Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 49
Filter
1.
Eur Heart J ; 2024 May 15.
Article in English | MEDLINE | ID: mdl-38747561

ABSTRACT

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

2.
N Engl J Med ; 380(18): 1706-1715, 2019 05 02.
Article in English | MEDLINE | ID: mdl-30883053

ABSTRACT

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis who are at increased risk for death from surgery; less is known about TAVR in low-risk patients. METHODS: We performed a randomized noninferiority trial in which TAVR with a self-expanding supraannular bioprosthesis was compared with surgical aortic-valve replacement in patients who had severe aortic stenosis and were at low surgical risk. When 850 patients had reached 12-month follow-up, we analyzed data regarding the primary end point, a composite of death or disabling stroke at 24 months, using Bayesian methods. RESULTS: Of the 1468 patients who underwent randomization, an attempted TAVR or surgical procedure was performed in 1403. The patients' mean age was 74 years. The 24-month estimated incidence of the primary end point was 5.3% in the TAVR group and 6.7% in the surgery group (difference, -1.4 percentage points; 95% Bayesian credible interval for difference, -4.9 to 2.1; posterior probability of noninferiority >0.999). At 30 days, patients who had undergone TAVR, as compared with surgery, had a lower incidence of disabling stroke (0.5% vs. 1.7%), bleeding complications (2.4% vs. 7.5%), acute kidney injury (0.9% vs. 2.8%), and atrial fibrillation (7.7% vs. 35.4%) and a higher incidence of moderate or severe aortic regurgitation (3.5% vs. 0.5%) and pacemaker implantation (17.4% vs. 6.1%). At 12 months, patients in the TAVR group had lower aortic-valve gradients than those in the surgery group (8.6 mm Hg vs. 11.2 mm Hg) and larger effective orifice areas (2.3 cm2 vs. 2.0 cm2). CONCLUSIONS: In patients with severe aortic stenosis who were at low surgical risk, TAVR with a self-expanding supraannular bioprosthesis was noninferior to surgery with respect to the composite end point of death or disabling stroke at 24 months. (Funded by Medtronic; ClinicalTrials.gov number, NCT02701283.).


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Prosthesis Design , Stroke/etiology , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aortic Valve Insufficiency/etiology , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/mortality , Atrial Fibrillation/etiology , Bayes Theorem , Echocardiography , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Kaplan-Meier Estimate , Length of Stay , Male , Postoperative Complications/epidemiology , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects
3.
Catheter Cardiovasc Interv ; 95(5): 1051-1056, 2020 04 01.
Article in English | MEDLINE | ID: mdl-31478304

ABSTRACT

OBJECTIVES: This multicenter retrospective study of the initial U.S. experience evaluated the safety and efficacy of temporary cardiac pacing with the Tempo® Temporary Pacing Lead. BACKGROUND: Despite increasing use of temporary cardiac pacing with the rapid growth of structural heart procedures, temporary pacing leads have not significantly improved. The Tempo lead is a new temporary pacing lead with a soft tip intended to minimize the risk of perforation and a novel active fixation mechanism designed to enhance lead stability. METHODS: Data from 269 consecutive structural heart procedures were collected. Outcomes included device safety (absence of clinically significant cardiac perforation, new pericardial effusion, or sustained ventricular arrhythmia) and efficacy (clinically acceptable pacing thresholds with successful pace capture throughout the index procedure). Postprocedure practices and sustained lead performance were also analyzed. RESULTS: The Tempo lead was successfully positioned in the right ventricle and achieved pacing in 264 of 269 patients (98.1%). Two patients (0.8%) experienced loss of pace capture. Procedural mean pace capture threshold (PCT) was 0.7 ± 0.8 mA. There were no clinically significant perforations, pericardial effusions, or sustained device-related arrhythmias. The Tempo lead was left in place postprocedure in 189 patients (71.6%) for mean duration of 43.3 ± 0.7 hr (range 2.5-221.3 hr) with final PCT of 0.84 ± 1.04 mA (n = 80). Of these patients, 84.1% mobilized out of bed with no lead dislodgment. CONCLUSION: The Tempo lead is safe and effective for temporary cardiac pacing for structural heart procedures, provides stable peri and postprocedural pacing and allows mobilization of patients who require temporary pacing leads.


Subject(s)
Cardiac Pacing, Artificial , Cardiac Surgical Procedures , Pacemaker, Artificial , Perioperative Care/instrumentation , Aged , Aged, 80 and over , Cardiac Pacing, Artificial/adverse effects , Cardiac Surgical Procedures/adverse effects , Equipment Design , Female , Heart Rate , Humans , Male , Patient Safety , Perioperative Care/adverse effects , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , United States , Ventricular Function, Right
4.
Catheter Cardiovasc Interv ; 93(4): 740-748, 2019 03 01.
Article in English | MEDLINE | ID: mdl-30341970

