mode (i) for P and S by pressurizing the collision/reaction cell (CRC) with O2 and monitoring the PO+ and SO + reaction product ions and (ii) for Fe by pressurizing the CRC with NH3 and monitoring the Fe(NH3)2+ reaction product ion. The quantification approach was validated by comparison of the absolute amounts of the target elements (in fg per cell) as obtained using SC-ICP-MS/MS with those obtained after acid digestion of approx. 2 × 106 cells and subsequent solution ICP-MS/MS analysis ("bulk" analysis). A higher Pt cell content was observed upon increasing the concentration of the cisplatin solution the cells were exposed to during 24 h. The Pt mass per cell (fg) increased linearly as a function of the cisplatin concentration, but a higher Pt uptake was found in the case of Jurkat cells compared to the other cell types. A cell viability assay showed a lack of chemosensitivity to cisplatin below 200 µM for the Raji and Y79 cell line, but an IC50 value of 11.1 ± 1.3 µM for Jurkat cells. This difference in chemo-responsiveness between the different cell types supported the difference in Pt uptake as indicated via SC-ICP-MS analysis. The increasing level of Pt did not have a marked effect on the contents of the endogenous elements monitored in Raji and Y79 cells, but a decrease in the P and S cell content upon increasing cisplatin treatment was observed for Jurkat cells. This can most likely be attributed to stress induced by the chemotherapeutic treatment in cells showing chemosensitivity towards cisplatin. The results also indicate differences in the absolute amount of endogenous element per cell between different cell types, suggesting the potential of SC-ICP-MS as a "metallo-fingerprinting" tool.
Subject(s)
Pharmaceutical Preparations , Tandem Mass Spectrometry , Cisplatin , Humans , Spectrum AnalysisABSTRACT
Different approaches for the determination of the 87Sr/86Sr isotope ratio of high-Rb glass are compared in this work to assess the suitability of minimally invasive approaches for applications on medieval stained glass (from the ancient Abbey of Stavelot in Belgium). It was found that pneumatic nebulization multicollector inductively coupled plasma-mass spectrometry (PN-MC-ICP-MS) after acid digestion and chromatographic isolation of the target analyte out of the sample matrix can still be seen as the preferred method for the high-precision isotopic analysis of Sr in glass with high Rb and rare-earth element (REE) concentrations. Alternatively, the use of laser ablation (LA) for sample introduction is a powerful technique for the direct analysis of solid samples. However, both the high Rb/Sr ratios in the samples of interest and the presence of REEs at sufficiently high concentrations lead to a large bias in LA-MC-ICP-MS, which cannot be corrected for, even by operating the MC-ICP-MS instrument at higher mass resolution and/or using mathematical corrections. It was demonstrated that LA tandem-ICP-MS (LA-ICP-MS/MS) using CH3F/He as the reaction gas to overcome spectral overlap in a mass-shift approach (chemical resolution) provides a viable alternative when (quasi) nondestructive analysis is required. This approach relies on the monitoring of Sr+ (m/z = 86, 87, and 88) ions as the corresponding SrF+ reaction product ions (m/z = 105, 106, and 107), thus avoiding the occurrence of spectral interference. Self-evidently, the isotope ratio precision attainable using sequential quadrupole-based ICP-MS instrumentation (0.3% RSD) was found to be significantly worse than that of high-precision MC-ICP-MS (0.03% RSD) with simultaneous detection, although it was still fit for the purpose of current applications. In addition to Sr isotopic analysis, the REE patterns and their potential influence on the Sr isotopic composition were evaluated by LA-ICP-MS.
ABSTRACT
Photodynamic and photothermal cell killing at the surface of tissues finds applications in medicine. However, a lack of control over heat dissipation following a treatment with light might damage surrounding tissues. A new strategy to kill cells at the surface of tissues is reported. Polymeric films are designed in which iron oxide nanoparticles are embedded as photosensitizers. Irradiation of the films with pulsed laser light generates water vapor bubbles at the surface of the films. It is found that "bubble-films" can kill cells in close proximity to the films due to mechanical forces which arise when the bubbles collapse. Local irradiation of bubble-films allows for spatial selective single cell killing. As nanosurgery becomes attractive in ophthalmology to remove superficial tumors, bubble-films are applied on the cornea and it is found that irradiation of the bubble-films allows spatial and selective killing of corneal cells. As i) the photosensitizer is embedded in the films, which reduces its uptake by cells and spreading into tissues and ii) the bubble-films can be removed from the tissue after laser treatment, while iii) a low laser fluence is sufficient to generate vapor bubbles, it is foreseen that bubble-films might become promising for safe resection of superficial tumors.
Subject(s)
Lasers , Pulmonary Alveoli , Air , Cell Death , CorneaABSTRACT
Longitudinal in vivo monitoring of transplanted cells is crucial to perform cancer research or to assess the treatment outcome of cell-based therapies. While several bio-imaging techniques can be used, magnetic resonance imaging (MRI) clearly stands out in terms of high spatial resolution and excellent soft-tissue contrast. However, MRI suffers from low sensitivity, requiring cells to be labeled with high concentrations of contrast agents. An interesting option is to label cells with clinically approved gadolinium chelates which generate a hyperintense MR signal. However, spontaneous uptake of the label via pinocytosis results in its endosomal sequestration, leading to quenching of the T1-weighted relaxation. To avoid this quenching effect, delivery of gadolinium chelates directly into the cytosol via electroporation or hypotonic cell swelling have been proposed. However, these methods are also accompanied by several drawbacks such as a high cytotoxicity, and changes in gene expression and phenotype. Here, we demonstrate that nanoparticle-sensitized laser induced photoporation forms an attractive alternative to efficiently deliver the contrast agent gadobutrol into the cytosol of both HeLa and SK-OV-3 IP1 cells. After intracellular delivery by photoporation the quenching effect is clearly avoided, leading to a strong increase in the hyperintense T1-weighted MR signal. Moreover, when compared to nucleofection as a state-of-the-art electroporation platform, photoporation has much less impact on cell viability, which is extremely important for reliable cell tracking studies. Additional experiments confirm that photoporation does not induce any change in the long-term viability or the migratory capacity of the cells. Finally, we show that gadolinium 'labeled' SK-OV-3 IP1 cells can be imaged in vivo by MRI with high soft-tissue contrast and spatial resolution, revealing indications of potential tumor invasion or angiogenesis.