Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Phys Rev Lett ; 124(23): 232502, 2020 Jun 12.
Article in English | MEDLINE | ID: mdl-32603173

ABSTRACT

We report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden nonunique ß-decay transition ^{137}Xe(7/2^{-})→^{137}Cs(7/2^{+}). The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultralow background environment of EXO-200, together with dedicated source deployment and analysis procedures, allowed for collection of a pure sample of the decays, with an estimated signal to background ratio of more than 99 to 1 in the energy range from 1075 to 4175 keV. In addition to providing a rare and accurate measurement of the first-forbidden nonunique ß-decay shape, this work constitutes a novel test of the calculated electron spectral shapes in the context of the reactor antineutrino anomaly and spectral bump.

2.
Phys Rev Lett ; 123(16): 161802, 2019 Oct 18.
Article in English | MEDLINE | ID: mdl-31702371

ABSTRACT

A search for neutrinoless double-ß decay (0νßß) in ^{136}Xe is performed with the full EXO-200 dataset using a deep neural network to discriminate between 0νßß and background events. Relative to previous analyses, the signal detection efficiency has been raised from 80.8% to 96.4±3.0%, and the energy resolution of the detector at the Q value of ^{136}Xe 0νßß has been improved from σ/E=1.23% to 1.15±0.02% with the upgraded detector. Accounting for the new data, the median 90% confidence level 0νßß half-life sensitivity for this analysis is 5.0×10^{25} yr with a total ^{136}Xe exposure of 234.1 kg yr. No statistically significant evidence for 0νßß is observed, leading to a lower limit on the 0νßß half-life of 3.5×10^{25} yr at the 90% confidence level.

3.
Phys Rev Lett ; 121(7): 071801, 2018 Aug 17.
Article in English | MEDLINE | ID: mdl-30169081

ABSTRACT

This Letter reports the first results of a direct dark matter search with the DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg capacity. The LAr is viewed by an array of PMTs, which would register scintillation light produced by rare nuclear recoil signals induced by dark matter particle scattering. An analysis of 4.44 live days (fiducial exposure of 9.87 ton day) of data taken during the initial filling phase demonstrates the best electronic recoil rejection using pulse-shape discrimination in argon, with leakage <1.2×10^{-7} (90% C.L.) between 15 and 31 keV_{ee}. No candidate signal events are observed, which results in the leading limit on weakly interacting massive particle (WIMP)-nucleon spin-independent cross section on argon, <1.2×10^{-44} cm^{2} for a 100 GeV/c^{2} WIMP mass (90% C.L.).

4.
Phys Rev Lett ; 120(7): 072701, 2018 Feb 16.
Article in English | MEDLINE | ID: mdl-29542972

ABSTRACT

Results from a search for neutrinoless double-beta decay (0νßß) of ^{136}Xe are presented using the first year of data taken with the upgraded EXO-200 detector. Relative to previous searches by EXO-200, the energy resolution of the detector has been improved to σ/E=1.23%, the electric field in the drift region has been raised by 50%, and a system to suppress radon in the volume between the cryostat and lead shielding has been implemented. In addition, analysis techniques that improve topological discrimination between 0νßß and background events have been developed. Incorporating these hardware and analysis improvements, the median 90% confidence level 0νßß half-life sensitivity after combining with the full data set acquired before the upgrade has increased twofold to 3.7×10^{25} yr. No statistically significant evidence for 0νßß is observed, leading to a lower limit on the 0νßß half-life of 1.8×10^{25} yr at the 90% confidence level.

5.
Phys Rev Lett ; 109(3): 032505, 2012 Jul 20.
Article in English | MEDLINE | ID: mdl-22861843

ABSTRACT

We report on a search for neutrinoless double-beta decay of 136Xe with EXO-200. No signal is observed for an exposure of 32.5 kg yr, with a background of ∼1.5×10(-3) kg(-1) yr(-1) keV(-1) in the ±1σ region of interest. This sets a lower limit on the half-life of the neutrinoless double-beta decay T(1/2)(0νßß)(136Xe)>1.6×10(25) yr (90% C.L.), corresponding to effective Majorana masses of less than 140-380 meV, depending on the matrix element calculation.

6.
Phys Rev Lett ; 107(21): 212501, 2011 Nov 18.
Article in English | MEDLINE | ID: mdl-22181874

ABSTRACT

We report the observation of two-neutrino double-beta decay in (136)Xe with T(1/2) = 2.11 ± 0.04(stat) ± 0.21(syst) × 10(21) yr. This second-order process, predicted by the standard model, has been observed for several nuclei but not for (136)Xe. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrinoless double-beta decay, the most sensitive probe for the existence of Majorana particles and the measurement of the neutrino mass scale.

7.
Radiat Prot Dosimetry ; 120(1-4): 499-502, 2006.
Article in English | MEDLINE | ID: mdl-16822778

ABSTRACT

The PICASSO project is a cold dark matter (CDM) search experiment relying on the superheated droplet technique. The detectors use superheated freon liquid droplets (active material) dispersed and trapped in a polymerised gel. This detection technique is based on the phase transition of superheated droplets at about room temperature and ambient pressure. The phase transition is induced by nuclear recoils when an atomic nucleus in the droplets interacts with incoming subatomic particles. This includes CDM particles candidate as the neutralino (a yet-to-discover particle predicted in extensions of the standard model of particle physics). Simulations performed to understand the detector response to neutrons and alpha particles are presented along with corresponding data obtained at the Montreal Laboratory.


Subject(s)
Computer-Aided Design , Cosmic Radiation , Extraterrestrial Environment , Linear Energy Transfer , Microbubbles , Models, Chemical , Thermoluminescent Dosimetry/instrumentation , Computer Simulation , Dose-Response Relationship, Radiation , Equipment Design , Equipment Failure Analysis , Materials Testing , Radiation Dosage , Reproducibility of Results , Sensitivity and Specificity , Surface Properties , Thermoluminescent Dosimetry/methods
8.
Radiat Prot Dosimetry ; 120(1-4): 495-8, 2006.
Article in English | MEDLINE | ID: mdl-16644961

ABSTRACT

The PICASSO experiment investigates the presence and nature of dark matter in the Universe. The experiment is based on the detection of acoustic signals generated in explosive phase transitions induced by dark matter particles. This technique is an alternative more traditional detection technique like scintillation and ionisation, which are largely employed for dark matter search. One of the main advantages of this technique, besides its sensitivity to very low nuclear recoil energies (few keV), is its excellent background suppression features. A pilot experiment consisting of six superheated droplet detectors (40 g of active mass) is presently taking data at the Sudbury Neutrino Observatory (SNO) at a depth of 2000 m. We discuss the operation, calibration and data acquisition of the experiment and also the ongoing work to increase the sensitivity and the active mass of the detectors.


Subject(s)
Cosmic Radiation , Extraterrestrial Environment , Hot Temperature , Microbubbles , Thermoluminescent Dosimetry/instrumentation , Dose-Response Relationship, Radiation , Equipment Design , Equipment Failure Analysis , Gels/chemistry , Gels/radiation effects , Materials Testing , Radiation Dosage , Reproducibility of Results , Sensitivity and Specificity , Surface Properties , Thermoluminescent Dosimetry/methods
9.
Rev Sci Instrum ; 85(9): 095114, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25273779

ABSTRACT

We describe a system to transport and identify barium ions produced in liquid xenon, as part of R&D towards the second phase of a double beta decay experiment, nEXO. The goal is to identify the Ba ion resulting from an extremely rare nuclear decay of the isotope (136)Xe, hence providing a confirmation of the occurrence of the decay. This is achieved through Resonance Ionization Spectroscopy (RIS). In the test setup described here, Ba ions can be produced in liquid xenon or vacuum and collected on a clean substrate. This substrate is then removed to an analysis chamber under vacuum, where laser-induced thermal desorption and RIS are used with time-of-flight mass spectroscopy for positive identification of the barium decay product.

10.
Rev Sci Instrum ; 82(10): 105114, 2011 Oct.
Article in English | MEDLINE | ID: mdl-22047336

ABSTRACT

A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon time projection chamber of EXO-200. The pump, using sprung polymer gaskets, is capable of pumping more than 16 standard liters per minute of xenon gas with 750 Torr differential pressure.

11.
Rev Sci Instrum ; 81(11): 113301, 2010 Nov.
Article in English | MEDLINE | ID: mdl-21133463

ABSTRACT

We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating (148)Gd onto a silicon α-particle detector and vapor depositing a layer of BaF(2) over it. (144)Sm recoils from the alpha decay of (148)Gd are used to dislodge Ba(+) ions from the BaF(2) layer and emit them in the surrounding environment. The simultaneous detection of an α particle in the substrate detector allows for tagging of the nuclear decay and of the Ba(+) emission. The source is simple, durable, and can be manipulated and used in different environments. We discuss the fabrication process, which can be easily adapted to emit most other chemical species, and the performance of the source.