Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 34
Filter
1.
Transfusion ; 64(3): 546-549, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38230511

ABSTRACT

BACKGROUND: Blood donation is a safe process though reactions may still occur. We describe a rare vascular complication in a frequent donor, with improvements in the collection process aimed at avoiding future events. METHODS: A 63-year-old woman presented with local pain and an apparent collection in the left arm 8 days after donation. Duplex ultrasound identified a superficial liquid collection and signs of arteriovenous fistula (AVF) between the cubital vein and an arterial branch. A computed tomography (CT)-angio performed 1 day after ultrasound did not identify signs of AVF, followed by a new duplex which confirmed CT-angio findings. It was assumed that a traumatic AVF evolved with spontaneous thrombosis. In the early follow-up (18 days), a progressive regression of hematoma was observed without any sequelae. RESULTS: Investigation showed a faster whole blood bag collection time (3 min; normal: 5-9 min), and the processed packed red blood cell had a brighter red color than usual. The donor reported local bleeding after needle withdrawal, not observed in previous donations and a bruise forming on the same day. No arterial puncture (AP) was noticed by the collection staff during the procedure. The staff was retrained and actions were taken focusing on more active surveillance of late reactions, highlighting the importance of post-donation information by the donors, regardless of any adverse reaction observed, to detect late complications. CONCLUSION: We described an uncommon AP in a donor that was not identified, leading to an AVF that spontaneously thrombosed.


Subject(s)
Blood Component Removal , Vascular System Injuries , Female , Humans , Middle Aged , Blood Donors , Blood Donation , Punctures
2.
Transfusion ; 62(8): 1559-1570, 2022 08.
Article in English | MEDLINE | ID: mdl-35808950

ABSTRACT

BACKGROUND: At the start of the coronavirus disease 2019 (COVID-19) pandemic, widespread blood shortages were anticipated. We sought to determine how hospital blood supply and blood utilization were affected by the first wave of COVID-19. STUDY DESIGN AND METHODS: Weekly red blood cell (RBC) and platelet (PLT) inventory, transfusion, and outdate data were collected from 13 institutions in the United States, Brazil, Canada, and Denmark from March 1st to December 31st of 2020 and 2019. Data from the sites were aligned based on each site's local first peak of COVID-19 cases, and data from 2020 (pandemic year) were compared with data from the corresponding period in 2019 (pre-pandemic baseline). RESULTS: RBC inventories were 3% lower in 2020 than in 2019 (680 vs. 704, p < .001) and 5% fewer RBCs were transfused per week compared to 2019 (477 vs. 501, p < .001). However, during the first COVID-19 peak, RBC and PLT inventories were higher than normal, as reflected by deviation from par, days on hand, and percent outdated. At this time, 16% fewer inpatient beds were occupied, and 43% fewer surgeries were performed compared to 2019 (p < .001). In contrast to 2019 when there was no correlation, there was, in 2020, significant negative correlations between RBC and PLT days on hand and both percentage occupancy of inpatient beds and percentage of surgeries performed. CONCLUSION: During the COVID-19 pandemic in 2020, RBC and PLT inventories remained adequate. During the first wave of cases, significant decreases in patient care activities were associated with excess RBC and PLT supplies and increased product outdating.


Subject(s)
COVID-19 , Pandemics , COVID-19/epidemiology , Erythrocyte Transfusion , Erythrocytes , Hospitals , Humans , United States
3.
Transfusion ; 61(5): 1447-1460, 2021 05.
Article in English | MEDLINE | ID: mdl-33604884

ABSTRACT

INTRODUCTION: Little is known about the neutralizing (nAb) and binding antibody kinetics in COVID-19 convalescent plasma donors, especially during the first 100 days after disease onset. MATERIALS AND METHODS: A cohort of previously RT-PCR positive (detected by nasopharyngeal swab during the acute phase), male convalescent patients, all with mild symptoms, were enrolled in serial blood sample collection for a longitudinal nAb titers and anti-nucleocapsid (NP) antibodies (IgM, IgG and IgA) evaluation. NAbs were detected by a cytopathic effect-based virus neutralization test (CPE-based VNT), carried out with SARS-CoV-2 (GenBank: MT350282). RESULTS: A total of 78 male volunteers provided 316 samples, spanning a total of 4820 days of study. Although only 25% of donors kept nAb titers ≥160 within 100 days after the onset of disease, there was >75% probability of sustaining nAb titers ≥160 in volunteers whose initial nAb titer was ≥1280, weight ≥ 90 kg or obese, according to their body mass index (BMI), as evidenced by Kaplan-Meier analysis and Cox hazard regression (all p < .02). There was no correlation between the ABO group, ABO antibody titers and persistent high nAb titers. High IgG anti-NP (S/CO ≥5.0) is a good surrogate for detecting nAb ≥ 160, defined by the ROC curve (sensitivity = 90.5%; CI95%: 84.5%-94.7%). CONCLUSION: Selection of CCP donors for multiple collections based on initial high nAb titers (≥1280) or BMI ≥ 30 kg/m2 provides a simple strategy to achieve higher quality in CCP programs. High IgG anti-NP levels can also be used as surrogate markers for high nAb screening.


