Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters

Database
Language
Publication year range
1.
Sensors (Basel) ; 14(9): 16287-95, 2014 Sep 02.
Article in English | MEDLINE | ID: mdl-25184492

ABSTRACT

In this study, we investigate the keys to obtain a sensitive ammonia sensor with high air stability by using a low-cost polythiophene diode with a vertical channel and a porous top electrode. Poly(3-hexylthiophene) (P3HT) and air-stable poly(5,5'-bis(3-dodecyl-2-thienyl)-2,2'-bithiophene) (PQT-12) are both evaluated as the active sensing layer. Two-dimensional current simulation reveals that the proposed device exhibits numerous connected vertical nanometer junctions (VNJ). Due to the de-doping reaction between ammonia molecules and the bulk current flowing through the vertical channel, both PQT-12 and P3HT VNJ-diodes exhibit detection limits of 50-ppb ammonia. The P3HT VNJ-diode, however, becomes unstable after being stored in air for two days. On the contrary, the PQT-12 VNJ-diode keeps an almost unchanged response to 50-ppb ammonia after being stored in air for 25 days. The improved storage lifetime of an organic-semiconductor-based gas sensor in air is successfully demonstrated.


Subject(s)
Ammonia/analysis , Conductometry/instrumentation , Gases/analysis , Organoselenium Compounds/chemistry , Semiconductors , Thiophenes/chemistry , Equipment Design , Equipment Failure Analysis , Transducers
2.
ACS Sens ; 2(12): 1788-1795, 2017 12 22.
Article in English | MEDLINE | ID: mdl-29124925

ABSTRACT

In this work, a TFB (poly[(9,9-dioctylfluorenyl-2,7-diyl)-co-(4,4'-(N-(4-s-butylphenyl)diphenylamine)]) sensor with a cylindrical nanopore structure exhibits a high sensitivity to ammonia in ppb-regime. The lifetime and sensitivity of the TFB sensor were studied and compared to those of P3HT (poly(3-hexylthiophene)), NPB (N,N'-di(1-naphthyl)-N,N'-diphenyl-(1,1'-biphenyl)-4,4'-diamine), and TAPC (4,4'-cyclohexylidenebis[N,N-bis(4-methylphenyl) benzenamine]) sensors with the same cylindrical nanopore structures. The TFB sensor outstands the others in sensitivity and lifetime and it shows a sensing response (current variation ratio) of 13% to 100 ppb ammonia after 64 days of storage in air. A repeated sensing periods testing and a long-term measurement have also been demonstrated for the test of robustness. The performance of the TFB sensor is stable in both tests, which reveals that the TFB sensor can be utilized in our targeting clinical trials. In the last part of this work, we study the change of ammonia concentration in the breath of hemodialysis (HD) patients before and after dialysis. An obvious drop of breath ammonia concentration can be observed after dialysis. The reduction of breath ammonia is also correlated with the reduction of blood urea nitrogen (BUN). A correlation coefficient of 0.82 is achieved. The result implies that TFB sensor may be used as a real-time and low cost breath ammonia sensor for the daily tracking of hemodialysis patients.


Subject(s)
Ammonia/analysis , Breath Tests/methods , Fluorenes/chemistry , Polymers/chemistry , Renal Dialysis , Aged , Blood Urea Nitrogen , Breath Tests/instrumentation , Female , Humans , Male , Middle Aged , Nanopores
3.
ACS Sens ; 2(4): 531-539, 2017 Apr 28.
Article in English | MEDLINE | ID: mdl-28723177

ABSTRACT

In this work, we successfully demonstrate a fast method to determine the fish freshness by using a sensing system containing an ultrasensitive amine gas sensor to detect the volatile amine gas from the raw fish meat. When traditional titration method takes 4 h and complicated steps to test the total volatile basic nitrogen (TVB-N) as a worldwide standard for fish freshness, our sensor takes 1 min to deliver an electrical sensing response that is highly correlated with the TVB-N value. When detecting a fresh fish with a TVB-N as 18 mg/100 g, the sensor delivers an effective ammonia concentration as 100 ppb. For TVB-N as 28-35 mg/100 g, a well-accepted freshness limit, the effective ammonia concentration is as 200-300 ppb. The ppb-regime sensitivity of the sensor and the humidity control in the sensing system are the keys to realizing fast and accurate detection. It is expected that the results in this report enable the development of on-site freshness detection and real-time monitoring in a fish factory.

SELECTION OF CITATIONS
SEARCH DETAIL