Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Radiology ; 251(1): 58-66, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19251937

ABSTRACT

PURPOSE: To evaluate the influence of subtotal radiofrequency (RF) ablation on a tumor-specific immune response in a murine tumor model and to explore the role of intratumoral dendritic cells (ITDCs) in mediating this effect. MATERIALS AND METHODS: Animal work was performed according to an approved protocol and in compliance with the National Cancer Institute Animal Care and Use Committee guidelines and regulations. A murine urothelial carcinoma (MB49) model expressing the male minor histocompatibility (HY) antigen was inoculated subcutaneously in female mice. Fourteen days later, splenic T cells were analyzed with enzyme-linked immunosorbent spot for HY immune response (n = 57). In subsequent experiments, mice were randomized into control (n = 7), RF ablation, ITDC (n = 9), and RF ablation + ITDC (n = 9) groups and monitored for tumor growth. Eleven days after treatment, tumors were harvested for histologic and immunohistochemical analysis. Animals demonstrating complete tumor regression were rechallenged in the contralateral flank. RESULTS: Animals treated with subtotal RF ablation showed significant increases in tumor-specific class I and II responses to HY antigens and tumor regression. RF ablation, ITDC, and combined groups demonstrated similar levels of antigen-presenting cell infiltration; all groups demonstrated greater levels of infiltration compared with untreated controls. ITDC injection also resulted in tumor regression. However, combination therapy did not enhance tumor regression when compared with either treatment alone. Rechallenged mice in RF ablation, ITDC, and combination groups demonstrated significant tumor growth inhibition compared with controls. CONCLUSION: Subtotal RF ablation treatment results in enhanced systemic antitumor T-cell immune responses and tumor regression that is associated with increased dendritic cell infiltration. ITDC injection mimics the RF ablation effect but does not increase immune responses when injected immediately after RF ablation.


Subject(s)
Antigen Presentation/immunology , Antigen-Presenting Cells/immunology , Neoplasm Metastasis/immunology , Neoplasm Metastasis/prevention & control , Urinary Bladder Neoplasms/immunology , Urinary Bladder Neoplasms/surgery , Animals , Catheter Ablation , Cell Line, Tumor , Humans , Immunity, Innate , Mice , Neoplasm Metastasis/pathology , Urinary Bladder Neoplasms/pathology
2.
J Vasc Interv Radiol ; 17(12): 1999-2004, 2006 Dec.
Article in English | MEDLINE | ID: mdl-17185699

ABSTRACT

PURPOSE: High-radiation exposure occurs during computed tomographic (CT) fluoroscopy. Patient and operator doses during thoracic and abdominal interventional procedures were studied in the present experiment, and a novel shielding device to reduce exposure to the patient and operator was evaluated. MATERIALS AND METHODS: With a 16-slice CT scanner in CT fluoroscopy mode (120 kVp, 30 mA), surface dosimetry was performed on adult and pediatric phantoms. The shielding was composed of tungsten antimony in the form of a lightweight polymer sheet. Doses to the patient were measured with and without shielding for thoracic and abdominal procedures. Doses to the operator were recorded with and without phantom, gantry, and table shielding in place. Double-layer lead-free gloves were used by the operator during the procedures. RESULTS: Tungsten antimony shielding adjacent to the scan plane resulted in a maximum dose reduction of 92.3% to the patient. Maximum 85.6%, 93.3%, and 85.1% dose reductions were observed for the operator's torso, gonads, and hands, respectively. The use of double-layer lead-free gloves resulted in a maximum radiation dose reduction of 97%. CONCLUSIONS: Methods to reduce exposure during CT fluoroscopy are effective and should be searched for. Significant reduction in radiation doses to the patient and operator can be accomplished with tungsten antimony shielding.


Subject(s)
Fluoroscopy , Radiation Injuries/prevention & control , Radiation Protection/instrumentation , Radiography, Interventional , Antimony , Gloves, Protective , Humans , Occupational Exposure/prevention & control , Phantoms, Imaging , Radiation Dosage , Scattering, Radiation , Tomography, X-Ray Computed , Tungsten
SELECTION OF CITATIONS
SEARCH DETAIL