Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
J Chemom ; 32(2)2018 Feb.
Article in English | MEDLINE | ID: mdl-29795964

ABSTRACT

With the increasing availability of digital imaging devices, colorimetric sensor arrays are rapidly becoming a simple, yet effective tool for the identification and quantification of various analytes. Colorimetric arrays utilize colorimetric data from many colorimetric sensors, with the multidimensional nature of the resulting data necessitating the use of chemometric analysis. Herein, an 8 sensor colorimetric array was used to analyze select acid and basic samples (0.5 - 10 M) to determine which chemometric methods are best suited for classification quantification of analytes within clusters. PCA, HCA, and LDA were used to visualize the data set. All three methods showed well-separated clusters for each of the acid or base analytes and moderate separation between analyte concentrations, indicating that the sensor array can be used to identify and quantify samples. Furthermore, PCA could be used to determine which sensors showed the most effective analyte identification. LDA, KNN, and HQI were used for identification of analyte and concentration. HQI and KNN could be used to correctly identify the analytes in all cases, while LDA correctly identified 95 of 96 analytes correctly. Additional studies demonstrated that controlling for solvent and image effects was unnecessary for all chemometric methods utilized in this study.

2.
Electrophoresis ; 30(4): 657-60, 2009 Feb.
Article in English | MEDLINE | ID: mdl-19156771

ABSTRACT

The use of 18-crown-6 as a class I organic modifier for SDS MEKC is described. Two positional isomer series, one neutral (nitrotoluenes) and one anionic (nitrophenols), are used to demonstrate different effects of 18-crown-6 on analyte retention in SDS MEKC.


Subject(s)
Chromatography, Micellar Electrokinetic Capillary/methods , Crown Ethers/chemistry , Nitrophenols/chemistry , Sodium Dodecyl Sulfate/chemistry , Toluene/analogs & derivatives
3.
Anal Bioanal Chem ; 395(2): 301-13, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19644679

ABSTRACT

The increased use of peroxide-based explosives (PBEs) in criminal and terrorist activity has created a demand for continued innovation in the detection of these agents. This review provides an update to a previous 2006 review on the detection of PBEs, with a focus in this report on luminescence and fluorescence methods, infrared and Raman spectroscopy, mass spectrometry, and electrochemical techniques. Newer developments in gas chromatography and high performance liquid chromatography methods are also discussed. One recent trend that is discussed is an emphasis on field measurements through the use of portable instruments or portable assay formats. An increase in the use of infrared spectroscopy and mass spectrometry for PBE analysis is also noted. The analysis of triacetone triperoxide has been the focus in the development of many of these methods, although hexamethylene triperoxide diamine has received increased attention in PBE detection during the last few years.

4.
Int J Chem ; 10(2): 36-55, 2018.
Article in English | MEDLINE | ID: mdl-31745401

ABSTRACT

Colorimetric sensor arrays incorporating red, green, and blue (RGB) image analysis use value changes from multiple sensors for the identification and quantification of various analytes. RGB data can be easily obtained using image analysis software such as ImageJ. Subsequent chemometric analysis is becoming a key component of colorimetric array RGB data analysis, though literature contains mainly principal component analysis (PCA) and hierarchical cluster analysis (HCA). Seeking to expand the chemometric methods toolkit for array analysis, we explored the performance of nine chemometric methods were compared for the task of classifying 631 solutions (0.1 to 3 M) of acetic acid, malonic acid, lysine, and ammonia using an eight sensor colorimetric array. PCA and LDA (linear discriminant analysis) were effective for visualizing the dataset. For classification, linear discriminant analysis (LDA), (k nearest neighbors) KNN, (soft independent modelling by class analogy) SIMCA, recursive partitioning and regression trees (RPART), and hit quality index (HQI) were very effective with each method classifying compounds with over 90% correct assignments. Support vector machines (SVM) and partial least squares - discriminant analysis (PLS-DA) struggled with ~85 and 39% correct assignments, respectively. Additional mathematical treatments of the data set, such as incrementally increasing the exponents, did not improve the performance of LDA and KNN. The literature precedence indicates that the most common methods for analyzing colorimetric arrays are PCA, LDA, HCA, and KNN. To our knowledge, this is the first report of comparing and contrasting several more diverse chemometric methods to analyze the same colorimetric array data.

5.
Crit Rev Anal Chem ; 47(2): 138-153, 2017 Mar 04.
Article in English | MEDLINE | ID: mdl-27636675

ABSTRACT

There is a significant demand for devices that can rapidly detect chemical-biological-explosive (CBE) threats on-site and allow for immediate responders to mitigate spread, risk, and loss. The key to an effective reconnaissance mission is a unified detection technology that analyzes potential threats in real time. In addition to reviewing the current state of the art in the field, this review illustrates the practicality of colorimetric arrays composed of sensors that change colors in the presence of analytes. This review also describes an outlook toward future technologies, and describes how they could possibly be used in areas such as war zones to detect and identify hazardous substances.


Subject(s)
Chemical Warfare , Colorimetry/methods , Explosive Agents/analysis , Colorimetry/instrumentation , Hazardous Substances/analysis
6.
J Forensic Sci ; 55(3): 723-7, 2010 May.
Article in English | MEDLINE | ID: mdl-20202067

ABSTRACT

The design and preliminary characterization of a novel sensor for drugs of abuse, DETECHIP, is described in this proof-of-concept note. Combining both colorimetric and fluorimetric assays, DETECHIP is suitable for lab and field use. More than a conventional spot test which provides a single "yes or no" answer, DETECHIP provides twenty responses for a more complete characterization of suspect material. This is accomplished by visually noting colorimetric and fluorescent changes of carefully selected dyes upon the addition of test analytes, including drugs of abuse, with respect to controls. Color and fluorescence changes are recorded numerically so that a 20 digit identification code can be constructed for comparison of test analytes and known compounds. DETECHIP is applicable to a variety of drugs, both plant-derived and synthetic, addressing the need to use several different spot tests simultaneously for a single sample.


Subject(s)
Narcotics/chemistry , Substance Abuse Detection/instrumentation , Colorimetry , Coloring Agents , Drug Contamination , Fluorometry , Forensic Toxicology/instrumentation , Humans , Illicit Drugs/chemistry , Nonprescription Drugs/chemistry , Spectrophotometry , Substance Abuse Detection/methods
SELECTION OF CITATIONS
SEARCH DETAIL