Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
Phys Rev Lett ; 124(2): 023601, 2020 Jan 17.
Article in English | MEDLINE | ID: mdl-32004051

ABSTRACT

Recent optomechanical experiments have observed nonclassical properties in macroscopic mechanical oscillators. A key indicator of such properties is the asymmetry in the strength of the motional sidebands produced in the probe electromagnetic field, which is originated by the noncommutativity between the oscillator ladder operators. Here we extend the analysis to a squeezed state of an oscillator embedded in an optical cavity, produced by the parametric effect originated by a suitable combination of optical fields. The motional sidebands assume a peculiar shape, related to the modified system dynamics, with asymmetric features revealing and quantifying the quantum component of the squeezed oscillator motion.

2.
Phys Rev Lett ; 116(10): 103601, 2016 Mar 11.
Article in English | MEDLINE | ID: mdl-27015479

ABSTRACT

We report the experimental observation of two-mode squeezing in the oscillation quadratures of a thermal micro-oscillator. This effect is obtained by parametric modulation of the optical spring in a cavity optomechanical system. In addition to stationary variance measurements, we describe the dynamic behavior in the regime of pulsed parametric excitation, showing an enhanced squeezing effect surpassing the stationary 3 dB limit. While the present experiment is in the classical regime, our technique can be exploited to produce entangled, macroscopic quantum optomechanical modes.

3.
Phys Rev Lett ; 112(2): 023601, 2014 Jan 17.
Article in English | MEDLINE | ID: mdl-24484010

ABSTRACT

We report the confinement of an optomechanical micro-oscillator in a squeezed thermal state, obtained by parametric modulation of the optical spring. We propose and implement an experimental scheme based on parametric feedback control of the oscillator, which stabilizes the amplified quadrature while leaving the orthogonal one unaffected. This technique allows us to surpass the -3 dB limit in the noise reduction, associated with parametric resonance, with a best experimental result of -7.4 dB. While the present experiment is in the classical regime, in a moderately cooled system our technique may allow squeezing of a macroscopic mechanical oscillator below the zero-point motion.

4.
Hernia ; 26(4): 1063-1068, 2022 08.
Article in English | MEDLINE | ID: mdl-34661771

ABSTRACT

PURPOSE: Aim of this study was to analyse feasibility, safety and effectiveness of laparoscopic transperitoneal hernia repair (TAPP) approach to inguinal hernias in the emergency setting, with a longer follow-up than the studies present in literature. METHODS: We retrospectively analysed all patients who underwent emergency TAPP hernia repair in San Marco Hospital (Zingonia, Italy), from September 2010 to June 2020. A prospectively collected database of 685 consecutive TAPP hernia repair was reviewed. Feasibility and safety were evaluated through operative time, conversion rate, perioperative mortality, morbidity and prosthesis infection rate. Effectiveness was assessed by recurrence and complication rate, acute (during admission) and chronic (during follow-up) pain by Visual Analogic Scale (VAS), and recovery to normal activity in a long-term follow-up (mean period 1718 days). RESULTS: The final study group included 47 patients. The mean age was 59.6 years (range 22-89), 29 patients were male and 18 were female. The mean operation time was 64 min. Two cases were converted to open approach (4%). In four cases bowel resection became necessary (8.5%). Appendicectomy and omentectomy occurred once and twice, respectively (2% and 4%), and orchiectomy was required in two patients (4%). Seroma was the only postoperative complication that we registered in four patients. During a mean follow-up period of 1718 days, there was no recurrence of the hernia or other complications. Five patients referred mild occasional groin pain (VAS < 3), with quick relief without taking any pain killers. CONCLUSION: TAPP approach is a safe, feasible and effective therapeutic option for groin hernias in emergency setting. No recurrence or severe complications were reported in over 4 years of follow-up.


Subject(s)
Hernia, Inguinal , Laparoscopy , Adult , Aged , Aged, 80 and over , Female , Follow-Up Studies , Hernia, Inguinal/etiology , Hernia, Inguinal/surgery , Herniorrhaphy/adverse effects , Humans , Laparoscopy/adverse effects , Male , Middle Aged , Pain/etiology , Retrospective Studies , Surgical Mesh , Treatment Outcome , Young Adult
5.
Rev Sci Instrum ; 79(3): 033901, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18377019

ABSTRACT

A setup for measuring mechanical losses of silicon wafers has been fully characterized from room temperature to 4 K in the frequency range between 300 Hz and 4 kHz: it consists of silicon wafers with nodal suspension and capacitive and optical vibration sensors. Major contributions to mechanical losses are investigated and compared with experimental data scanning the full temperature range; in particular, losses due to the thermoelastic effect and to the wafer clamp are modeled via finite element method analysis; surface losses and gas damping are also estimated. The reproducibility of the measurements of total losses is also discussed and the setup capabilities for measuring additive losses contributed by thin films deposited on the wafers or bonding layers. For instance, assuming that additive losses are due to an 80-nm-thick wafer bond layer with Young modulus about ten times smaller than that of silicon, we achieve a sensitivity to bond losses at the level of 5x10(-3) at 4 K and at about 2 kHz.

6.
J Surg Case Rep ; 2017(3): rjw220, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28458842

ABSTRACT

Right diaphragmatic hernia is an uncommon injury following abdominal trauma. A case of delayed right post-traumatic diaphragmatic hernia is presented. The patient referred us with wheezing and cough since 1 month. A chest-abdominal computed tomography scan demonstrated a large diaphragmatic defect with liver and intestinal dislocation. The patient underwent surgical intervention with diaphragmatic repair. No complications were observed during admission and follow-up is actually negative for recurrence.

7.
J Surg Case Rep ; 2017(3): rjx037, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28458847

ABSTRACT

Black esophagus is a rare, multifactorial disease. A case of acute black esophagus following pancreatic resection is presented. The patient referred us with a specific gastrointestinal bleeding. An esophagogastroduodenoscopy confirmed the diagnosis. We performed conservative treatment with complete esophageal re-epithelization and negative follow-up for stenosis or necrosis relapse.

8.
Phys Rev Lett ; 85(24): 5046-50, 2000 Dec 11.
Article in English | MEDLINE | ID: mdl-11102183

ABSTRACT

We report the initial results from a search for bursts of gravitational radiation by a network of five cryogenic resonant detectors during 1997 and 1998. This is the first significant search with more than two detectors observing simultaneously. No gravitational wave burst was detected. The false alarm rate was lower than 1 per 10(4) yr when three or more detectors were operating simultaneously. The typical threshold was H approximately 4x10(-21) Hz-1 on the Fourier component at approximately 10(3) Hz of the gravitational wave strain amplitude. New upper limits for amplitude and rate of gravitational wave bursts have been set.

9.
Thromb Haemost ; 112(6): 1129-36, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25104514

ABSTRACT

After a proximal deep-vein thrombosis (P-DVT), the risk of diagnosis of a previously unsuspected cancer is high. Isolated distal DVT (iD-DVT; i.e. infra-popliteal DVT without pulmonary embolism [PE]) and isolated superficial-vein thrombosis (iSVT; i.e. without concomitant DVT and PE) are at least as frequent as P-DVT but their association with subsequent cancer is uncertain. We exploited data from the OPTIMEV prospective, observational, multicentre study to i) compare the risk of subsequent cancer three years after a first objectively confirmed iSVT, iD-DVT and iP-DVT in patients without a prior history of cancer or of venous thromboembolism, ii) assess predictors of subsequent cancer in cases of iD-DVT. The overall cumulative rates of cancer among the 304 patients with iSVT, 536 patients with iD-DVT, and 327 patients with iP-DVT were similar (3.4% 95% confidence interval [1.8-6.2], 3.9% [2.5-5.9] and 3.9% [2.3-6.8], respectively), regardless of whether the index venous thromboembolic event was unprovoked or associated with a major transient risk factor. Neither anatomical (muscular vs deep-calf DVT) nor ultrasound scan characteristics (number of thrombosed veins, clot diameter under compression) seemed strongly associated with the risk of cancer in cases of iD-DVT. In patients managed in routine practice, all the different clinical expressions of lower limb venous thromboembolism are associated with a similar risk of subsequent cancer. From a clinical practice point of view, this suggests that cancer screening, without discussing the necessity, or not, of such screening, should not differ between a deep-proximal, deep-distal or superficial location of thrombosis.