ABSTRACT

OBJECTIVES: To assess the treatment effect of TAVR versus SAVR on clinical outcomes to 3 years in patients stratified by chronic kidney disease (CKD) by retrospectively studying patients randomized to TAVR or SAVR. BACKGROUND: The impact of CKD on mid-term outcomes of patients undergoing TAVR versus SAVR is unclear. METHODS: Patients randomized to TAVR or SAVR in the CoreValve US Pivotal High Risk Trial were retrospectively stratified by eGFR: none/mild or moderate/severe CKD. To evaluate the impact of baseline CKD in TAVR patients only, all patients undergoing an attempted TAVR implant in the US Pivotal Trial and CAS were stratified by baseline eGFR into none/mild, moderate, and severe CKD. The primary endpoint was major adverse cardiovascular and renal events (MACRE), a composite of all-cause mortality, myocardial infarction, stroke/TIA, and new requirement of dialysis. RESULTS: Moderate/severe CKD was present in 62.7% and 60.7% of high-risk patients randomized to TAVR or SAVR, respectively. Baseline characteristics were similar between TAVR and SAVR patients in both CKD subgroups, except for higher rates of diabetes and higher serum creatinine in SAVR patients. Among high-risk patients with moderate/severe CKD, TAVR provided a lower 3-year MACRE rate compared with SAVR: 42.1% vs. 51.0, P = .04. Of 3,733 extreme- and high-risk TAVR patients, 39.9% had none/mild, 53.8% moderate, and 6.4% severe CKD. Worsening baseline CKD was associated with increased 3-year MACRE rates [none/mild 51.5%, moderate 54.5%, severe 63.1%, P = .001]. CONCLUSIONS: TAVR results in lower 3-year MACRE versus SAVR in high-risk patients with moderate/severe CKD. In patients undergoing TAVR, worsening CKD increases mid-term mortality and MACRE. Randomized trials of TAVR vs. SAVR in patients with moderate-severe CKD would help elucidate the best treatment for these complex patients. TRIAL REGISTRATION: CoreValve US Pivotal Trial: NCT01240902. CoreValve Continued Access Study: NCT01531374.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Glomerular Filtration Rate , Heart Valve Prosthesis Implantation , Kidney/physiopathology , Renal Insufficiency, Chronic/physiopathology , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Female , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/mortality , Humans , Male , Randomized Controlled Trials as Topic , Renal Dialysis , Renal Insufficiency, Chronic/diagnosis , Renal Insufficiency, Chronic/mortality , Renal Insufficiency, Chronic/therapy , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , United States
5.
Catheter Cardiovasc Interv ; 87(3): 376-80, 2016 Feb 15.
Article in English | MEDLINE | ID: mdl-26489781

ABSTRACT

OBJECTIVE: To assess the impact of simulation training on complications associated with femoral arterial access obtained by first year cardiology fellows. BACKGROUND: Prior studies demonstrate a higher incidence of arterial access related complications among patients undergoing invasive cardiac procedures. METHODS: First year cardiology fellows at four teaching hospitals in Michigan tracked their femoral access experience and any associated complications between July 2011 and June 2013. Fellows starting their academic training in July 2012 were first trained on a specially developed simulator before starting their rotation in the catheterization laboratory. The primary outcome was access proficiency, defined as five successful femoral access attempts without any complication or need to seek help from a more experienced team member. RESULTS: A total of 1,278 femoral access attempts were made by 21 fellows in 2011-2012 compared with 869 femoral access attempts made by 21 fellows in 2012-2013. There was a lower rate of access related complications in patients undergoing access attempts by first year fellows in year 2 compared with year 1 (2.1% versus 4.5%, P = 0.003). The number of procedures to achieve procedural proficiency was significantly higher in year 1 compared with year 2 (median 20 versus 10, P = 0.007). CONCLUSIONS: Incorporation of simulation in the training of first year fellows was associated with an improvement in proficiency and a clinically meaningful reduction in vascular complications.


Subject(s)
Catheterization, Peripheral/methods , Education, Medical, Graduate/methods , Femoral Artery , Models, Anatomic , Models, Cardiovascular , Simulation Training/methods , Catheterization, Peripheral/adverse effects , Clinical Competence , Hospitals, Teaching , Humans , Learning Curve , Michigan
6.
Echocardiography ; 31(8): 947-55, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24446589

ABSTRACT

BACKGROUND: We have developed new universal strain software (USS) that can be used to perform speckle tracking of any Digital Imaging and Communications in Medicine (DICOM) image, regardless of the ultrasound system used to obtain it. METHODS: Fifty patients prospectively underwent echocardiography immediately prior to cardiac catheterization. Biplane peak global longitudinal strain (GLS), peak systolic longitudinal strain rate (SSR), peak early diastolic longitudinal strain rate (DSR), and peak early diastolic circumferential strain rate (DCSR) were determined using conventional strain software (CSS) that uses raw data, and using the new USS applied to DICOM images. RESULTS: Universal strain software correlated with CSS for GLS (r = 0.78, P < 0.001), SSR (r = 0.78, P < 0.001), DSR (r = 0.54, P < 0.001), and DCSR (r = 0.43, P = 0.019). GLS and SSR using USS correlated with left ventricular ejection fraction (LVEF) (r = -0.67 and -0.71, respectively) as well as using CSS (r = -0.66 and -0.71). Patients with diastolic dysfunction had significantly lower DSR (0.61 vs. 0.87/sec, P = 0.02) and DCSR (0.89 vs. 1.23/sec, P = 0.03), and less negative GLS (-10.8 vs. -16.1%, P = 0.002) using USS in all patients, as well as among those with LVEF ≥ 50%. Receiver-operating characteristic (ROC) analysis for detection of diastolic dysfunction revealed a sensitivity and specificity of 82% and 83% for DCSR < 1.09/sec (area under the curve [AUC = 0.80]) and 85% and 83% for GLS > -13.7% (AUC = 0.84) using USS. CONCLUSION: Universal strain software can be used to accurately assess LV systolic and diastolic function using speckle tracking echocardiography.


Subject(s)
Algorithms , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Image Interpretation, Computer-Assisted/methods , Software , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/physiopathology , Diastole , Elastic Modulus , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Software Validation , Stress, Mechanical , Stroke Volume , Systole , Ultrasonography
7.
Article in English | MEDLINE | ID: mdl-38871537

ABSTRACT

BACKGROUND: Permanent pacemaker implantation (PPI) rates following transcatheter aortic valve replacement (TAVR) remain a concern. We assessed the PPI rates over time in patients implanted with an Evolut supra-annular, self-expanding transcatheter valve from the US STS/ACC TVT Registry. METHODS: Patients who underwent TAVR with an Evolut R, Evolut PRO or Evolut PRO+ valve between July 2018 (Q3) and June 2021 (Q2) were included. PPI rates were reported by calendar quarter. In-hospital PPI rates were reported as proportions and 30-day rates as Kaplan-Meier estimates. A Cox regression model was used to determine potential predictors of a new PPI within 30 days of the TAVR procedure. RESULTS: From July 2018 to June 2021, 54,014 TAVR procedures were performed using Evolut valves. Mean age was 79.3 ± 8.8 years and 49.2 % were male. The 30-day PPI rate was 16.6 % in 2018 (Q3) and 10.8 % in 2021 (Q2, 34.9 % decrease, p < 0.001 for trend across all quarters). The in-hospital PPI rate decreased by 40.1 %; from 14.7 % in 2018 (Q3) to 8.8 % in 2021 (Q2) (p < 0.001 for trend across all quarters). Significant predictors of a new PPI within 30 days included a baseline conduction defect, history of atrial fibrillation, home oxygen, and diabetes mellitus. CONCLUSION: From 2018 to 2021, TAVR with an Evolut transcatheter heart valve in over 50,000 patients showed a significant decreasing trend in the rates of in-hospital and 30-day PPI, representing the lowest rate of PPI in any large real-world registry of Evolut. During the same evaluated period, high device success and shorter length of stay was also observed.

8.
JACC Cardiovasc Interv ; 17(14): 1667-1675, 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-39048253

ABSTRACT

BACKGROUND: Outcomes from transcatheter aortic valve replacement (TAVR) in low-surgical risk patients with bicuspid aortic stenosis beyond 2 years are limited. OBJECTIVES: This study aimed to evaluate 3-year clinical and echocardiographic outcomes from the Evolut Low Risk Bicuspid Study. METHODS: The Evolut Low Risk Bicuspid Study is a prospective, multicenter, single-arm study conducted in 25 U.S. CENTERS: Patients with severe aortic stenosis at low surgical risk with bicuspid aortic valve anatomy (all subtypes) underwent TAVR with a self-expanding, supra-annular Evolut R or PRO (Medtronic) bioprosthesis. An independent clinical events committee adjudicated all deaths and endpoint-related adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints. RESULTS: An attempted implant was performed in 150 patients from December 2018 to October 2019. The mean age was 70.3 ± 5.5 years, 48% (72/150) of the patients were women, and the mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 1.3% (Q1-Q3: 0.9%-1.7%). Sievers type 1 was the dominant bicuspid morphology (90.7%, 136/150). The Kaplan-Meier rates of all-cause mortality or disabling stroke were 1.3% (95% CI: 0.3%-5.3%) at 1 year, 3.4% (95% CI: 1.4%-8.1%) at 2 years, and 4.1% (95% CI: 1.6%-10.7%) at 3 years. The incidence of new permanent pacemaker implantation was 19.4% (95% CI: 12.4%-29.6%) at 3 years. There were no instances of moderate or severe paravalvular aortic regurgitation at 2 and 3 years after TAVR. CONCLUSIONS: The 3-year results from the Evolut Low Risk Bicuspid Study demonstrate low rates of all-cause mortality or disabling stroke and favorable hemodynamic performance.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Bicuspid Aortic Valve Disease , Bioprosthesis , Heart Valve Prosthesis , Hemodynamics , Prosthesis Design , Transcatheter Aortic Valve Replacement , Humans , Female , Male , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Risk Factors , Prospective Studies , Time Factors , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/abnormalities , Risk Assessment , Bicuspid Aortic Valve Disease/surgery , Bicuspid Aortic Valve Disease/physiopathology , United States/epidemiology , Severity of Illness Index , Postoperative Complications/mortality , Recovery of Function , Aged, 80 and over , Middle Aged , Heart Valve Diseases/physiopathology , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/surgery , Heart Valve Diseases/mortality
9.
Am J Cardiol ; 214: 1-7, 2024 03 01.
Article in English | MEDLINE | ID: mdl-38110018

ABSTRACT

Transcatheter aortic valve replacement (TAVR) provides an option for extreme-risk patients who underwent reoperation for a failed surgical aortic bioprosthesis. Long-term data on patients who underwent TAVR within a failed surgical aortic valve (TAV-in-SAV) are limited. The CoreValve Expanded Use Study evaluated patients at extreme surgical risk who underwent TAV-in-SAV. Outcomes at 5 years were analyzed by SAV failure mode (stenosis, regurgitation, or combined). Echocardiographic outcomes are site-reported. TAV-in-SAV was attempted in 226 patients with a mean age of 76.7 ± 10.8 years; 63.3% were male, the Society of Thoracic Surgeons predicted risk of mortality score was 9.0 ± 6.7%, and 87.5% had a New York Heart Association classification III or IV symptoms. Most of the failed surgical bioprostheses were stented (81.9%), with an average implant duration of 10.2 ± 4.3 years. The 5-year all-cause mortality or major stroke rate was 47.2% in all patients; 54.4% in the stenosis, 37.6% in the regurgitation, and 38.0% in the combined groups (p = 0.046). At 5 years, all-cause mortality was higher in patients with versus without 30-day severe prosthesis-patient mismatch (51.7% vs 38.3%, p = 0.026). The overall aortic valve reintervention rate was 5.9%; highest in the regurgitation group (12.6%). The mean aortic valve gradient was 14.1 ± 9.8 mm Hg and effective orifice area was 1.57 ± 0.70 at 5 years. Few patients had >mild paravalvular regurgitation at 5 years (5.5% moderate, 0.0% severe). TAV-in-SAV with supra-annular, self-expanding TAVR continues to represent a safe and lasting intermediate option for extreme-risk patients who have appropriate sizing of the preexisting failed surgical valve. Clinical and hemodynamic outcomes were stable through 5 years.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aged , Aged, 80 and over , Female , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Follow-Up Studies , Constriction, Pathologic/etiology , Constriction, Pathologic/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects , Surgical Instruments , Prosthesis Design , Risk Factors
10.
Article in English | MEDLINE | ID: mdl-38599918

ABSTRACT

BACKGROUND: The next generation supra-annular, self-expanding Evolut FX transcatheter aortic valve (TAV) system was designed to improve catheter deliverability, provide stable and symmetric valve deployment, and assess commissural alignment during the procedure. The impact of these modifications has not been clinically evaluated. METHODS: Procedural information was collected by survey in 2 Stages: Stage I comprised 23 centers with extensive experience with Evolut TAV systems, and Stage II comprised an additional 46 centers with a broad range of balloon- and self-expanding system experience. Operators were to compare the experience with the Evolut FX to the predicate Evolut PRO+ system. RESULTS: There were 285 cases during Stage I from June 24 to August 12, 2022, and 254 cases during Stage II from August 15 to September 11, 2022. Overall, the cusp overlap technique was used in 88.6 %, and commissural alignment was achieved in 96.1 % of these cases. Compared to implanter's previous experience with the Evolut PRO+ system, less resistance was noted with the Evolut FX system: in 83.0 % of cases during vascular insertion, in 84.7 % of cases while tracking through the vasculature, in 84.4 % of cases while traversing over the arch, and 76.1 % of cases in advancing across the valve. Better symmetry of valve depth was observed in 423 of 525 cases (80.6 %). CONCLUSION: Evolut FX system design modifications translated into improvements in catheter deliverability, deployment symmetry and stability, and commissural alignment as assessed by experienced self-expanding and balloon expandable operators.

11.
JACC Cardiovasc Interv ; 17(8): 1007-1016, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38573257

ABSTRACT

BACKGROUND: Data on valve reintervention after transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) are limited. OBJECTIVES: The authors compared the 5-year incidence of valve reintervention after self-expanding CoreValve/Evolut TAVR vs SAVR. METHODS: Pooled data from CoreValve and Evolut R/PRO (Medtronic) randomized trials and single-arm studies encompassed 5,925 TAVR (4,478 CoreValve and 1,447 Evolut R/PRO) and 1,832 SAVR patients. Reinterventions were categorized by indication, timing, and treatment. The cumulative incidence of reintervention was compared between TAVR vs SAVR, Evolut vs CoreValve, and Evolut vs SAVR. RESULTS: There were 99 reinterventions (80 TAVR and 19 SAVR). The cumulative incidence of reintervention through 5 years was higher with TAVR vs SAVR (2.2% vs 1.5%; P = 0.017), with differences observed early (≤1 year; adjusted subdistribution HR: 3.50; 95% CI: 1.53-8.02) but not from >1 to 5 years (adjusted subdistribution HR: 1.05; 95% CI: 0.48-2.28). The most common reason for reintervention was paravalvular regurgitation after TAVR and endocarditis after SAVR. Evolut had a significantly lower incidence of reintervention than CoreValve (0.9% vs 1.6%; P = 0.006) at 5 years with differences observed early (adjusted subdistribution HR: 0.30; 95% CI: 0.12-0.73) but not from >1 to 5 years (adjusted subdistribution HR: 0.61; 95% CI: 0.21-1.74). The 5-year incidence of reintervention was similar for Evolut vs SAVR (0.9% vs 1.5%; P = 0.41). CONCLUSIONS: A low incidence of reintervention was observed for CoreValve/Evolut R/PRO and SAVR through 5 years. Reintervention occurred most often at ≤1 year for TAVR and >1 year for SAVR. Most early reinterventions were with the first-generation CoreValve and managed percutaneously. Reinterventions were more common following CoreValve TAVR compared with Evolut TAVR or SAVR.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Postoperative Complications , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Postoperative Complications/surgery , Prosthesis Design , Randomized Controlled Trials as Topic , Risk Assessment , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Incidence , Retreatment
12.
Am J Cardiol ; 213: 99-105, 2024 02 15.
Article in English | MEDLINE | ID: mdl-38110022

ABSTRACT

The association, if any, between the effective regurgitant orifice area (EROA) to left ventricular end-diastolic volume (LVEDV) ratio and 1-year mortality is controversial in patients who undergo mitral transcatheter edge-to-edge repair (m-TEER) with the MitraClip system (Abbott Vascular, Santa Clara, CA). This study's objective was to determine the association between EROA/LVEDV and 1-year mortality in patients who undergo m-TEER with MitraClip. In patients with severe secondary (functional) mitral regurgitation (MR), we analyzed registry data from 11 centers using generalized linear models with the generalized estimating equations approach. We studied 525 patients with secondary MR who underwent m-TEER. Most patients were male (63%) and were New York Heart Association class III (61%) or IV (21%). Mitral regurgitation was caused by ischemic cardiomyopathy in 51% of patients. EROA/LVEDV values varied widely, with median = 0.19 mm2/ml, interquartile range [0.12,0.28] mm2/ml, and 187 patients (36%) had values <0.15 mm2/ml. Postprocedural mitral regurgitation severity was substantially alleviated, being 1+ or less in 74%, 2+ in 20%, 3+ in 4%, and 4+ in 2%; 1-year mortality was 22%. After adjustment for confounders, the logarithmic transformation (Ln) of EROA/LVEDV was associated with 1-year mortality (odds ratio 0.600, 95% confidence interval 0.386 to 0.933, p = 0.023). A higher Society of Thoracic Surgeons risk score was also associated with increased mortality. In conclusion, lower values of Ln(EROA/LVEDV) were associated with increased 1-year mortality in this multicenter registry. The slope of the association is steep at low values but gradually flattens as Ln(EROA/LVEDV) increases.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Male , Female , Mitral Valve Insufficiency/epidemiology , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Treatment Outcome , Registries , North America
13.
JACC Cardiovasc Interv ; 16(2): 168-176, 2023 01 23.
Article in English | MEDLINE | ID: mdl-36697152

ABSTRACT

BACKGROUND: The 30-day rate of stroke after transcatheter aortic valve replacement (TAVR) has been suggested as a hospital quality metric. Thirty-day stroke rates for nonsurgical, high, and moderate-risk TAVR trials were 3.4% to 6.1%, whereas those in the national Transcatheter Valve Therapy (TVT) Registry for the same patient population were much lower. Hospital comprehensive stroke center (CSC) is the highest designation for integrated acute stroke recognition, management, and care. OBJECTIVES: Using Michigan TVT data, we assessed whether in-hospital post-TAVR stroke rates varied between CSC and non-CSC institutions. METHODS: TVT data submitted from the 22 Michigan Transcatheter Aortic Valve Replacement Collaborative participating institutions between January 1, 2016, and June 30, 2019, were included (N = 6,231). Bayesian hierarchical regression models accounting for patient clinical characteristics and hospital clustering were fitted to assess the association between hospital CSC accreditation and in-hospital post-TAVR stroke. Adjusted ORs and 95% credible intervals were estimated. The University of Michigan Institutional Review Board has waived the need for the approval of studies based on the data collected by the Blue Cross Blue Shield of Michigan Cardiovascular Consortium registry. RESULTS: There were 3,882 (62.3%) patients at 9 CSC sites and 2,349 (37.7%) patients at 13 non-CSC sites. CSC sites had significantly higher rates of in-hospital post-TAVR stroke (CSC: 2.65% vs non-CSC: 1.15%; P < 0.001). After adjustment, patients who underwent TAVR at a CSC hospital had a significantly higher risk of in-hospital stroke (adjusted OR: 2.21; 95% CI: 1.03-4.62). However, CSC designation was not significantly associated with other important post-TAVR clinical outcomes including 30-day mortality. CONCLUSIONS: Reported Michigan Transcatheter Aortic Valve Replacement Collaborative TVT stroke rates were significantly higher at sites with Joint Hospital Commission stroke designation status; however, other reported important clinical outcomes did not differ significantly based on this designation. CSC designation is a possible factor in stroke rate detection differences between TAVR institutions and might be a factor in the observed differences in stroke rates between TAVR trials and those reported in TVT. In addition, these data suggest that comparison between hospitals based on post-TAVR stroke rates is potentially problematic.


Subject(s)
Aortic Valve Stenosis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/epidemiology , Michigan/epidemiology , Bayes Theorem , Treatment Outcome , Stroke/diagnosis , Stroke/epidemiology , Hospitals , Registries , Risk Factors , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
14.
JACC Cardiovasc Interv ; 16(8): 942-953, 2023 04 24.
Article in English | MEDLINE | ID: mdl-37100557

ABSTRACT

BACKGROUND: Aortic stenosis treatment should consider risks and benefits for lifetime management. Although the feasibility of redo transcatheter aortic valve replacement (TAVR) remains unclear, concerns are emerging regarding reoperation after TAVR. OBJECTIVES: The authors sought to define comparative risk of surgical aortic valve replacement (SAVR) after prior TAVR or SAVR. METHODS: Data on patients undergoing bioprosthetic SAVR after TAVR and/or SAVR were extracted from the Society of Thoracic Surgeons Database (2011-2021). Overall and isolated SAVR cohorts were analyzed. The primary outcome was operative mortality. Risk adjustment using hierarchical logistic regression as well as propensity score matching for isolated SAVR cases were performed. RESULTS: Of 31,106 SAVR patients, 1,126 had prior TAVR (TAVR-SAVR), 674 had prior SAVR and TAVR (SAVR-TAVR-SAVR), and 29,306 had prior SAVR (SAVR-SAVR). Yearly rates of TAVR-SAVR and SAVR-TAVR-SAVR increased over time, whereas SAVR-SAVR was stable. The TAVR-SAVR patients were older, with higher acuity, and with greater comorbidities than other cohorts. The unadjusted operative mortality was highest in the TAVR-SAVR group (17% vs 12% vs 9%, respectively; P < 0.001). Compared with SAVR-SAVR, risk-adjusted operative mortality was significantly higher for TAVR-SAVR (OR: 1.53; P = 0.004), but not SAVR-TAVR-SAVR (OR: 1.02; P = 0.927). After propensity score matching, operative mortality of isolated SAVR was 1.74 times higher for TAVR-SAVR than SAVR-SAVR patients (P = 0.020). CONCLUSIONS: The number of post-TAVR reoperations is increasing and represent a high-risk population. Yet even in isolated SAVR cases, SAVR after TAVR is independently associated with increased risk of mortality. Patients with life expectancy beyond a TAVR valve and unsuitable anatomy for redo-TAVR should consider a SAVR-first approach.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Risk Assessment , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Risk Factors
15.
J Thorac Cardiovasc Surg ; 165(6): 2011-2020.e5, 2023 06.
Article in English | MEDLINE | ID: mdl-34538638

ABSTRACT

BACKGROUND: Despite the rapid adoption of transcatheter aortic valve replacement since its approval, the frequency and outcomes of aortic valve reintervention after transcatheter aortic valve replacement are poorly understood. METHODS: Valve reinterventions, either surgical transcatheter aortic valve explantation or repeat transcatheter aortic valve replacement, between 2012 and 2019 were queried using the Society of Thoracic Surgeons Database and the Transcatheter Valve Therapy Registry through the Michigan Statewide quality collaborative. The reintervention frequency and clinical outcomes including observed-to-expected mortality ratio using Society of Thoracic Surgeons Predicted Risk of Mortality were reviewed. RESULTS: Among 9694 transcatheter aortic valve replacement recipients, a total of 87 patients (0.90%) received a reintervention, consisting of 34 transcatheter aortic valve explants and 53 repeat transcatheter aortic valve replacement procedures. The transcatheter aortic valve explant group demonstrated a higher Society of Thoracic Surgeons Predicted Risk of Mortality. Reintervention cases increased from 0 in 2012 and 2013 to 26 in 2019. The proportion of transcatheter aortic valve explants among all reinterventions increased and was 65% in 2019. Self-expandable devices had a higher reintervention rate than balloon-expandable devices secondary to a higher transcatheter aortic valve explant frequency (0.58% [23/3957] vs 0.19% [11/5737]; P = .001), whereas repeat transcatheter aortic valve replacement rates were similar (0.61% [24/3957] vs 0.51% [29/5737]; P = .51). Among patients with transcatheter aortic valve explants, contraindications to repeat transcatheter aortic valve replacement included unfavorable anatomy (75%), need for other cardiac surgery (29%), other structural issues by transcatheter aortic valve device (18%), and endocarditis (12%). For transcatheter aortic valve explant and repeat transcatheter aortic valve replacement, the 30-day mortality was 15% and 2% (P = .032) and the observed-to-expected mortality ratio was 1.8 and 0.3 (P = .018), respectively. CONCLUSIONS: Aortic valve reintervention remains rare but is increasing. The clinical impact of surgical device explantation was substantial, and the proportion of transcatheter aortic valve explants was significantly higher in patients with a self-expandable device.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Treatment Outcome , Prosthesis Design , Risk Factors
16.
JACC Adv ; 2(8): 100581, 2023 Oct.
Article in English | MEDLINE | ID: mdl-38938330

ABSTRACT

Background: Cardiac rehabilitation (CR) is strongly recommended for a spectrum of cardiovascular conditions and procedures including aortic valve replacement. Objectives: The purpose of this study was to characterize patient and hospital factors associated with CR participation after transcatheter aortic valve replacement (TAVR) and determine which factors explain hospital-level variation in CR participation. Methods: We linked clinical and administrative claims data from patients who underwent TAVR at 24 Michigan hospitals between January 1, 2016 and June 30, 2020 and obtained rates of CR enrollment within 90 days of discharge. Sequential mixed models were fit to evaluate hospital variation in 90-day post-TAVR CR participation. Results: Among 3,372 patients, 30.6% participated in CR within 90-days after discharge. Several patient factors were negatively associated with CR participation after TAVR including older age, Medicaid insurance, atrial fibrillation/flutter, dialysis use, and slower baseline 5-m walk times. There was substantial hospital variation in CR participation after TAVR ranging from 5% to 60% across 24 hospitals. Patient case mix did not explain hospital variation in CR across hospitals with median OR numerically increasing from 2.11 (95% CI: 1.62-2.67) to 2.13 (95% CI: 1.61-2.68) after accounting for patient-level factors. Conclusions: Less than 1 in 3 patients who underwent TAVR in Michigan participated in CR within 90-days of discharge. Although several patient factors are associated with CR participation, hospital-level variation in CR participation after TAVR is not explained by patient case mix. Identifying hospital processes of care that promote CR participation after TAVR will be critical to improving CR participation after TAVR.

17.
JACC Cardiovasc Interv ; 16(5): 558-570, 2023 03 13.
Article in English | MEDLINE | ID: mdl-36922042

ABSTRACT

BACKGROUND: Procedural success and clinical outcomes after transcatheter aortic valve replacement (TAVR) have improved, but residual aortic regurgitation (AR) and new permanent pacemaker implantation (PPI) rates remain variable because of a lack of uniform periprocedural management and implantation. OBJECTIVES: The Optimize PRO study evaluates valve performance and procedural outcomes using an "optimized" TAVR care pathway and the cusp overlap technique (COT) in patients receiving the Evolut PRO/PRO+ (Medtronic) self-expanding valves. METHODS: Optimize PRO, a nonrandomized, prospective, postmarket study conducted in the United States, Canada, Europe, Middle East, and Australia, is enrolling patients with severe symptomatic aortic stenosis and no pre-existing pacemaker. Sites follow a standardized TAVR care pathway, including early discharge and a conduction disturbance management algorithm, and transfemoral deployment using the COT. RESULTS: A total of 400 attempted implants from the United States and Canada comprised the main cohort of this second interim analysis. The mean age was 78.7 ± 6.6 years, and the mean Society of Thoracic Surgeons predictive risk of mortality was 3.0 ± 2.4. The median length of stay was 1 day. There were no instances of moderate or severe AR at discharge. At 30 days, all-cause mortality or stroke was 3.8%, all-cause mortality was 0.8%, disabling stroke was 0.7%, hospital readmission was 10.1%, and cardiovascular rehospitalization was 6.1%. The new PPI rate was 9.8%, 5.8% with 4-step COT compliance. In the multivariable model, right bundle branch block and the depth of the implant increased the risk of PPI, whereas using the 4-step COT lowered 30-day PPI. CONCLUSIONS: The use of the TAVR care pathway and COT resulted in favorable clinical outcomes with no moderate or severe AR and low PPI rates at 30 days while facilitating early discharge and reproducible outcomes across various sites and operators. (Optimize PRO; NCT04091048).


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , United States , Aged , Aged, 80 and over , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Critical Pathways , Prospective Studies , Risk Factors , Treatment Outcome , Aortic Valve Insufficiency/etiology , Heart Valve Prosthesis/adverse effects
18.
Struct Heart ; 7(3): 100164, 2023 May.
Article in English | MEDLINE | ID: mdl-37273856

ABSTRACT

Background: Cardiac computed tomography angiography was used to identify anatomical characteristics of the aortic root in patients with severe aortic regurgitation (AR) as compared to those with aortic stenosis (AS) to judge feasibility of transcatheter aortic valve replacement (TAVR) with the JenaValve Trilogy system. Methods: Cardiac computed tomography angiography was performed prior to planned TAVR for 107 patients with severe AR and 92 patients with severe AS. Measurements related to aortic root and coronary artery anatomy were obtained and compared between groups. Perimeter >90 mm and aortic annulus angle â€‹>70 degrees were defined as the theoretical exclusion criteria for TAVR. A combination of sinus of Valsalva diameter <30 mm and coronary height <12 mm was defined as high risk for coronary occlusion. Results: The mean age of patients in the AR group was 74.9 ± 11.2 years, 46% were women, and the mean Society of Thoracic Surgeons risk score for mortality was 3.6 ± 2.1. Comparatively, the mean age of patients in the AS group was 82.3 ± 5.53 years, 65% were women, and the mean Society of Thoracic Surgeonsrisk score was 5.5 ± 3.3. Annulus area, perimeter, diameter, and angle were larger in patients with severe AR. Sinus of Valsalva diameters and heights were larger in patients with severe AR. More AR patients were excluded based on perimeter (14 vs. 2%) and annulus angle (6 vs. 1%). More AS patients exhibited high-risk anatomy for left main coronary occlusion (21 vs. 7%) and right coronary occlusion (14 vs. 3%). The maximum dimension of the ascending aorta was larger in patients with severe AR (39 vs. 35 mm). The percentage of referred AR patients with significant aortopathy requiring surgical intervention was very low (only 1 AR patient with ascending aorta diameter >5.5 cm). Conclusions: A significantly larger proportion of patients with severe AR are excluded from TAVR as compared to AS due to large aortic annulus size and steep annulus angulation. By far the most prevalent excluding factor is aortic annulus size, with fewer patients excluded due to angulation. AR patients have lower-risk anatomy for coronary occlusion. Larger transcatheter valve sizes and further delivery system modifications are required to treat a larger proportion of AR patients.

19.
J Am Coll Cardiol ; 81(17): 1663-1674, 2023 05 02.
Article in English | MEDLINE | ID: mdl-36882136

ABSTRACT

BACKGROUND: Randomized data comparing outcomes of transcatheter aortic valve replacement (TAVR) with surgery in low-surgical risk patients at time points beyond 2 years is limited. This presents an unknown for physicians striving to educate patients as part of a shared decision-making process. OBJECTIVES: The authors evaluated 3-year clinical and echocardiographic outcomes from the Evolut Low Risk trial. METHODS: Low-risk patients were randomized to TAVR with a self-expanding, supra-annular valve or surgery. The primary endpoint of all-cause mortality or disabling stroke and several secondary endpoints were assessed at 3 years. RESULTS: There were 1,414 attempted implantations (730 TAVR; 684 surgery). Patients had a mean age of 74 years and 35% were women. At 3 years, the primary endpoint occurred in 7.4% of TAVR patients and 10.4% of surgery patients (HR: 0.70; 95% CI: 0.49-1.00; P = 0.051). The difference between treatment arms for all-cause mortality or disabling stroke remained broadly consistent over time: -1.8% at year 1; -2.0% at year 2; and -2.9% at year 3. The incidence of mild paravalvular regurgitation (20.3% TAVR vs 2.5% surgery) and pacemaker placement (23.2% TAVR vs 9.1% surgery; P < 0.001) were lower in the surgery group. Rates of moderate or greater paravalvular regurgitation for both groups were <1% and not significantly different. Patients who underwent TAVR had significantly improved valve hemodynamics (mean gradient 9.1 mm Hg TAVR vs 12.1 mm Hg surgery; P < 0.001) at 3 years. CONCLUSIONS: Within the Evolut Low Risk study, TAVR at 3 years showed durable benefits compared with surgery with respect to all-cause mortality or disabling stroke. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients; NCT02701283).


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Male , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Risk Factors , Treatment Outcome , Prospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Heart Valve Prosthesis/adverse effects , Stroke/epidemiology , Stroke/etiology , Stroke/surgery
20.
J Heart Valve Dis ; 21(5): 564-9, 2012 Sep.
Article in English | MEDLINE | ID: mdl-23167219

ABSTRACT

BACKGROUND AND AIM OF THE STUDY: The study aim was to determine if significant ischemic mitral regurgitation (IMR) is adequately addressed in patients undergoing multi-vessel percutaneous coronary intervention (PCI). METHODS: The cardiac catheterization laboratory database at the authors' institution was accessed over a five-year interval to identify those patients who had undergone multi-vessel PCI. Both, pre- and post-revascularization echocardiographic data were retrieved, and clinical data, MR presence and severity, and outcomes were each assessed. RESULTS: In total, 150 patients (100 males, 50 females; mean age 63 +/- 12 years) underwent PCI. Of these 150 patients, pre-procedural echocardiograms were not performed in 54 cases (35%); hence, the study group comprised 96 patients with both pre- and postprocedural echocardiograms. Of these patients, 21 (22%) had moderate or greater (2+) IMR. The severity of the IMR did not change significantly after multivessel PCI (2 +/- 0.8+ preoperatively versus 1.9 +/- 1.0+ postoperatively). CONCLUSION: Clinically significant IMR occurred not infrequently among patients treated with multivessel PCI, but the severity did not change with percutaneous revascularization, despite this being predominantly complete. In more than one-third of the patients, adequate pre-PCI echocardiography was unavailable, which suggested the possibility that not all IMR had been identified.


Subject(s)
Coronary Artery Disease/complications , Mitral Valve Insufficiency/surgery , Percutaneous Coronary Intervention , Aged , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Echocardiography , Female , Humans , Male , Middle Aged , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/diagnostic imaging , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL