Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Oper Dent ; 37(2): 188-94, 2012.
Article in English | MEDLINE | ID: mdl-22166106

ABSTRACT

The aim of this study was to assess Knoop hardness at different depths of a dual-cured self-adhesive resin cement through different thicknesses of Empress Esthetic® ceramic.Flattened bovine dentin was embedded in resin. The cement was inserted into a rubber mold (0.8 x 5 mm) that was placed between two polyvinyl chloride plastic films and placed over the flat dentin and light cured by Elipar Trilight-QTH (800 mW/cm2) or Ultra-Lumelight-emitting diode (LED 5; 1585 mW/cm2) over ceramic disks 1.4 or 2 mm thick. The specimens(n=6) were stored for 24 hours before Knoop hardness (KHN) was measured. The data were submitted to analysis of variance in a factorial split-plot design and Tukey's test (a=0.05).There was significant interaction among the study factors. In the groups cured by the QTHunit, an increase in ceramic thickness resulted in reduced cement hardness values at all depths, with the highest values always being found in the center (1.4 mm, 58.1; 2 mm, 50.1)and the lowest values at the bottom (1.4 mm,23.8; 2 mm, 20.2). When using the LED unit, the hardness values diminished with increased ceramic thickness only on the top (1.4 mm,51.5; 2 mm, 42.3). In the group with the 1.4-mm-thick disk, the LED curing unit resulted in similar values on the top (51.5) and center(51.9) and lower values on the bottom (24.2).However, when the cement was light cured through the 2-mm disk, the highest hardness value was obtained in the center (51.8), followed by the top (42.3) and bottom (19.9),results similar to those obtained with the QTH curing unit (center > top > bottom). The hardness values of the studied cement at different depths were dependent on the ceramic thickness but not on the light curing units used.


Subject(s)
Resin Cements/chemistry , Aluminum Silicates/chemistry , Animals , Cattle , Curing Lights, Dental/classification , Dental Porcelain/chemistry , Dentin/ultrastructure , Dentin-Bonding Agents/chemistry , Hardness , Light-Curing of Dental Adhesives/methods , Materials Testing , Plastics/chemistry , Polymerization , Polyvinyl Chloride/chemistry , Surface Properties , Temperature , Time Factors
2.
Oper Dent ; 36(6): 670-7, 2011.
Article in English | MEDLINE | ID: mdl-21913859

ABSTRACT

The purpose of this study was to evaluate the biomechanical degradation of two nanofilled restorative materials (a resin-modified glass ionomer, Ketac N100 and a composite, Filtek Z350), compared with conventional materials (Vitremer and TPH Spectrum). Twenty specimens obtained from each material were divided into two storage groups (n=10): relative humidity (control) and Streptococcus mutans biofilm (biodegradation). After 7 days of storage, roughness values (Ra) and micrographs by scanning electron microscopy (SEM) were obtained. In a second experimental phase, the specimens previously subjected to biodegradation were fixed to the tooth-brushing device and abraded via toothbrushes, using dentifrice slurry (mechanical degradation). Next, these specimens were washed, dried, and reassessed by roughness and SEM. The data were submitted to repeated measures three-way analysis of variance (ANOVA) and Tukey tests (p<0.05). There was statistically significant interaction among factors: material, storage (humidity/biofilm), and abrasion (before/after). After biodegradation (S mutans biofilm storage), Ketac N100 presented the highest Ra values. Concerning bio plus mechanical challenge, TPH Spectrum, Ketac N100, and Vitremer presented the undesirable roughening of their surfaces, while the nano composite Filtek Z350 exhibited the best resistance to cumulative challenges proposed. The degraded aspect after biodegradation and the exposure of fillers after mechanical degradation were visualized in micrographs. This study demonstrated that the nanotechnology incorporated in restorative materials, as in composite resin and resin-modified glass ionomer, was important for the superior resistance to biomechanical degradation.