Subject(s)
Lower Extremity/blood supply , Neoplasms/epidemiology , Venous Thrombosis/epidemiology , Aged , Cause of Death , Female , France/epidemiology , Humans , Incidence , Male , Middle Aged , Neoplasms/diagnosis , Neoplasms/mortality , Prognosis , Prospective Studies , Risk Assessment , Risk Factors , Time Factors , Ultrasonography , Venous Thrombosis/diagnostic imaging , Venous Thrombosis/mortality , Venous Thrombosis/therapy
10.
Phys Rev B Condens Matter ; 42(16): 9865-9874, 1990 Dec 01.
Article in English | MEDLINE | ID: mdl-9995239
13.
Phys Rev B Condens Matter ; 39(16): 11993-12002, 1989 Jun 01.
Article in English | MEDLINE | ID: mdl-9948035
14.
Phys Rev Lett ; 103(1): 010601, 2009 Jul 03.
Article in English | MEDLINE | ID: mdl-19659131

ABSTRACT

We analyze heat and work fluctuations in the gravitational wave detector AURIGA, modeled as a macroscopic electromechanical oscillator in contact with a thermostat and cooled by an active feedback system. The oscillator is driven to a steady state by the feedback cooling, equivalent to a viscous force. The experimentally measured fluctuations are in agreement with our theoretical analysis based on a stochastically driven Langevin system. The asymmetry of the fluctuations of the absorbed heat characterizes the oscillator's nonequilibrium steady state and reveals the extent to which a feedback cooled system departs from equilibrium in a statistical mechanics perspective.

16.
Phys Rev Lett ; 101(3): 033601, 2008 Jul 18.
Article in English | MEDLINE | ID: mdl-18764254

ABSTRACT

We apply a feedback cooling technique to simultaneously cool the three electromechanical normal modes of the ton-scale resonant-bar gravitational wave detector AURIGA. The measuring system is based on a dc superconducting quantum interference device (SQUID) amplifier, and the feedback cooling is applied electronically to the input circuit of the SQUID. Starting from a bath temperature of 4.2 K, we achieve a minimum temperature of 0.17 mK for the coolest normal mode. The same technique, implemented in a dedicated experiment at subkelvin bath temperature and with a quantum limited SQUID, could allow to approach the quantum ground state of a kilogram-scale mechanical resonator.

17.
Phys Rev Lett ; 95(8): 081103, 2005 Aug 19.
Article in English | MEDLINE | ID: mdl-16196848

ABSTRACT

At the time when the giant flare of SGR1806-20 occurred, the AURIGA "bar" gravitational-wave (GW) detector was on the air with a noise performance close to stationary Gaussian. This allows us to set relevant upper limits, at a number of frequencies in the vicinities of 900 Hz, on the amplitude of the damped GW wave trains, which, according to current models, could have been emitted, due to the excitation of normal modes of the star associated with the peak in x-ray luminosity.

18.
J Eukaryot Microbiol ; 48(1): 95-101, 2001.
Article in English | MEDLINE | ID: mdl-11249198

ABSTRACT

The trichites of Strombidium and related genera have been considered either as a cytoskeletal armature or as extrusomes. To demonstrate their true nature, a study was undertaken on two marine Strombidium species by ultrastructural and cytochemical analysis as well as in vivo experiments. Trichites, extending from the cortex into the cell, are rod-shaped, membrane-bounded, and have a complex structure. The following elements of the trichites, are distinguishable: an electron-transparent lumen, a laminated layer, and a compact layer. In trichites of one species, thin "rings" surround the lumen. Numerous short, curved tubules with a polysaccharide wall are present in the cytoplasm surrounding the trichites. At the cortical end, each trichite is enveloped by a "cap" of electron-dense proteinaceous material. In some cases, the cortical alveoli appear interrupted, forming a "hole" for trichite ejection. Ejection of rod-shaped structures, up to 5 times longer than resting trichites, was obtained by in vivo treatments with dextran and aminoethyldextran. Negative staining indicated that these structures were transformed trichites. As no other possible extrusive structures were observed in the cytoplasm of Strombidium, trichites were considered extrusomes.


Subject(s)
Ciliophora/ultrastructure , Organelles/physiology , Organelles/ultrastructure , Animals , Ciliophora/growth & development , Cytoskeleton/ultrastructure , Histocytochemistry/methods , Microscopy, Electron , Organelles/chemistry , Seawater/parasitology
SELECTION OF CITATIONS
SEARCH DETAIL