Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
J Nucl Cardiol ; 30(1): 116-126, 2023 02.
Article in English | MEDLINE | ID: mdl-35610536

ABSTRACT

PURPOSE: Evaluate the prediction of quantitative coronary angiography (QCA) values from MPI, by means of deep learning. METHODS: 546 patients (67% men) undergoing stress 99mTc-tetrofosmin MPI in a CZT camera in the upright and supine position were included (1092 MPIs). Patients were divided into two groups: ICA group included 271 patients who performed an ICA within 6 months of MPI and a control group with 275 patients with low pre-test probability for CAD and a normal MPI. QCA analyses were performed using radiologic software and verified by an expert reader. Left ventricular myocardium was segmented using clinical nuclear cardiology software and verified by an expert reader. A deep learning model was trained using a double cross-validation scheme such that all data could be used as test data as well. RESULTS: Area under the receiver-operating characteristic curve for the prediction of QCA, with > 50% narrowing of the artery, by deep learning for the external test cohort: per patient 85% [95% confidence interval (CI) 84%-87%] and per vessel; LAD 74% (CI 72%-76%), RCA 85% (CI 83%-86%), LCx 81% (CI 78%-84%), and average 80% (CI 77%-83%). CONCLUSION: Deep learning can predict the presence of different QCA percentages of coronary artery stenosis from MPIs.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Deep Learning , Myocardial Perfusion Imaging , Male , Humans , Female , Coronary Angiography/methods , Tomography, Emission-Computed, Single-Photon/methods , Myocardial Perfusion Imaging/methods , Perfusion , Cadmium , Tellurium
2.
Article in English | MEDLINE | ID: mdl-37748688

ABSTRACT

PURPOSE: To evaluate the diagnostic performance of a novel deep learning attenuation correction software (DLACS) for myocardial perfusion imaging (MPI) using a cadmium-zinc-telluride (CZT) cardio dedicated camera with invasive coronary angiography (ICA) correlation for the diagnosis of coronary artery disease (CAD) in a high-risk population. METHODS: Retrospective study of 300 patients (196 males [65%], mean age 68 years) from September 2014 to October 2019 undergoing MPI, followed by ICA and evaluated by means of quantitative angiography software, within six months after the MPI. The mean pre-test probability score for coronary disease according to the European Society of Cardiology criteria was 37% for the whole cohort. The MPI was performed in a dedicated CZT cardio camera (D-SPECT Spectrum Dynamics) with a two-day protocol, according to the European Association of Nuclear Medicine guidelines. MPI was retrospectively evaluated with and without the DLACS. RESULTS: The overall diagnostic accuracy of MPI without DLACS to identify patients with any obstructive CAD at ICA was 87%, sensitivity 94%, specificity 57%, Positive Predictive Value 91% and Negative Predictive Value 64%. Using DLACS the overall diagnostic accuracy was 90%, sensitivity 91%, specificity 86%, Positive Predictive Value 97% and Negative Predictive Value 66%. CONCLUSION: Use of the novel DLACS enhances performance of the MPI using the CZT D-SPECT camera and achieves improved results, especially avoiding artefacts and reducing the number of false positive results.


Subject(s)
Cadmium , Coronary Artery Disease , Deep Learning , Myocardial Perfusion Imaging , Tellurium , Zinc , Male , Humans , Aged , Retrospective Studies , Coronary Angiography/methods , Myocardial Perfusion Imaging/methods , Coronary Artery Disease/diagnostic imaging
3.
Article in English | MEDLINE | ID: mdl-36103979

ABSTRACT

PURPOSE: To evaluate the diagnostic performance of three different cardiac stress protocols for myocardial perfusion imaging (MPI) using a cadmium-zinc-telluride (CZT) camera with invasive coronary angiography (ICA) correlation for the diagnosis of coronary artery disease in a high risk population. METHODS: Retrospective study of 263 patients (96 women and 167 males, mean age 68 years) from which 119 patients performed a bicycle stress test (BST), 113 pharmacological stress test (PST) and 31 a combination of the two (CST) between September 2014 and December 2018. The patients then underwent myocardial perfusion imaging (MPI), followed by ICA and evaluated by means of quantitative angiography software, within six months after the MPI. The mean pre-test probability score for coronary disease according to the European Society of Cardiology criteria was 36% for the whole population. The MPI was performed in a dedicated CZT cardio camera (D-SPECT Spectrum Dynamics) with a two-day protocol, according to the European Association of Nuclear Medicine guidelines. RESULTS: No significant difference was observed between the three stress protocols in terms of diagnostic accuracy (BST 85%, PST 88%, CST 84%). The overall diagnostic accuracy of MPI to identify patients with any obstructive CAD at ICA was 86%, Sensitivity 93%, Specificity 54%, PPV 90% and NPV 63%. CONCLUSION: The CZT D-SPECT camera achieves overall satisfactory results in the diagnosis of CAD, observing no significant differences in the diagnostic performance when the stress test was performed as a BST, PST or CST.

SELECTION OF CITATIONS
SEARCH DETAIL