Subject(s)
ABO Blood-Group System/blood , Antibodies, Neutralizing/blood , Antibodies, Viral/blood , Blood Donors , Blood Safety , Body Mass Index , COVID-19/blood , Nucleocapsid/blood , SARS-CoV-2/metabolism , Adolescent , Adult , Female , Humans , Kinetics , Longitudinal Studies , Male , Middle Aged
4.
Transfusion ; 61(12): 3455-3467, 2021 12.
Article in English | MEDLINE | ID: mdl-34674284

ABSTRACT

BACKGROUND: COVID-19 high-titer CCP selection is a concern, because neutralizing antibody (nAb) testing requires sophisticated labs and methods. Surrogate tests are an alternative for measuring nAb levels in plasma bags, including those that are pathogen-reduced. STUDY DESIGN/METHODS: We studied a panel consisting of 191 samples from convalescent donors tested by nAb (CPE-VNT), obtained from 180 CCP donations (collection: March 20-January 21) and 11 negative controls, with a total of 80 and 111 serum and plasma samples (71 amotosalen/UV treated), with nAb titers ranging from negative to 10,240. Samples were blindly tested for several surrogates: one anti-RBD, two anti-spike, and four anti-nucleocapsid tests, either isolated or combined to improve their positive predictive values as predictors of the presence of high-titer nAbs, defined as those with titers ≥160. RESULTS: Except for combined and anti-IgA/M tests, all isolated surrogate tests showed excellent performance for nAb detection: sensitivity (98.3%-100%), specificity (85.7%-100%), PPV (98.9%-100%), NPV (81.3%-100%), and AUC (0.93-0.96), with a variable decrease in sensitivity and considerably lower specificity when using FDA authorization and concomitant nAb titers ≥160. All surrogates had AUCs that were statistically different from CPE-VNT if nAb≥160, including when using combined, orthogonal approaches. CONCLUSIONS: Surrogate tests (isolated or in combination) have an indirect good performance in detecting the presence of nAb, with lower sensitivity and specificity when high nAb titer samples are used, possibly accepting a considerable number of donors whose nAb titers are actually low, which should be evaluated by each laboratory responsible for CCP collection.


Subject(s)
Antibodies, Neutralizing/therapeutic use , Antibodies, Viral/therapeutic use , COVID-19/therapy , Blood Donors , Humans , Immunization, Passive , SARS-CoV-2 , COVID-19 Serotherapy
5.
Transfusion ; 61(8): 2295-2306, 2021 08.
Article in English | MEDLINE | ID: mdl-34173248

ABSTRACT

BACKGROUND: Current evidence regarding COVID-19 convalescent plasma (CCP) transfusion practices is limited and heterogeneous. We aimed to determine the impact of the use of CCP transfusion in patients with previous circulating neutralizing antibodies (nAbs) in COVID-19. METHODS: Prospective cohort including 102 patients with COVID-19 transfused with ABO compatible CCP on days 0-2 after enrollment. Clinical status of patients was assessed using the adapted World Health Organization (WHO) ordinal scale on days 0, 5, and 14. The nAbs titration was performed using the cytopathic effect-based virus neutralization test with SARS-CoV-2 (GenBank MT126808.1). The primary outcome was clinical improvement on day 14, defined as a reduction of at least two points on the adapted WHO ordinal scale. Secondary outcomes were the number of intensive care unit (ICU)-free days and the number of invasive mechanical ventilation-free days. RESULTS: Both nAbs of CCP units transfused (p < 0.001) and nAbs of patients before CCP transfusions (p = 0.028) were associated with clinical improvements by day 14. No significant associations between nAbs of patients or CCP units transfused were observed in the number of ICU or mechanical ventilation-free days. Administration of CCP units after 10 days of symptom onset resulted in a decrease in ICU-free days (p < 0.001) and mechanical ventilation-free days (p < 0.001). CONCLUSION: Transfusion of high titer nAbs CCP units may be a determinant in clinical strategies against COVID-19. We consider these data as useful parameters to guide future CCP transfusion practices.


Subject(s)
Antibodies, Neutralizing/blood , COVID-19/therapy , Adult , Aged , Aged, 80 and over , Antibodies, Neutralizing/immunology , Antibodies, Viral/blood , Antibodies, Viral/immunology , Blood Donors , COVID-19/blood , COVID-19/immunology , Cohort Studies , Female , Humans , Immunization, Passive/methods , Male , Middle Aged , SARS-CoV-2/immunology , COVID-19 Serotherapy
6.
Vox Sang ; 116(5): 557-563, 2021 May.
Article in English | MEDLINE | ID: mdl-33650690

ABSTRACT

BACKGROUND: Blood groups and anti-A isohemagglutinin may be involved in susceptibility to SARS-CoV-2 infection. MATERIALS AND METHODS: We retrospectively studied 268 COVID-19 convalescent plasma donors and 162 COVID-19 inpatients (total 430 subjects, confirmed by RT-PCR) and 2,212 healthy volunteer first-time blood donors as a control group. These were further divided into two groups: those with anti-A (blood types O and B) and those without it (types A and AB). Titres of nucleoproteins, and neutralizing SARS-CoV-2 antibody were measured in the convalescent plasma donors and inpatients. Multivariate logistic regression and non-parametric tests were applied. RESULTS: Persons having types O or B showed less infection prevalence than those of types A or AB (OR = 0·62, 95% CI 0·50-0·78; P < 0·001), but there was no difference when COVID-19 inpatients were analysed. Immunoglobulins M, G and A were lower in COVID-19 subjects of types O or B group than those of A or AB (0·16 vs. 0·19; P = 0·03, 2·11 vs. 2·55; P = 0·02, 0·23 vs. 0·32; P = 0·03, respectively). CONCLUSION: In this retrospective cohort, COVID-19 individuals were less likely to belong to blood types O and B, and also had lower SARS-CoV-2 antibody titres than A and AB individuals. COVID-19 severity did not associate with the blood groups.


Subject(s)
ABO Blood-Group System/blood , Antibodies, Viral/blood , COVID-19/blood , COVID-19/therapy , Adult , Antibodies, Neutralizing/blood , Antibodies, Neutralizing/immunology , Antibodies, Viral/immunology , COVID-19/immunology , Hemagglutinins/immunology , Humans , Immunization, Passive , Male , Middle Aged , SARS-CoV-2/immunology , COVID-19 Serotherapy
7.
Transfusion ; 60(12): 2938-2951, 2020 12.
Article in English | MEDLINE | ID: mdl-32935877

ABSTRACT

BACKGROUND: Coronavirus disease 2019 (COVID-19) convalescent plasma (CCP) collection began in two Brazilian hospitals for treatment of severe/critical patients. METHODS AND MATERIALS: Mild/moderate COVID-19 convalescents were selected as CCP donors after reverse transcription polymerase chain reaction (RT-PCR) confirmed severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection and absence of symptoms for ≥14 days plus (a) age (18-60 years), body weight greater than 55 kg; (b) immunohematological studies; (c) no infectious markers of hepatitis B virus, hepatitis C virus, human immunodeficiency virus, human T-lymphotropic virus-1/2, Chagas and syphilis infection; (d) no HLA antibodies (multiparous); (e) second RT-PCR (nasopharyngeal swab and/or blood) negativity; (f) virus neutralization test (cytopathic effect-based virus neutralization test neutralizing antibody) and anti-nucleocapsid protein SARS-CoV-2 IgM, IgG, and IgA enzyme-linked immunosorbent assays. RESULTS: Among 271 donors (41 females, 230 males), 250 presented with neutralizing antibodies. Final RT-PCR was negative on swab (77.0%) or blood (88.4%; P = .46). Final definition of RT-PCR was only defined at more than 28 days after full recovery in 59 of 174 (33.9%) RT-PCR -ve, and 25/69 RT-PCR +ve (36.2%; 13 between 35 and 48 days). Neutralizing antibody titers of 160 or greater were found in 63.6%. Correlation between IgG signal/cutoff of 5.0 or greater and neutralizing antibody of 160 or greater was 82.4%. Combination of final RT-PCR -ve with neutralizing antibody ≥160 was 41.3% (112/271). Serial plasma collection showed decline in neutralizing antibody titers and IgA levels (P < .05), probably denoting a "golden period" for CCP collection (≤28 days after joining the program); IgA might have an important role as neutralizing antibody. Donor's weight, days between disease onset and serial plasma collection, and IgG and IgM levels are important predictors for neutralizing antibody titer. CONCLUSIONS: RT-PCR +ve cases are still detected in 36.2% within 28 to 48 days after recovery. High anti-nucleocapsid protein IgG levels may be used as a surrogate marker to neutralizing antibody.


Subject(s)
Antibodies, Neutralizing/blood , Antibodies, Viral/blood , COVID-19 Serological Testing , COVID-19/blood , COVID-19/therapy , Convalescence , Donor Selection/statistics & numerical data , SARS-CoV-2/immunology , Adult , Blood Donors , Brazil/epidemiology , COVID-19/immunology , COVID-19 Nucleic Acid Testing , Enzyme-Linked Immunosorbent Assay , Female , Humans , Immunization, Passive , Immunoglobulin A/blood , Immunoglobulin G/blood , Immunoglobulin M/blood , Male , Middle Aged , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2/isolation & purification , Time Factors , Young Adult , COVID-19 Serotherapy
8.
Transfus Apher Sci ; 59(5): 102865, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32646794

ABSTRACT

OBJECTIVES: This study aimed to evaluate the reactivity and the titers of commercial anti-A and anti-A,B antisera in the detection of A weak antigen expression in human red blood cells. BACKGROUND: Commercial monoclonal antisera for ABO phenotyping are useful reagents allowing the identification of the four main ABO phenotypes (A, B, AB, and O). However, the reactivity of these commercial reagents can not be evident when the A or B antigens are weakly expressed, and these antisera have low titers. METHODS/MATERIALS: Six samples from blood donors and five samples from patients with ABO forward and reverse discrepant phenotyping were evaluated. The ABO phenotyping was carried out with different commercial monoclonal anti-A and anti-A,B antisera under different temperatures, using test tubes and gel column agglutination. RESULTS: Monoclonal anti-A antisera with titers less than 256 and anti-A,B with titers less than 128 failed to detect the weak expression of A antigen in 73% and 67% of the A weak phenotypes, respectively. Titres equal to or higher than 2048 (anti-A) and 1024 (anti-A,B) showed better reactivity, independent of the cell clone. CONCLUSION: Our data indicate that anti-A and anti-A,B antisera with high titers give better reactivity with red blood cells carrying A weak antigen expression.


Subject(s)
ABO Blood-Group System/genetics , Antibodies/genetics , Female , Humans , Male , Phenotype
9.
Transfus Med Hemother ; 46(4): 276-281, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31700510

ABSTRACT

Twin hematopoietic chimera in humans is a phenomenon that was discovered accidentally and the prevalence of which remains unclear. The resolution of chimera cases requires studying family medical records, data analysis, and investigations of hematopoietic cells and cells from other tissues. The interactions among ABO, Lewis, and secretor histo-blood group systems are explored to resolve cases of hematopoietic chimera. Here we report a rare case of hematopoietic chimera where twins present a mixed field reaction in the ABO, Rh, and Kidd red blood cell phenotyping. Using red blood cells separated from the mixed field as well as molecular approaches and investigations of family members, we identify inconsistent genotypes with the Mendelian inheritance pattern when comparing the peripheral blood with the buccal epithelium of the male twin and his twin sister. Analysis of the ABO, Lewis, and secretor phenotypes, and genomic DNA from buccal epithelium showed the genotypes ABO*A1.01/ABO*B.01 and FUT2*01N.02/ FUT2*01N.02 in the male twin and the genotypes ABO*O.01.01/ABO*O.01.02 and FUT2*01/FUT2*01 in the female twin. The results of the HLA-DRB1 genotyping showed inconsistency between the male and his twin sister. We conclude that the serological analyses combined with molecular approaches used in this study are good tools to resolve cases of hematopoietic chimera.

SELECTION OF CITATIONS
SEARCH DETAIL