Subject(s)
Composite Resins/chemistry , Dental Restoration Wear , Glass Ionomer Cements/chemistry , Nanostructures , Biofilms , Biotransformation , Materials Testing , Microscopy, Electron, Scanning , Streptococcus mutans/metabolism , Surface Properties
3.
Oper Dent ; 39(3): E109-17, 2014.
Article in English | MEDLINE | ID: mdl-24289802

ABSTRACT

OBJECTIVES: The aim of this in vitro study was to investigate the effect of chemical degradation on the surface roughness (Ra) and hardness (Knoop hardness number [KHN]) of nano restorative materials. METHODS: Disc-shaped specimens (5-mm diameter; 2-mm thick) of Filtek Z350 and TPH Spectrum composites and the Vitremer and Ketac Nano light-curing glass ionomer cements were prepared according to the manufacturers' instructions. After 24 hours, polishing procedures were performed and initial measurements of Ra and KHN were taken. The specimens were divided into 12 groups (n=10) according to material and storage media: artificial saliva, orange juice, and Coca-Cola. After 30 days of storage, the specimens were reevaluated for Ra and KHN. The pH values of the storage media were measured weekly. Data were tested for significant differences by repeated-measures three-way analysis of variance and Tukey tests (p<0.05). RESULTS: Composites were found to present lower roughness values and higher hardness values than the ionomeric materials under all storage conditions. After degradation, the KHN of all experimental samples decreased significantly, while the Ra of the ionomeric materials increased, depending on the media, with a markedly negative impact of Coca-Cola and orange juice. There was no difference among the storage media for Filtek Z350 with regard to the KHN values. Nanofillers did not show any influence on the roughness and hardness of resin-modified glass ionomer cements and resin composites concerning their degradation resistance.


Subject(s)
Composite Resins/metabolism , Dental Restoration Wear , Glass Ionomer Cements/metabolism , Magnesium Oxide/metabolism , Nanostructures , Polycarboxylate Cement/metabolism , Zinc Oxide/metabolism , Dental Restoration, Permanent/methods , Hardness , Humans , In Vitro Techniques , Light-Curing of Dental Adhesives , Surface Properties
4.
Oper Dent ; 37(5): 509-17, 2012.
Article in English | MEDLINE | ID: mdl-22433031

ABSTRACT

Nanofillers have been incorporated into glass ionomer (GI) restorative materials to improve their mechanical and surface properties. The aim of this present laboratory study was to compare the superficial roughness (Ra) of nanofilled GI (Ketac N100) with that of conventional GI (Fuji IX GP), resin-modified GI (Vitremer), and a nanofilled resin composite (Filtek Supreme) after pH cycling and toothbrush abrasion. Ten specimens of each material were made using Teflon molds, which were polished using aluminum-oxide abrasive disks. Three measurements of Ra were made of each specimen to serve as baseline values. The specimens were submitted to pH cycling for 10 days in a demineralization solution for six hours (pH 4.3) and were then stored in remineralization solution for 18 hours (pH 7.0). Ra measurements were recorded after the pH cycling. Specimens were then submitted to toothbrush abrasion in a brushing machine with a 200g load for 30,000 cycles at 250 cycles/min. The Ra values were then recorded. The surface morphology of specimens from each group was analyzed using a scanning electron microscope. Data were analyzed by analysis of variance, Tukey, and t-tests. After toothbrushing, only Fuji IX GP (1.10 ± 0.80) showed Ra values that were statistically different from those of the other materials evaluated. Ketac N100 (0.68 ± 0.16) showed intermediate Ra values, but it did not differ statistically from the results associated with Vitremer (1.04 ± 0.46) and Filtek (0.30 ± 0.15). Ketac N100 showed intermediate values of superficial roughness among the conventional glass ionomer cement, resin-modified glass ionomer cements, and the nanofilled resin after chemical and mechanical degradation.


Subject(s)
Composite Resins/chemistry , Glass Ionomer Cements/chemistry , Nanocomposites/chemistry , Nanoparticles/chemistry , Aluminum Oxide/chemistry , Dental Polishing/instrumentation , Humans , Hydrogen-Ion Concentration , Materials Testing , Microscopy, Electron, Scanning , Stress, Mechanical , Surface Properties , Time Factors , Toothbrushing/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL